Electric Wiring Cables/ Flexible Electrical Wire

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
10000 m
Supply Capability:
1000000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specifications of  Electric Wiring Cables/ Flexible Electrical Wire  

PVC sheath solid conductor electrical wire 
ISO 9001-2008 
Voltage: 450/750V 
Cross section:1.0mm2 to 500mm2 
OEM acceptance

Solid copper conductor  Electric Wiring Cables/ Flexible Electrical Wire 

 

1.electrical wire is usually PVC insulated wire

PVC insulation no-sheathed general purpose electrical wire,single core,solid

2.sheathed round wires:

copper(aluminum)conductor pvc insulated pvc sheathed solid wires

copper(aluminum)conductor pvc insulated pvc sheathed flexible wires

Sizes:0.5-185mm2

3.products can be produced and provided accroding to standard G/T5023,IEC60227,BS6004,JB8734.

Standard:

GB/T5023.1-1997  450/750V or below PVC insulated electric wires.

GB/T5023.1-1997 is identical to IEC227,models are the same,can be produced according to customers requirement.

Using purpose:

4. used for AC rated voltage 450/750V and below for the followings:

lighting,electrical installation,the connection between instrumention and telecomunication equipment

 

Technical Data Sheet of  Electric Wiring Cables/ Flexible Electrical Wire 

Class 2 Conductor

Nominal
sectional area
mm2

Conductor
No/Dia.
mm

Nominal
Insulated thick
mm

Max overall
Dia.
mm

Condcutor
Resistance at
20

Weight
Kg/km

Cu

Al

Cu

Al

1.5

1/1.38

0.7

3.3

12.1

-

19.2

-

2.5

1/1.78

0.8

3.9

7.41

11.8

30.8

15.0

4

1/2.25

0.8

4.4

4.61

7.39

45.5

21.0

6

1/2.76

0.8

4.9

3.08

4.91

65.0

29.0

10

7/1.35

1.0

7.0

1.83

3.08

110.0

52.0

16

7/1.70

1.0

8.0

1.15

1.91

170.0

70.0

25

7/2.14

1.2

10.0

0.727

1.20

270.0

110.0

35

7/2.52

1.2

11.5

0.524

0.868

364.0

150.0

50

19/1.78

1.4

13.0

0.387

0.641

500.0

200.0

70

19/2.14

1.4

15.0

0.268

0.443

688.0

269.0

95

19/2.52

1.6

17.5

0.193

0.320

953.0

360.0

120

37/2.03

1.6

19.0

0.153

0.253

1168.0

449.0

150

37/2.25

1.8

21.0

0.124

0.206

1466.0

551.0

185

37/2.52

2.0

32.5

0.099

0.164

1808.0

668.0

 

 Class 5 Conductor of  Electric Wiring Cables/ Flexible Electrical Wire 

Nominal
sectional area
mm2

Conductor
No/Dia.
mm

Nominal
Insulated thick
mm

Max overall
Dia.
mm

Condcutor
Resistance at
20

Min insulated
resistance at
70MΩ/km

Weight
Kg/km

2.5

9/0.41

0.8

4.2

7.41

0.011

33.0

4

19/0.52

0.8

4.8

4.61

0.009

48.0

6

19/0.64

0.8

5.6

3.08

0.0084

68.0

10

49/0.52

1.0

7.6

1.83

0.0072

115.0

16

49/0.64

1.0

8.8

1.15

0.0062

176.0

25

98/0.58

1.2

11.0

0.727

0.0058

272.0

35

133/0.58

1.2

12.5

0.524

0.0052

384.0

50

133/0.68

1.4

16.5

0.387

0.0051

510.0

70

189/0.68

1.4

16.5

0.268

0.0045

714.0

95

259/0.68

1.

19.5

0.139

0.0035

965.0

120

259/0.76

1.8

22.0

0.153

0.0032

1210.0

150

259/0.85

1.8

25.0

0.124

0.0032

1510.0

 

Pictures of  Electric Wiring Cables/ Flexible Electrical Wire  

Electric Wiring Cables/ Flexible Electrical Wire



Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Now the market professional installation monitoring the construction team how much money a point? , As well as cable patch panels and telephone patch panels how much money a point? Is it distance?
I think it is possible, because in our (old) substation, the cable trench is the drain, the cable erected in the cable bracket.
Q:Why this cable has not yet been certified
The manufacture of wire and cable is completely different from that of most electromechanical products
Q:Is the toilet wire walk on the ground? Are there any hidden dangers?
The proportion of the cross-sectional area of the cable through the embedded pipe is 20%
Q:What is the current good computer configuration on the market? The price of 4000 yuan or so no more than 4000 assembly parts to write down the price Thank you.
A very practical proposal: to your local talent market, a large job fairs, and the best and your professional relevance, to see, look at what positions, pay how? You can also chat with hr, you will understand.
Q:Where should the inner diameter of the plastic tube of the cable be at least the number of times the outer diameter of the cable?
You are not very clear: how to start again? 300μF capacitor is normal? If the sound is normal (very small) after no-load start, the cable and the motor temperature are normal, the coil can be judged to be normal
Q:Wire printed on the word what way to erase
If you need an unqualified wire, you can contact this part
Q:2.5 square copper (green, with the threading tube) can withstand the highest power of several kilowatts,
Should be the line group: lighting a group of 2.5 square millimeters, an ordinary socket a group of 4 square millimeters, air conditioning a group of 6 square millimeters, kitchen and bathroom appliances a group of 4 square millimeters, so that after the down is not enough to put a separate group You say the high-power electrical outlet, the line to the square of the square mm to see your home how high-power electrical appliances, but advise you to use these high-power electrical appliances before the first to determine its current good, More than your home appliance load!
Q:What kind of KVM switch is this configuration below?
Direct selection of reton's 32-port digital KVM, model is: KS-2032C. Fast transmission, wiring is simple. Want to know the price to ask their website on it.
Q:What is the cable for rvv? Is it a power cable or a control cable? What is the cable?
The installation process is a certain requirement, high and low voltage cable bridge should be installed separately as usual, a wall laying vertical pipeline (slot) or installation equipment, the power distribution between the depth of D1 = 1200 ~ 1500mm; weak Between the deep distance from the D2 = 1100 ~ 1400mm more reasonable. The length L1 and L2 between the power distribution and the weak can be determined according to how much electrical equipment and pipelines (slots) are installed in the room. "Civil building electrical design specifications" proposed "shaft size in addition to meet the wiring spacing and terminal box, distribution box layout must be the size, but also in the box before the left not less than 0.8m operation, maintenance distance" requirements. In the weak equipment, the operation and maintenance distance is not specified in the provisions of the Code for Electrical Design of Civil Buildings, but it should not be less than 0.8m. Cable to wear steel pipe wiring, should be reserved in the floor steel pipe, wiring should be completed after the plug fire fire blocking material. Cable bridge installation should be horizontal, the maximum sag should not be greater than 10 mm; proposed separate installation
Q:Cable YJV-3 * 70 + 2 * 35 general wear large SC tube? Ask you.
Yes, it is more conducive to the protection of the battery, but if no power out of power, the data can not be saved ah, and you have to put the battery on a regular charge

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range