Horizontal Single Phase SVC AC Voltage Regulator 5KVA
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 Piece pc
- Supply Capability:
- 2000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Power | 0.5kVA-10kVA(Horizontal) | 5kVA-60kVA(Vertical) |
Single phase input voltage | 70V-130V and 160V-250V | 160V-250V |
Single phase output voltage | 220V and 110V | 220V |
Accuracy of voltage stabilization | 220V±3% 110±6% | |
50Hz/60Hz | ||
1s(When input voltage has a charge of 10%) | ||
No additional waveform distortion | ||
>90% | ||
0.8 | ||
Tenperature:-5--+40 Humidity:<90% | ||
1500V/1min | ||
≥2MΩ | ||
1.5kVA-60kVA | ||
Phase voltage 160V-250V;Wire viltage 277V-430V | ||
Phase voltage 220V;Wire viltage 380V | ||
2-5% | ||
50Hz/60Hz | ||
1s(When input voltage has a charge of 10%) | ||
No additional waveform distortion | ||
>90% | ||
0.8 | ||
Tenperature:-5--+40 Humidity:<90% | ||
1500V/1min | ||
≥2MΩ |
- Q:Who knows how big transformers and lines the 36V transformer uses in lighting?
- Depending on your load capacity, primary voltage, site reservation, etc.. For example, 3.6KW lighting, with 4KVA transformers, the primary side 380V with 2.5 square (copper wire) enough, two times the side of 25 square.
- Q:How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
- The number of tables in this table is increasing when the table rings to show 1.Method 2 is only to measure the capacitance is good or bad, can not be measured capacity.
- Q:Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
- Because of the brightness of the 36V safety voltage lamp brightness in the overhaul work is not enough, so now the well lighting design should not be 36V, and replaced by 220V, and only need to add a leakage protector on it.
- Q:Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
- So, safety regulations: lighting transformer must double winding type safety isolating transformer, prohibited the use of autotransformer.
- Q:Is the substation separate from the power and illumination transformer?
- The power and illumination of the substation are all used on a transformer, which is separated by power and lighting by the station screen of this transformer.
- Q:What transformer can be used in a safety voltage lighting transformer?
- 220V/36V or 24V isolation transformer. Double winding, high and low voltage coils, not connected.
- Q:Power and lighting transformers, lighting quality will be affected much?
- Corresponding to the transformer power supply, in order to save costs and reduce costs, the choice of AC ignition method is better. Pure resistive load, the power factor is 1. The 3 *100W=300W is the capacity of the required transformer
- Q:How to calculate the rated capacity of small transformers for lighting purposes?
- But in fact, consider the total load, the importance, the location of the machine, and the future additional plan, according to the following order.
- Q:Does the lighting work properly? Doesn't that power equipment start voltage unstable?
- It is not easy to control, the power and lighting and electricity; if the transformer capacity is small, and relatively large power equipment start frequently, voltage stability will be poor, the lamp brightness will fluctuate dramatically, have effect on visual acuity. But as long as the design is reasonable, it has little effect.
- Q:How many can you bring with 220V? How many can you bring with 380V? There are 3 terminals on the transformer. There are 220V, 380V, 0, three terminals. 220V is the 220V terminal and the 0 connection. How can the 380V be connected? Is it 380V and 0 or 380V and 220V?
- Voltage x current = power, in general we are using the total power of 2/3, you can press this type of calculation, if the installation of electrodeless lights, the line should be separated,
1. Manufacturer Overview |
|
---|---|
Location | Shanghai, China |
Year Established | 2008 |
Annual Output Value | US$50 Million - US$100 Million |
Main Markets | South America Eastern Europe Southeast Asia Africa Oceania Mid East Eastern Asia Western Europe Central America Northern Europe Southern Europe South Asia Domestic Market |
Company Certifications | CE |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | Shanghai Port,Ningbo Port,Guangzhou Port |
Export Percentage | 81% - 90% |
No.of Employees in Trade Department | 6-10 People |
Language Spoken: | English, Chinese, Spanish, Arabic, French, Russian |
b)Factory Information | |
Factory Size: | 3,000-5,000 square meters |
No. of Production Lines | 10 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range | Average |
Send your message to us
Horizontal Single Phase SVC AC Voltage Regulator 5KVA
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 Piece pc
- Supply Capability:
- 2000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches