various types of pvc insulation power cable
- Loading Port:
- China main port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 200 m
- Supply Capability:
- 20000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1.Voltage: 1kv to 35kv
2. ISO, CCC Certificate
3. 22 years producing experience
4.Professional service
We can customize various types of cable in accordance with your requirements
XLPE /PVC insulated power cable
Mode and name
Power cable
Model | Name |
YJV YJLV | CU or AL conductor ,XLPE/pvc insulated PVC sheathed electric cable |
YJV22 YJLV32 | Cu or Al conductor XLPE /pvc insulated steel tape armoured ,steel wire armor pvc sheathed electric cable |
We can produce 1kv up to 35kv power cable
XLPE insulated power cable 0.6/1kv | |||||||||||
norminalsectional area | insulati-on thicknes | sheath thickness(mm) | overal diameter of cable (mm) | D.C resistance of conductor(km) | current rating | ||||||
in air(A) | direct in soil(A) | ||||||||||
cu | Al | cu | Al | cu | Al | ||||||
1×1.5 | 0.7 | 1.5 | 6 | <=12.1< span=""> | <=12.1< span=""> | 30 | 25 | 45 | 35 | ||
1×4 | 0.7 | 1.5 | 7 | <=7.41< span=""> | <=7.41< span=""> | 45 | 35 | 60 | 50 | ||
1×6 | 0.7 | 1.5 | 7 | <=3.08< span=""> | <=4.61< span=""> | 55 | 45 | 70 | 55 | ||
1×35 | 0.9 | 1.5 | 12 | <=0.524< span=""> | <=0.868< span=""> | 175 | 140 | 190 | 150 | ||
1×50 | 1 | 1.5 | 13 | <=0.387< span=""> | <=0.641< span=""> | 210 | 170 | 225 | 180 | ||
1×70 | 1.1 | 1.5 | 14 | <=0.268< span=""> | <=0.443< span=""> | 270 | 215 | 280 | 225 | ||
1×95 | 1.1 | 1.5 | 16 | <=0.193< span=""> | <=0.320< span=""> | 340 | 275 | 335 | 270 | ||
1×120 | 1.2 | 1.5 | 18 | <=0.153< span=""> | <=0.253< span=""> | 400 | 320 | 380 | 305 | ||
1×150 | 1.4 | 2 | 21 | <=0.124< span=""> | <=0.206< span=""> | 460 | 370 | 425 | 340 | ||
1×185 | 1.6 | 2 | 23 | <=0.0991< span=""> | <=0.164< span=""> | 530 | 415 | 480 | 375 | ||
1×240 | 1.7 | 2 | 25 | <=0.0754< span=""> | <=0.125< span=""> | 625 | 490 | 555 | 435 | ||
… | |||||||||||
3×1.5 | 0.7 | 1.5 | 10 | <=12.1< span=""> | <=12.1< span=""> | 25 | 25 | 30 | 30 | ||
3×2.5 | 0.7 | 1.5 | 11 | <=7.41< span=""> | <=12.1< span=""> | 30 | 25 | 35 | 30 | ||
3×4 | 0.7 | 1.5 | 12 | <=4.61< span=""> | <=7.41< span=""> | 40 | 30 | 50 | 40 | ||
… | |||||||||||
Attention: We can provide more info than above data, if needed.The above are just some examples. |
The desprition of 1kv copper xlpe insulated power cable
Characteristics of Cable
1.Max Long-time operating temperature of PVC insulated cable is 70°C,XLPE 90°C
2.Installing temperature of cable should not be less than 0°C
3.Max short-circuit temperature is:PVC not exceed 160°C,XLPE 250°C,Not more than5 Sec.
4.Permitting bending radius cable: Not less than 10 D times (D:external diameter of cable)
5.Perfect chemical stability, resistant against acids, alkali, grease and organic solvents, and flamer retardant.
Type and Specifiction
PVC Insulation Electric Cable
TYPE | Description of Cable
| Main Applications
| |
CU core | AL core | ||
VV | VLV | Copper/Aluminium core,PVC insulated,PVC sheathed power cable | Non-armoured PVC cable are suited for laying indoors,In cable trench,On cable racks and in pipes. Unable bear external pressures and tensions. |
VY | VLY | Copper/Aluminium core,PVC insulated,PE sheathed power cable | |
VV22 | VLV22 | Copper/Aluminium core,PVC insulated,steel tape armored,PVC sheathed power cable | Steel-tape armoured PVC cables are suited for vertical burial.Can bear moderate positive pressures,Unable bear tension forces. |
VV23 | VLV23 | Copper/Aluminium core,PVC insulated,steel tape armored,PE sheathed power cable | |
VV32 | VLV32 | Copper/Aluminium core,PVC insulated,thin steel wire armored,PVC sheathed power cable | Thin steel wire armoured PVC cables are used in case of great difference of levels or vertical installation and Can do vertical burial.Can bear moderate positive pressures and tension forces. |
VV33 | VLV33 | Copper/Aluminium core,PVC insulated,thin steel wire armored,PE sheathed power cable | |
VV42 | VLV42 | Copper/Aluminium core,PVC insulated,thick steel wire armored,PVC sheathed power cable | Thick steel wire armoured PVC cables are suited for vertical installation and can be laid water or sea-bottom.Can bear greater positive pressures and tension forces. |
VV43 | VLV43 | Copper/Aluminium core,PVC insulated,thick steel wire armored,PE sheathed power cable |
XLPE Insulated electric cable
Type | Description | Application | |
Cu Core | Al Core | ||
YJV ZR-YJV | YJLV ZR-YJLV | Cu(Al)Core, XLPE Insulated, PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, PVC Sheathed flame- retardant Power Cable | Can be laid in indoor, outdoor, tunnels, cable channels, reinforced concrete pipelines and loose soil. Cable should not bear outer mechanic force, but can bear a certain tractional force. |
YJV22 ZR-YJV22 | YJLV22 ZR-YJLV22 | Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed flame- retardant Power Cable | Laid underground. Cable can bear outer mechanic force, but should not bear large tractional force. |
YJV32 ZR-YJV32 | YJLV32 ZR-YJLV32 | Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed flame- retardant Power Cable | Laid in indoor, tunnels and mines. Cable can bear outer mechanic force and fairly large tractional force. |
YJV42 ZR-YJV42 | YJLV42 ZR-YJLV42 | Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed flame- retardant Power Cable | Can be laid in vertical section, indoor, tunnels and mines. Cable can bear outer mechanic force and very large tractional force. |
- Q:What is the difference between a YJV cable and a VV cable?
- How can you pick up the computer, Internet cafes router connected to the tap, each tap has a lot of jacks, so you can pick up so many computers, you can carefully observe the Internet cafes, some iron box there are a lot of green In the flash is the tap
- Q:I have a very old computer tower without the fat monitor. (which i through away years ago) I have some pictures on it that i would like to extract, but i don't know how to. And i lost the power cable to the tower. I would appreciate if you could help me. Thanks
- If you don't mind a bit of dust you an open the case and extract the Hard drive (It is hard to get the case off some old computers) Once its out, you can take it to a computer repair/shop and get them to get the stuff off of it.
- Q:I mean like the power connector cables. All power supplys have the same cables to supply power from the PSU to components right?
- not all PSUs have the same cables but they do all come with the same standard connectors. for example all PSUs regardless of wattage and brand will have the 4 pin molex conectors but not all will have the 6 pin and the 8 pin PCIe connectors and the higher end models will also come with 2 CPU 4 pin power connectors. which PSU you get depends on wattage demand of your system, amperage demand if you have a video card requireing extra power and the number of molex/sata power cables and PCIe 6/8 pin connectors you need.
- Q:I need 600W of power for my new computer, but all I have is 2 300W, 20-pin power supplies. What I'm wondering is if I can combine the 2 20-pin connectors and turn them into 1 24-pin connector?
- comput... repair las vegas
- Q:The power supply I have has 8 Peripheral cables. I need just a few more than that. Is there a cable splitter I can get? Or what can I do? I have the power, just need the extra connectors.
- capability furnish cables - no situation. USB cable, ensure you employ the comparable style of cable. HDD cable, you need to purchase longer ones, it rather is a extra efficient option than attempting to enhance the single you have. There are some sign themes in case you attempt to enhance the cable.
- Q:Hi,I have just bought a jasper xbox and i know this as it says ''12V, 12,1A'' on the back yet my power cable says ''12V, 16,5A''.I thought that the jasper xbox requires a specific power connector which wont fit the other types. Mine seems to fit fine, so have i got something wrong here? Cheers
- i don't know if somethings wrong with your xbox or power brick but i can tell u tho, if u use a Xenon power brick (12V,16,5A) on a jasper xbox u will run into a problem later on, for it will overheat and the CPU and GPU will warp and pull there self away from the motherboard, if u have ever heard of the towel trick( wrapping your xbox in a towel so it will overheat and the solder will pool up and re-solder the CPU/GPU back in place) that's where it come from, i would buy a jasper power brick if i were u (12V, 12,1A).
- Q:I disconect them and now, i don't know how to put them back like they supposed to. Can someone please tell me how to do this? please!!This is some of the information that i got from my PC.OS NameMicrosoft Windows XP ProfessionalVersion5.1.2600 Service Pack 2 Build 2600OS ManufacturerMicrosoft CorporationSystem NameMY-DBVYSKQ1KC1OSystem ManufacturerVIA Technologies, Inc.System ModelKM266-8235System TypeX86-based PCProcessorx86 Family 6 Model 6 Stepping 2 AuthenticAMD ~1396 MhzBIOS Version/DatePhoenix Technologies, LTD 6.00 PG, 11/7/2002SMBIOS Version2.2Windows DirectoryC:#92;WINDOWSSystem DirectoryC:#92;WINDOWS#92;system32Boot Device#92;Device#92;HarddiskVolume1LocaleUnited StatesHardware Abstraction LayerVersion = quot;5.1.2600.2180 (xpsp_sp2_rtm.040803-2158)quot;User NameMY-DBVYSKQ1KC1O#92;myTime ZoneEastern Standard TimeTotal Physical Memory512.00 MBAvailable Physical Memory79.05 MBTotal Virtual Memory2.00 GBAvailable Virtual Memory1.96 GBPage File Space817.16 MBPage FileC:#92;pagefile.sys
- If your talking about the power cables from the power supply to the motherboard those are fairly straight forward. It is a 20 or, 24 pin connector. Usually along the edge opposite the external connections for the motherboard. Although, the placement really depends on the manufacturer and, could even be near the middle of the board. They are keyed and, you can not plug them in incorrectly. As long as you don't force them into the slot. If your speaking of the wires from the case to the motherboard that is a little more difficult. P3 and, P4 motherboards usually have a keyed connection that simply plugs in. Other boards have markings on each of the wires corresponding with it's connection. The one thing that is the same for every board is that the two black wires must be side by side. If you've never done it before you should have labeled each wire and, made a diagram of their placement. Your best hope short of taking your computer to the local shop is to try and, find diagrams for both your motherboard and, the case.
- Q:How do I connect this unit to my cd player? Splicing power cables? not too detailed in the manual.?
- im sure it comes with a power harness(plug) you prob have to do some splicing just connect it t0 the same place where you get power for the cd player your probably going to get a wire harness for your cd player right? just match the wires from your cd to your ipod thingy before you solder or crimp your connections
- Q:I'm installing aftermarket amp and subwoofers in the trunk. I currently as a temporary fix ran the cable outside and in through the passenger door on the car, then under the carpet to the trunk. Is there a break in the firewall anywhere that I can put it through instead? Thanks for your help!
- examine first if there are the different wires that have been given burned apart from the distant twine and the flexibility cable. examine additionally your fuse if that's nevertheless ok. confident, you ought to purchase those wires from a ironmongery shop or an digital keep via ft or via backyard.. For the flexibility cable use gauge 8 or gauge 4 wires, for the distant twine use gauge sixteen or 14. until now setting up the wires be sure to ascertain your amp and your stereo if there are nevertheless working because of the fact short circuit on power cable often ends up in broken the audio factors interior the amp or the vehicle stereo or the two. be sure to double examine all connections and conenct the fuse of the flexibility cable final to circumvent short circuiting
- Q:How to distinguish between power cables and electrical wiring on drawings
- Cable ends should be marked with cable head symbols, the middle line should also be different from the ordinary wiring. Bv at the beginning of the general wire, with YJV or vv is generally a cable, but not limited to these
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
various types of pvc insulation power cable
- Loading Port:
- China main port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 200 m
- Supply Capability:
- 20000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches
Related keywords