Specifications of Single Core Cable Construction Cable Cire  

PVC sheath solid conductor electrical wire 
ISO 9001-2008 
Voltage: 450/750V 
Cross section:1.0mm2 to 500mm2 
OEM acceptance

Solid copper conductor Single Core Cable Construction Cable Cire 

 

1.electrical wire is usually PVC insulated wire

PVC insulation no-sheathed general purpose electrical wire,single core,solid

2.sheathed round wires:

copper(aluminum)conductor pvc insulated pvc sheathed solid wires

copper(aluminum)conductor pvc insulated pvc sheathed flexible wires

Sizes:0.5-185mm2

3.products can be produced and provided accroding to standard G/T5023,IEC60227,BS6004,JB8734.

Standard:

GB/T5023.1-1997  450/750V or below PVC insulated electric wires.

GB/T5023.1-1997 is identical to IEC227,models are the same,can be produced according to customers requirement.

Using purpose:

4. used for AC rated voltage 450/750V and below for the followings:

lighting,electrical installation,the connection between instrumention and telecomunication equipment

 

Technical Data Sheet of Single Core Cable Construction Cable Cire 

Class 2 Conductor

Nominal
sectional area
mm2

Conductor
No/Dia.
mm

Nominal
Insulated thick
mm

Max overall
Dia.
mm

Condcutor
Resistance at
20

Weight
Kg/km

Cu

Al

Cu

Al

1.5

1/1.38

0.7

3.3

12.1

-

19.2

-

2.5

1/1.78

0.8

3.9

7.41

11.8

30.8

15.0

4

1/2.25

0.8

4.4

4.61

7.39

45.5

21.0

6

1/2.76

0.8

4.9

3.08

4.91

65.0

29.0

10

7/1.35

1.0

7.0

1.83

3.08

110.0

52.0

16

7/1.70

1.0

8.0

1.15

1.91

170.0

70.0

25

7/2.14

1.2

10.0

0.727

1.20

270.0

110.0

35

7/2.52

1.2

11.5

0.524

0.868

364.0

150.0

50

19/1.78

1.4

13.0

0.387

0.641

500.0

200.0

70

19/2.14

1.4

15.0

0.268

0.443

688.0

269.0

95

19/2.52

1.6

17.5

0.193

0.320

953.0

360.0

120

37/2.03

1.6

19.0

0.153

0.253

1168.0

449.0

150

37/2.25

1.8

21.0

0.124

0.206

1466.0

551.0

185

37/2.52

2.0

32.5

0.099

0.164

1808.0

668.0

 

 Class 5 Conductor of Single Core Cable Construction Cable Cire 

Nominal
sectional area
mm2

Conductor
No/Dia.
mm

Nominal
Insulated thick
mm

Max overall
Dia.
mm

Condcutor
Resistance at
20

Min insulated
resistance at
70MΩ/km

Weight
Kg/km

2.5

9/0.41

0.8

4.2

7.41

0.011

33.0

4

19/0.52

0.8

4.8

4.61

0.009

48.0

6

19/0.64

0.8

5.6

3.08

0.0084

68.0

10

49/0.52

1.0

7.6

1.83

0.0072

115.0

16

49/0.64

1.0

8.8

1.15

0.0062

176.0

25

98/0.58

1.2

11.0

0.727

0.0058

272.0

35

133/0.58

1.2

12.5

0.524

0.0052

384.0

50

133/0.68

1.4

16.5

0.387

0.0051

510.0

70

189/0.68

1.4

16.5

0.268

0.0045

714.0

95

259/0.68

1.

19.5

0.139

0.0035

965.0

120

259/0.76

1.8

22.0

0.153

0.0032

1210.0

150

259/0.85

1.8

25.0

0.124

0.0032

1510.0

 

Pictures of  Single Core Cable Construction Cable Cire   

1.5mm PVC Insulated Single Core Electric Cable Wire / Single Core Cable Construction Cable Cire



Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the difference between a kbg threading pipe and a PVC threading pipe?
The expression is not very clear, it should be said to wear a tube, if a single wear on the line 100. Outside diameter 60mm.
Q:What is the difference between a trunking and a bridge in a weak construction?
If you are talking about the three-core wire, black - ground brown - line of blue - zero line. If it is 3 plugs, your wire is only 2 lines. Then the yellow received L, black received N. The above is the ground wire.
Q:Fiber optic cable split box, integrated wiring box, cable terminal box, cable transfer box difference
A lot of ways ah! You look at the back of the set-top box, a total of three kinds of interfaces, namely, HDMI digital signal (while transmitting audio and video signals), red and yellow and yellow chicken complex habit of glycosylation moxibustion slim faint handle (red is the right channel, white Is the left channel, the yellow is the video), the color difference signal (red, green and blue, only transmission video), S terminal (single hole four pin, only transmission video). You just put the video to the TV, the audio to the amplifier on the line. . if your amplifier does not have HDMI interface, then put the set-top box HDMI connected to the TV, the set-top box red and white two terminals, connected to the amplifier red and white input terminal, and adjust the amplifier to the appropriate channel The . if your amplifier has HDMI interface, then through the HDMI series on the line, the first amplifier or the first TV will do. . TV set after a lot of them, there is a group of AVOUT output interface, this group of red and white terminals connected to the power amplifier is also OK.
Q:The computer can not open the machine display frequency beyond the scope of the mouse and keyboard do not start can not press F8 how to do
According to the "Power Engineering Cable Design Code" GB-. 5.3.3 only asked for the depth of the cable buried directly: drop the blue skin to the ground depth, not less than 0.7 meters; when located in the roadway or farmland Under the appropriate should be deepened, and should not be less than 1.0 meters. 5.4.3 protected pipe buried in the ground, should meet the requirements under the depth of the pressure and environmental corrosion resistance. Through the uneven settlement of the backfill section and other places to increase the force, it is appropriate to use steel. Another direct burial should be selected armor type.
Q:What is the cable for rvv? Is it a power cable or a control cable? What is the cable?
The operation of the hydraulic pipe is very simple to see it will engage in their own, embedded more simple, and then get the construction site in accordance with the requirements of the drawings put away, tied with tie wire on the OK Mouth up the pipe to use cement bag to prevent good, to prevent the infusion of concrete, so buried even if the end
Q:Buy Taipower c 450P with remote control to add audio and video cable
Cable and cable distinction In fact, "wire" and "cable" and there is no strict boundaries
Q:What is the difference between "wire" and "cable"?
Inkjet printer is not printed, pictorial machine high definition, generally used in the advertising industry, for large outdoor advertising, the nozzle can choose not necessarily the number of installed, the more spray, spray the faster, a nozzle of the general life 1 year.
Q:Seeking the basement of the outer wall piercing the cable after the casing, how to solve the water (200 points online)
To be considered is the Great Wall power line is not long enough, the power is not big enough to see the power on the label, if the 12V to 15A or more I think will be more stable, my Dell machine power cord surprisingly short, but also To buy the extension line again.
Q:What kind of KVM switch is this configuration below?
Wire and cable warranty period is 30 years of national warranty period. But the specific warranty period according to the type of wire and cable and the use of conditions and temperature and applicable methods to determine. General cable maintenance period is about 15 years, but to ensure that the normal use of the environment, such as the amount of temperature is below 70 degrees, but you are more than 70 working environment to use, of course, may not be used for a year. Therefore, the most important thing is to follow the instructions to use.
Q:Wire pipe inlet air switch trip how to do?
The middle of the line is not a problem where there is a problem in the place where the joints check the place of the joints can not do the lines are out to check the time and effort

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range