AGM Battery the Eos Series Battery Eos-500

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
10 unit
Supply Capability:
100000 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Range summary


                                 

The Eos range products are designed as standby power for communication, power, military and broadcast and television system. Elegant design with high energy density, latest improved technology are adopted in this series,design life is 15+ years.

The Eos range batteries are ensured the quality with NARADA's QA system according to the ISO9001 standard.

Technical features


  • AGM technology is applied.

  • 15+ years design life under floating application and cycle life is above 1200 at 80% DOD under temperature 25oC.

  • Reliable seal performance, no acid spillage, recombination efficiency reach 99.9%

  • Initial capacity above 100%, the remaining capacity above 94% after storage for 3 months (25oC)

  • low float charge voltage. design (2.25V/cell, 25oC), extremely consistent float charge voltage

  • Flexible connectors and convenient installation

 

Type:

  Eos-500

Voltage:

  2V

Nominal Capacity:

  500Ah(C10)  500Ah(10 hours rate:)

Length:

  194.5mm

Width:

  184.5mm

Height:

  360.5mm

Height        with termial:

  372mm

Weight:

  29.5Kg

 

Compliant standards

  • IEC60896-21/22

  • BS6290 part 4

  • Telcordia SR4228

  • Eurobat guide

  • UL

  • Manufactured under system ISO9001(TUV)

Battery installation compliant with:

  • EN 50272-2 or local equivalents

Main applications

  • Telecommunications

  • Uninterruptible power supply (UPS)

  • Other applications to provide integrated stored energy system

Products characteristics:

  • Recommended float charge voltage for 2V battery: 2.25Vpc at 77oF(25oC)

  • Self discharge rate :< 2% per month at 77oF(25oC)

  • Design life: 15+ years at 77oF(25oC)

  • Shelf life: 6 months at 68oF(20oC)

  • Valve regulated system, no water addition needed

FAQ

What is a AGM (Absorbed Glass Mat )Battery?

The newer type of sealed nonspillable maintenance free valve regulated battery uses "Absorbed Glass Mats", or AGM separators between the plates. This is a very fine fiber Boron-Silicate glass mat. These type of batteries have all the advantages of gelled, but can take much more abuse. These are also called "starved electrolyte.Ąą Just like the Gel batteries, the AGM Battery will not leak acid if broken.

What are the advantages of the AGM battery?

The advantages of AGM batteries are no maintenance, sealed against fumes, hydrogen, leakage, or non-spilling even if they are broken, and can survive most freezes. AGM batteries are "recombinant" ¨C which means the Oxygen and Hydrogen recombine inside the battery. These use gas phase transfer of oxygen to the negative plates to recombine them back into water while charging and prevent the loss of water through electrolysis. The recombining is typically 99+% efficient, so almost no water is lost. Charging voltages for most AGM batteries are the same as for a standard type battery so there is no need for special charging adjustments or problems with incompatible chargers or charge controls. Since the internal resistance is extremely low, there is almost no heating of the battery even under heavy charge and discharge currents. AGM batteries have a very low self-discharge rate (from 1% to 3% per month). So they can sit in storage for much longer periods without charging. The plates in AGM's are tightly packed and rigidly mounted, and will withstand shock and vibration better than any standard battery.


 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How should the battery be well maintained?
So the proposed owners if the vehicle long-term stop, but also 2 to 3 months for the battery for a charge.
Q:What are the advantages of maintenance-free batteries?
Maintenance-free battery because of its normal charging voltage, the electrolyte only produce a small amount of gas, so throughout the use of the need for the addition of distilled water, in the normal charging system, do not need to remove the charge from the removal. But in the maintenance of the proportion of its electrolyte should be checked.
Q:Battery 200ah / 104 what does that mean?
This should be refers to 2V200AH battery 104, power with the 220V.
Q:80ah how much battery storage capacity?
0AH storage is 80AH ah If the actual storage capacity will have to see the brand. I have seen 100AH only 24 pound. This is not even 60AH.
Q:How to determine the battery is good or bad?
Instrument test: the general use of battery discharge tester, the test instrument two positive and negative clamp were holding the battery positive and negative electrodes, press the test button to observe the test instrument instructions.
Q:What is the meaning of the battery above 12v65Ah?
12V represents the rated voltage. 65Ah indicates that the battery capacity (ie 1 ampere current can be used for 65 hours).
Q:What are the hazards of battery over discharge?
Crystalline conductivity is poor, and bulky, will clog the pores of the battery plate, affecting the battery electrolyte penetration and exchange, but also further increase the battery resistance, a long time will prevent the battery power and chemical energy Of the reversible conversion, resulting in poor recovery of the battery charge, the battery was seriously damaged, or even unable to repair until scrapped.
Q:What is a maintenanceable battery?
Maintenance-free battery due to its own structure on the advantages of electrolyte consumption is very small, in the life of the basic need not add distilled water.
Q:What battery does the van use?
The most obvious feature of lead-acid batteries is the top of the plastic cover can be unscrewed, there are ventilation holes above. These fillers are used to fill pure water, check the electrolyte and the use of exhaust gas. In theory, lead-acid batteries need to check the density of each electrolyte and the level of liquid, if there is a need to add distilled water. But with the upgrading of battery manufacturing technology, lead-acid battery development for the lead-acid maintenance-free batteries and colloidal maintenance-free batteries, lead-acid batteries do not need to add electrolyte or distilled water. Mainly the use of positive electrode to produce oxygen can be absorbed in the negative oxygen cycle, to prevent water reduction. Lead-acid water batteries are mostly used in tractors, tricycles, car start, etc., and maintenance-free lead-acid battery wider range of applications, including uninterruptible power supply, electric vehicle power, electric bicycle batteries. Lead-acid batteries according to the application needs to be divided into constant current discharge (such as uninterruptible power supply) and instantaneous discharge (such as car to start the battery).
Q:The role of the battery?
Battery is widely used, can be used for ups, electric cars, scooters, cars, wind energy solar systems, security, and so on.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range