Range summary

The EosG range of gel technology batteries offers outstanding performance including  a 15+ years design life .

The EosG series batteries is designed based on the Eos series.

Using the polymer gel electrolyte .

Built to the highest standards and compliant with the latest IEC60896-21/22 standard .

This range also offers 100% capacity out-of-the-box and is capable of handling deep discharges for complete peace of mind. The use of flexible  connectors and the ability to be installed  both horizontally and vertically allows for multiple installation possibilities.

Technical features

  • Above 15 years designed life

  • Reliable post sealing structure

  • Excellent charging acceptant ability

  • Excellent performance at extreme high  and low temperature

  • Low self-discharge ability

  • Flexible and convenient installation  with slinky outside looking

 

 

 

Type:

  EosG1250

Voltage:

  2V

Nominal Capacity:

  1250Ah(C10)  1250Ah(10 hours rate:)

Length:

  225mm

Width:

  229mm

Height:

  555mm

Height  with termial:

  566mm

Weight:

  80Kg

Compliant standards

    • IEC60896-21/22

    • BS6290 part 4

    • Telcordia SR4228

    • Eurobat guide

    • UL

    • Manufactured under system ISO9001(TUV)                                          

    Battery installation compliant with:

    • EN 50272-2 or local equivalents

    Main applications

    • Correspondence exchange and transmission system

    • Mobile communication system

    • Power plant and power transformer system

    • Navigation and signaling system

    • Solar energy system

    • Radio and broadcasting station

    • Emergency lighting system

    Products characteristics:

    • Plate special patent calcium and tin  lead alloy and thick plate design

    • Container ABS(V0 optional)

    • Separator AGM

    • Valve EPDR

    • Electrolyte using the polymer gel electrolyte

    • Terminal M8 copper core posts

    FAQ

    What is sulfation of batteries?

    Sulfation is the formation or deposit of lead sulfate on the surface and in the pores of the active material of the batteries' lead plates. If the sulfation becomes excessive and forms large crystals on the plates, the battery will not operate efficiently and may not work at all. Common causes of battery sulfation are standing a long time in a discharged condition, operating at excessive temperatures, and prolonged under or over charging.

    How long a battery can last?

    The service design life of a battery are vary considerably with how it is used, how it is maintained and charged, temperature, and other factors.

    Do batteries self-discharge when not in use?

    All batteries, regardless of their chemistry, self-discharge. The rate of self-discharge depends both on the type of battery and the storage temperature the batteries are exposed to. However, for a good estimate, Narada batteries self-discharge approximately 4% per week at 80ĄăF.

     

Q:What is a maintenanceable battery?
Maintenance-free battery due to its own structure on the advantages of electrolyte consumption is very small, in the life of the basic need not add distilled water.
Q:Battery 200ah / 104 what does that mean?
Lead-acid battery nominal voltage is 2V / (each or monomer), but in fact will be higher than 2V, so the actual use and charging equipment for the matching will use 104, also useful 103, also useful 108 Only.
Q:What is the difference between a maintenance-free battery and a conventional battery?
As a result of maintenance-free batteries using lead-calcium alloy grille, the amount of water generated when charging less water evaporation, coupled with the shell with a sealed structure, the release of sulfuric acid gas is also very small, so it compared with the traditional battery, With no need to add any liquid, the wiring pile head, wire and body corrosion less anti-overcharge capacity, starting current, power storage time is long, by the car people welcome.
Q:How does the battery increase the voltage?
Chemical energy can be converted into electrical energy device called chemical battery, generally referred to as the battery. After discharge, the internal active material can be regenerated by charging - the electrical energy stored as chemical energy; chemical energy can be converted to electrical energy again when the discharge is required. This type of battery is called a battery (Storage Battery), also known as secondary battery.
Q:How to repair the battery?
Connect the positive and negative output of the repair instrument to the positive and negative pole of the battery, open the repair instrument, repair the battery. The first repair time should be no less than 48 hours.
Q:What are the hazards of battery over discharge?
Crystalline conductivity is poor, and bulky, will clog the pores of the battery plate, affecting the battery electrolyte penetration and exchange, but also further increase the battery resistance, a long time will prevent the battery power and chemical energy Of the reversible conversion, resulting in poor recovery of the battery charge, the battery was seriously damaged, or even unable to repair until scrapped.
Q:What kind of battery is divided into?
Maintenance-free battery due to its own structure on the advantages of electrolyte consumption is very small, in the life of the basic need not add distilled water. It also has a shock, high temperature, small size, self-discharge characteristics of the general life is generally ordinary Twice the battery. There are two kinds of maintenance-free batteries on the market.
Q:Lead-acid battery how to maintain?
After passing the test, cover the exhaust cutting, pay attention to restore the filler, cover the battery cover, if the cover is glued, then glue bonding.
Q:Maintenance-free battery how to detect it?
When using a maintenance-free battery, it is easy to think that maintenance-free is the idea that no maintenance is required. Maintenance-free Although maintenance costs and times can be reduced, but for the appearance of the clean-up is essential, so that "maintenance-free" more point to the battery inside.
Q:What battery does the van use?
General use of lead-acid batteries. Electrode is mainly made of lead and its oxide, the electrolyte is a sulfuric acid solution of a battery. English: Lead-acid battery Discharge state, the main component of the cathode is lead dioxide, the main component of the negative lead; charge state, the main components of the positive and negative are lead sulfate. Divided into exhausted batteries and maintenance-free lead-acid batteries.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords