9000-24000BTU Split Wall Mounted Hybrid Solar Air Conditioner (CE,RoHS,CB,SASO Certified)

Ref Price:
$329.60 - 721.00 / set
Loading Port:
Ningbo
Payment Terms:
L/C,T/T
Min Order Qty:
1 Piece set
Supply Capability:
10000 Pieces per Month set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Split Wall Mounted Hybrid Solar Air Conditioner

 

1. Our factory is an manufacture of solar air conditioner, solar air conditioning, solar air conditioning system, plate type solar air condtioner, vacuum tube type solar air condtioner, we are an professional OEM manufacturer For soalr Air Conditioner, CE CB SASO UL SAA SONCAP RoHS Certifications ISO9001 Passed.

2. Specification for split wall mounted  type: 9000Btu, 12000Btu, 18000Btu, 20000Btu, and 24000Btu.

3. solar collector: vacuum tube or flat plate type

4. Power supply: 110-240V

5. Frequency:  220V/50HZ or 220V/60HZ

6. Refrigerant: R22, R407C or R410A

7.Choice for function: cooling only or cooling & heating

8. Minimum order: 10 sets

9. Sample: available.

 

 hybrid solar air conditioner  sysem  

 

1.The solar air-conditioner is driven by electricity and with solar energy as an auxiliary power. The two kinds of energy work complementally in accordance with principles of fluid dynamics.         

 2.The solar air-conditioner combines the absorption working system to compression system by using environmental-friendly media in cooling and heating on the basic of traditional air-conditioner technology to achieve energy-saving and environment protection.

3. It adopts vacuum tube solar collector which is with high performance of absorption and low reflection ratio.    

 

 

Technical spefic

 

Model No. TKF(R)-26GW TKF(R)-35GW  TKF(R)-52GW TKF(R)-60GW TKF(R)-72GW
Cool capacity9000BTU12000BTU18000BTU20000BTU24000BTU
Heat capacity10000BTU13000BTU18800BTU22000BTU27000BTU

 

  

FAQ

Q1:Why is it important to use home air conditioner filters?

A:Without them you can clog up vital parts of the heating or cooling components that can be difficult to clean out and can cause severe damage that will be much more expensive to repair than the inconvenience of replacing a filter once a month.

 

Q2:What is VRF Air Conditioning System?

A:VRF air-conditioning systems owe their growing popularity to their ability to meet a wide range of requirements.

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to connect household air conditioning pressure gauge
1) check for the temperature of the fluid tube and muffler and condensation. Start the air conditioning runs under the condition of refrigeration 20 min, if any condensation on the outdoor unit back to the valve and the muffler, muffler fingered temperature was lower than that for the temperature of the fluid pipe, shows refrigerant in the system is enough, air conditioning running normally. Has one of following cases, indicates lack of refrigeration: (1) for the liquid condensation tube, muffler condensation; (2) for liquid pipe frost; (3) for liquid tube not dewing cool, muffler, nor too cold; (4) for fluid pipe and trachea is not cool. (2) measure the pressure of the valve in the back. Add the pressure gauge connected to air conditioning low pressure Angle valve inlet, measuring its operation at low pressure, under normal circumstances, when the environment temperature is about 30 ℃, refrigeration operation of low pressure is 0.45 ~ 0.55 Mpa, in heat pump air conditioning heating runtime should be 1.8 Mpa, if under the pressure, shows lack of refrigerant. The lower the pressure, the greater the leakage. If the basic pressure, explain refrigerant has. (3) fill nitrogen pressure (1.5 Mpa nitrogen filling the), observe the four two connecting pipe joint, gas liquid valve stem, and whether there is oil stains in areas such as the liquid mouth. There are oil stains for leaks. (4) using the leak detector to find the general part, and then coated with soap and water, if there are air bubbles appeared, to be funnelled namely. (5) of the heat pump air conditioning indoor unit and the connection part of pipe leak detection should be under the heating operation state, because of the inspected parts under high pressure, easy to find funnelled.
Q:How long does it take to add freon home air conditioning?
In theory is 1 year to 2 years Also depends on the frequency of use.Don't have to, if not leak, use how long time is maybe.
Q:Air conditioning power consumption how to calculate
Power consumption is to basically see the power of compressor, the compressor power = refrigerating capacity/energy consumption ratio, the general air conditioning energy consumption ratio is greater than 3, so 1 piece of electric power is 735 w, general data 1.5 horse power is the power consumption of about 1100 watts 735 * 1.5, which is about 1 hour and 1.1 KWH, in addition to the compressor, and a fan or other motors require electricity, a total of 1 hour is 1.2 degrees or so. The most simple way to look at the instructions on the input power is how many kilowatts of power, the power consumption is 1 hour
Q:What is the best air conditioning performance.
Variable frequency and constant speed machine: the working principle of the frequency converter compressor is always start non-stop, through different rotation speed to output different sizes of cold/heat, cold/heat, constant speed machine is a constant output depends on the compressor start and stop to control the temperature. The greatest characteristic of frequency converter, therefore, it is quiet, no compressor start and stop the mechanical noise, 2 it is accurate to 0.5 degrees, the temperature control and constant speed machine control range is 2 degrees, so the frequency conversion machine is especially suitable for use in the bedroom. Due to the frequency changer the price is expensive, decided to other room whether choose according to economic conditions. About energy-saving frequency converter, frequency converter with constant speed machine working mode is different, can't absolutely more energy-saving, frequency converter is used more long time to reflect and energy saving, so the energy-saving sex just select one of the reference factors of frequency converter, is not the main factor. Eer level low frequency changer is not as good as level high constant speed machine and energy saving.
Q:How to choose a good air conditioning
The choice of constant speed with frequency conversion Home has constant speed and variable frequency air conditioning, compared to both the advantage of frequency conversion air conditioning: One is energy saving 2 it is comfortable Third, low noise Four is cooling and heating quickly. 5 it is low voltage startup Six is ultra-low temperature (15 ℃), low temperature heating effect is better. Under low temperature, the frequency conversion air conditioning can improve automatic compressor operation frequency, ensure the better heating effect, it is hard to start and fixed frequency air conditioning compressor under ultra-low temperature. In addition, frequency conversion air conditioning is the machine long life, stable operation, environmental protection and other advantages.
Q:What is the latest technology air conditioning?
The principle has no technology breakthrough. Frequency converter should be compared to constant speed machine advanced technology.
Q:Air conditioning use how long and snow?
If it is newly bought 1 year commonly ~ but want to see you the last time I added many generalisations
Q:What is the air conditioning air filter
Air conditioning filters are generally two kinds of normal and activated carbon series, ordinary air-conditioning filter, usually by a specific environmental protection filter material processed after folding, mostly white layer can also be used for other colors. Series air conditioner filter, activated carbon (non-woven) composite was made by two sides not cloth stuffed with tiny particles made of activated carbon, activated carbon filter cloth made of air conditioning filter and deep processing. Ordinary air-conditioning filter can suppress dust and particulate matter into the role of the activated carbon air filter series, can be in a very short time, the air passes through the choke section using granular activated carbon itself physical properties, adsorption air other tiny and more harmful substances. Filter material generally refers to the air contains impurities, particles, industrial waste gas and dust, pollen, bacteria, etc., with filter can prevent them from entering the air conditioning system air conditioning system,
Q:Why are some called the central air conditioning air conditioning?
Central air conditioning and central air-conditioning: refers to set of air conditioning heat and cold source machine to supply the dispersed air conditioning supply of cold and heat source system. Compared with the decentralized air conditioning, has high thermal efficiency, low price, convenient management. Popular said, relative to household air conditioner, central air conditioning is by one or a few big air conditioning unit concentrated provide cold and heat source, and then through the form of hot air or hot water will be these cold quantity or heat to each room.
Q:Open the wastage of the dehumidification function of air conditioning for a long time
1. The difference is that dehumidification relative to the refrigeration, air volume small, the working frequency is low, open dehumidification function of air conditioning for a long time damage is not big. 2.1 we contact with the air is a mixture of dry air and water vapor, under certain conditions of temperature, 1 kg dry air can let of steam is limited, when reach perfection, we referred to as the saturation state. The state of air dry bulb temperature, wet bulb temperature, dew point temperature is the same. 2.2 the air cooling to the dew point temperature temperature, condensation of water vapor in the air will precipitate, air saturated state. 2.3 air conditioning dehumidification principle that when air flows through the indoor evaporator, as a result of the evaporator cooling effect of cooling air temperature below the dew point temperature, so the part of the water vapor in the air condenses into water precipitation, so as to achieve the aim of dehumidification. 3. The general family expenses air conditioning has a model can be directly set as dehumidification function, if not, you can set for ordinary refrigeration air conditioning mode, switch to a minimum, wind speed set temperature down as far as possible, also can achieve the goal of fast dehumidification.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range