1.5 HP Cool And Heat Split Air Conditioner/ CE Room Air Conditioner/Wall-mounted Split Type Air Conditioner

Ref Price:
$143.17 - 162.74 / set
Loading Port:
Ningbo,Shanghai or other ports
Payment Terms:
L/C,T/T
Min Order Qty:
150 Sets set
Supply Capability:
9000 Sets per Month set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

 

 

Wall split Air conditioner ( EM Series  )

 

Features:


1) High Efficiency Compressor

2) Hydrophilic Fins & Inner Threads Copper Tube

3)Quiet and Moden Design

4)Remote Control

5)Sleep Operation

6) Washable Filter

7)Wide Voltage Running

8)Option For Auto-restart Function

 

Specifications:

SPEC.123
ModelKFR-25GWKFR-32GWKFR-35GW
Power220/50-60220/50-60220/50-60
capacity                                 (BTU)cooling90001200013000
heating90001200013000
Rated power (kW)cooling0.91.21.3
heating0.91.21.3
Rated current (A)cooling4.35.66.0
heating4.15.36.0
noise[dB(A)] (cooling/heating)indoor<39<41<41
outdoor<50<52<52
dehumidifying capacity(L/h)1.21.51.5
Net dimensions(mm)            indoor745*255*195745*255*195775*260*210
outdoor600*240*490640*260*540755*260*540
Package dimensions(mm)indoor770*295*245770*295*245800*295*265
outdoor690*335*555770*335*600880*335*600
net weight  (kg)indoor91011
outdoor252833
Package weight  (kg)indoor101112
outdoor273035
Air circulation       (m3/h)        cooling420550550
heating420550550
Lording 20'/40'/40H170/320/360130/260/300
110/220/270

 

 

FAQ

Q1:Why is it important to use home air conditioner filters?

A:Without them you can clog up vital parts of the heating or cooling components that can be difficult to clean out and can cause severe damage that will be much more expensive to repair than the inconvenience of replacing a filter once a month.

Q2:What is VRF Air Conditioning System?

A:VRF air-conditioning systems owe their growing popularity to their ability to meet a wide range of requirements.

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Household air conditioning refrigeration there is burning smell
Air conditioning air inlet blockage, leading to the inside of the hot air blow out, heat not to come out, burned the plastic parts. Rule out way is to first check whether the air inlet flow, and then test of the wind outlet is normal with the hand, and listen to whether there is abnormal sound inside the air conditioner.
Q:What is the difference between the central air conditioning and ordinary air conditioning?
Simple to understand is the common air conditioning is a host to an indoor machine, central air conditioning is a host to tow the indoor machine of more than two (2).
Q:Air conditioning separate-bodied air-conditioners installed can higher than indoor machine
General family expenses between the hanging wall of inside and outside the machine "length" not more than 10 meters, "don't greater than 3 m height difference" inside and outside the machine. (different groups have different brands and models)
Q:Household air conditioning classification
According to the feature classification ChanLengXing: suitable for summer is hot and winter is warm, or winter heating enough area. KFR: suitable for summer hot and winter cold area, and should pay attention to choose the heating is greater than the capacity of air conditioning to ensure heating effect. Air conditioning can be divided by function classification, ChanLengXing, KFR and electric auxiliary heating type 3 kinds. ChanLengXing air conditioning refrigeration effect is outstanding, more suitable for use in summer; And KFR air conditioning refrigeration heating dual function, can cool summer cooling, can also be heating in winter to keep warm. Therefore, fall and winter warm air conditioning, will choose KFR air conditioning.
Q:Home air conditioning is not how to use, how long does it need to open it
No rules must be ok But you don't have air conditioning in time will be bad electronic products is always the same
Q:Can adjust indoor air conditioning circulation within the outer loop
With changing behavior of household air conditioner, just have the function of the outer loop. Circulate in general family expenses air conditioning only, and not the function of the outer loop. But in air with function of air conditioner, can introduce outdoor fresh air into the indoor, can have the function of the outer loop. Air conditioning units are usually used in confined space, long time, can make indoor air pollution, even no collateral in fresh air function of air conditioner, air conditioning after a period of time, it is best to open a window ventilated 5 ~ 10 minutes, to ensure the indoor air clean.
Q:Household air conditioner purchase plan
30 flat is generally a square is 200 w, 6000 w. Sitting room + restaurants are better than one to add to the 250 w, 7500 w. 2500 = 1 p, 3 p.
Q:How to add refrigerant home air conditioning
Size tube on the side of each have a hex is air conditioning when switching the self-contained silk snow with, at ordinary times normal and snow is don't have to twist the two inner hexagon self-contained silk, have with the individual is to twist fill the self-contained silk (premise is manufacturer in maintenance mouth without air conditioning to twist a thimble, encounter this kind of air-conditioning system, and snow of connecting pipe connected and then big pipe hexagon self-contained silk just to twist one two laps and snow, tubular, adds to twist back down again and snow kind of connecting pipe.
Q:What is the principle of air conditioning
Home air conditioning Air conditioner after electrify, refrigeration system of refrigerant in low pressure steam in the compressor and compression for high pressure steam back to the condenser. Axial flow fan at the same time in the outdoor air inhaled through the condenser, take away the refrigerant gives off heat, high pressure refrigerant vapor condenses into high pressure liquid. High pressure liquid after filter, throttle body spray into the evaporator, and the corresponding evaporation under low pressure, absorb the heat around. Tubular fan at the same time make the air entering the heat exchange between the finned evaporator, and the cooling after heat air to send to the interior. So indoor air circulation flow unceasingly, achieve the goal of lower temperature. The central air conditioning Totally enclosed compressor crankshaft and special fluoride resistant motor rotor coaxial, mounted on a common seal in the body, when the motor rotation, used by the transformation of the crank connecting rod piston within the cylinder for reciprocating motion. When piston run began after descending to the highest point, the piston chamber pressure is lower than the suction cavity (low pressure), the suction valve open, compressed high-temperature high-pressure gas through the exhaust pipe into the condenser, and radiator pipe outside surface contact cooling to room temperature, condensation heat away, passed by in the radiator pipe of the cooling water to the cooling tower in diffusion into the atmosphere. By condensation point out is the high pressure refrigerant liquid at room temperature, after about into the thermal expansion valve, absorb a lot of heat, the temperature of the evaporator through the cooling load of the internal water reduced so proud, after evaporation heat of refrigerant vapor to machine that such as compressor and then compressed. Such a continuous loop, it can be transported to the outside world constantly cooling water.
Q:Why didn't air conditioning dehumidification function?
1, moisture is in the air moisture content with larger scale. 2, said bluntly, is sauna day under the condition of use. 3, such as rain, sunshine, even if the temperature is not high, but the humidity is very big, people feel the wet sweat out, you need to use air conditioning dehumidification mode.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range