• V(WQ) Submersible Sewage Centrifugal Pumps System 1
  • V(WQ) Submersible Sewage Centrifugal Pumps System 2
V(WQ) Submersible Sewage Centrifugal Pumps

V(WQ) Submersible Sewage Centrifugal Pumps

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
2000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1) Function and Feature:
This adcanced V(WQ)series,a branch of single-phase drainge pumps, will be your ideal drainage helper. The letter’V’which substitutes for the letters "WQ"indicates the distinct design of the filter and the broadness of the high efficient area. It can work safely and efficiently at high flux with the feature of Complete heads. The design is designed to a wide tunnel which helps to convey the long fiber liquid of the solid whose diameter Is about 15-35mm. The selection of bottom suction strcture, stainless steel and special and castiron make the pump has the capabilities of complete drain and high resistance of abrasion and corrosion. The float switch can automatically control on and off with the change of the liquor lever. The protector in the motor can automatically cut off the power when it overheated or overcurrented. Thus guarantee the security and

2) Work Conditions:
1.The maximum deep it is allowed in water is 5m from its center of impeller;
2.The trans mediums temperature shouldn t higher than 40℃
3.The trans medium’s FH scope is from 4~10
4-Thc kinematics viscosity of the trans medium is from7x10~7x10~5.The maximum density of the tr^ns medium is 1.2x10³kg/m³


Model

Flow
(m³/h)

Head
(m)

Voltage
(v)

Pipe size

(mm)

V180

5

7

220

40 32 35

V250

5

7.5

220

40 32 35

V370

5

7.5

220

40 32 35

V450

6

8.5

220/380

50

V550

7

8.5

220/380

50

V750

10

12

220/380

50

7

12

220/380

50

V1100

10

14

220/380

50

16

9

220/380

50

V1300D

18

12

220/380

50

V1500

6

23

220/380

40

V2200

30

17

220/380

80


3) FAQ

1.  Can I get trained on CNBM products?

Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.

2.  Are your pumps cheaper than those of your competitors?

CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.

3.  How long is your warranty?

Unless otherwise expressly authorized in writing, by specifying a longer period or different conditions, CNBM states that, for a period of twelve (12) months from delivery date, all Products supplied are free from defects in materials and workmanship, and conform to the applicable specifications. Either the delivery documentation or the invoice must be provided to prove delivery date. In absence of such documents, the production date appearing on the product label may suffice.

V(WQ) Submersible Sewage Centrifugal Pumps

V(WQ) Submersible Sewage Centrifugal Pumps


Q:Double floor sewage pump circuit diagram of a small problem
Question 4 when you need backup, you need to switch the SA switch, but where you want it. For example, when the 1# pump is running and does not reach the high water level, the 2# pump will not operate. If SA is placed in the left position, 21 and 22 are connected, and the KT is electrically delayed, and the KAB action causes the 2# pump to function. After the KAB operation, the KT will be disconnected, restored to the ready state, and also convenient for KT to restart the power on time, and also avoid the time relay to work on a long-term basis.
Q:Piston filling and peristaltic pump filling which precision is high?
These two pumps are used as a metering pump to use, so the accuracy is to be on a par with the peristaltic pump has more advantages than the piston pump is the largest energy fluid conveying there are particles, and the piston pump is smaller than the peristaltic pump pulse, so we need to choose according to the material characteristics you need to transport.
Q:What is the working pressure of the hydraulic pump in the hydraulic transmission system?
The choice of pressure depends on the size of the load and the type of equipment. Consideration shall also be given to the assembly space, the economic conditions and the availability of components for the actuators.In the case of a certain load, low working pressure, is bound to increase the structure size of the actuator on some devices, the size must be limited, from the perspective of material consumption is not the economy; on the other hand, the pressure to choose too large, the pump, cylinder, valve and other components of the material, sealing and manufacturing accuracy requirements very high, must raise the cost of equipment.
Q:Concrete pump 125 pipe wall thickness
Currently mainly divided into gate valve, concrete pump and S valve concrete pump. Another is a pump consisting of a pump body mounted on an automobile chassis and fitted with retractable or bent cloth poles
Q:Why is the flow of the pump too small will occur cavitation phenomenon?
Throttling regulation is to change the opening of the valve to change the flow of the pump, that is to say, to change the characteristic curve of the pipeline. The commonly used to regulate the flow of exports, because the entrance throttle makes reduce the inlet pressure caused by cavitation danger.
Q:Why does the centrifugal pump start and close first when the outlet valve is closed?
When the valve is closed off opposite is the first current to the rated current, avoid instant electricity loss of other electrical equipment caused by voltage fluctuation. At the same time, some centrifugal pump outlet check valve is not installed, the role of avoiding the pipeline caused by backflow of water pump reversal.This Regulation (or operation regulation) is generally applicable to larger power centrifugal pumps. For small power equipment, it can be used to determine whether the above operation is necessary for actual use
Q:How does the centrifugal pump pump and cut the pump?
Can not be generalized, the pump is divided into many categories, centrifugal, reciprocating, screw type, diaphragm type, and so on, the starting steps of each pump is not the same. The following is the centrifugal pump and reciprocating pump to do a simple introduction. Check the items and so on.Centrifugal pump: first open the pump inlet valve, pump exhaust, and then start the motor, slowly open the outlet valve. If it is a high speed motor or multi-stage pump, open the motor before the outlet valve slightly open.Reciprocating pump: slightly open the inlet valve of the pump, fully open the outlet valve. After starting the motor, at the fully open inlet valve.Here is a brief introduction. I hope it works for you.
Q:What are the causes of pump shock?
3. the water pump set screws loose, adjust the concentric, fastening the foot4. pump into foreign body, open cover overhaul5. the flow is too large or too small, adjust the equipment to control the water output
Q:What is the difference between swashplate pump and crankshaft pump?
Swash plate pump motor is driven as a coaxial swash plate drive plunger pump crankshaft work produces high pressure water in general simply and motor rotor to form a 90 degree angle of the motor through the crankcase to drive the piston to work in general the crankshaft speed is relatively high in the 2800 turn left and right to use the cost of the swash plate speed the use of less than 300 kg pressure in about 1400 when the crankshaft is relatively high but in more than more than 300 kilograms of crankshaft pump highlights the advantage of his adopted lookout!!!
Q:What is a positive displacement pump? He Weizheng displacement?
And includes a pump chamber (24) to open and a channel is arranged between the entrance and the pump chamber (26) in the second one-way valve (15), and one for the continuous displacement member (13) in the pump shell (10) in the travel section (S) actuating mechanism reciprocating motion.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products