Specifications

           XKGKL current limiting reactor is to connect the
system in series to improve system impedance,
and it can low short-circuit                

Model

Rated current A

Reactance rate %

Reactance Ω

Short time current kA

Single phase capacitance kvar

Single phase cost 75°C

Pedestal diameter Dc Mm

Weight kg

Installation suggestion

6kV Dry-type air-core current limiting reactor

XKGKL-6-4000-4

4000

4

0.0364

100.0

554

8600

1430

825

Two superposition and one horizontal installation

XKGKL-6-4000-12

12

0.104

33.33

1664

17875

1480

1204

10kV Dry-type air-core current limiting reactor

XKGKL-10-4000-12

4000

4

0.058

100.00

924

11506

1440

960

Two superposition and one horizontal installation

XKGKL-10-4000-12

12

0.173

33.33

2771

22561

1740

1833

35kV Dry-type air-core current limiting reactor

XKGKL-35-1500-12

1500

4

0.539

37.5

1212

12.4

1510

1280

horizontal installation

XKGKL-35-1500-12

12

1.616

12.5

3637

23

2110

2380


Q:What is the difference between power supply and distribution
Power supply and distribution is part of the use of general by the Architectural Design Institute of electrical professional
Q:Transmission and transformation equipment
Transmission and transformation of basic electrical equipment, including the main wire, transformers, switchgear, high voltage insulators, etc.
Q:Transmission lines are not electrical equipment?
If you are satisfied, please accept it as a satisfactory answer
Q:Rural high voltage transmission line equipment ownership
the transformer can be what, look at the role of electrical appliances can be
Q:An introduction to the interpretation of flexible AC transmission systems
synchronous compensator (STATCOM), reactive power distribution is mainly used to improve the system, to adjust voltage and improve the voltage stability of the system;
Q:What are the distribution network equipment
The transmission function of the power plants issued by the electricity to power consumption areas, or between adjacent grid power to send each other
Q:DC transmission equipment
Power supply operation of power plant and substation in nowadays are used in DC power supply, it provides power for the control of the load and power load and DC emergency lighting load, is the foundation of modern electric power system control and protection
Q:What are the two power distribution equipment?
Such as generator, transformer, circuit breaker, isolating switch, bus, power cable and transmission lines, etc..
Q:High and low voltage distribution equipment
Low voltage distribution equipment: low voltage distribution panel, switch cabinet, switch board, lighting box, power box and motor control center.
Q:What is the power equipment in the distribution room?
which is mainly used for the distribution of the electric energy of the low-voltage users, and the utility model is provided with a medium voltage input line (a small number of outlets)

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Related keywords