Switch Power Supply 24V 600 Watt
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 10 Pieces pc
- Supply Capability:
- 10,000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specification:
Model | HS-600-12 | HS-600-13.5 | HS-600-15 | HS-600-24 | HS-600-27 | HS-600-48 |
Specification |
|
|
|
|
|
|
DC output voltage | 12V | 13.5V | 15V | 24V | 27V | 48V |
Output voltage tolerance(Note:2) | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% |
Rated output current | 50A | 44.5A | 40A | 25A | 22A | 12.5A |
Output current rage | 0-50A | 0-44.5A | 0-40A | 0-25A | 0-22A | 0-12.5A |
Wave and noise(Note :3) | 240mVp-p | 240mVp-p | 240mVp-p | 240mVp-p | 240mVp-p | 300mVp-p |
Inlet stability(Note :4) | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load stablity (Note :5) | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Efficiency | 80% | 80% | 82% | 82% | 82% | 84% |
AC input voltage range | 180-264VAC 47-63Hz;254-370VDC | |||||
6.5A/230V | ||||||
50A/230V | ||||||
<3.5mA/240VAC | ||||||
105%~135% hiccup mode, auto recovery | ||||||
115%-135% cut off the output, auto recovery | ||||||
ERH3>=65°C~70°C Fan on,<=55°c~60°cfan>=80°C~85°C,Cut off output(5~15V)Cut off output(5~15)~(24~48V) | ||||||
±0.03%/°C(0~50%) | ||||||
200ms,100ms,20ms | ||||||
10~500Hz,2G 10min,/1cycle,Period for 60min,each axes | ||||||
Input and output internal:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC | ||||||
Input and output internal:Input and enclosure,Output and enclosure:500VDC/100MΩ | ||||||
-10°C~+60°C(Refer to output derating curve),20%~90%RH | ||||||
-20°C~+85°C,10%~95%RH | ||||||
238×124×65mm | ||||||
1.5Kgs, 12pc/CTN | ||||||
- Q:Power and lighting transformers, lighting quality will be affected much?
- The quality of transformer itself, coupling coefficient, overload capacity, as well as the impact current of the bulb, the cold resistance of the filament and the starting factor at the same time, it is better to choose the 400VA transformer.
- Q:Why can't autotransformer be used as transformer for safety lighting?
- The transformer of the lighting circuit is a step-down transformer (general input 10kv., 220V). The first coil of the autotransformer is shared and connected together
- Q:Which is more energy saving by using 24V500W transformer lighting and 220V500W lighting?
- If the transformer is not calculated, the loss is the same. If the calculation is the latter, save electricity.
- Q:Is the substation separate from the power and illumination transformer?
- The power and illumination of the substation are all used on a transformer, which is separated by power and lighting by the station screen of this transformer.
- Q:What type of low voltage transformer should be adopted for safety lighting power supply?
- Isolated transformer, once 380V or 220V, two voltage, 36V, 24V, 12V, several categories, do not allow the use of autotransformer.
- Q:3 24V100W lights, I need to use a large capacity transformer (220V change 24V)?
- The quality of transformer itself, coupling coefficient, overload capacity, as well as the impact current of the bulb, filament, cold resistance and simultaneous startup factor, it is better to choose the 400VA transformer
- Q:How to calculate the rated capacity of small transformers for lighting purposes?
- But in fact, consider the total load, the importance, the location of the machine, and the future additional plan, according to the following order.
- Q:Does the lighting work properly? Doesn't that power equipment start voltage unstable?
- Connection mode:N circuit breaker is caused by breaker of outlet line of transformer main cabinet.The branch circuit breaker divides the power, the electricity and the lighting power.
- Q:What transformer can be used in a safety voltage lighting transformer?
- An isolated transformer is a transformer that is electrically isolated from an input winding and an output winding. The isolated transformer is used to avoid accidental touching of the charged body at the same time, and the isolation of the transformer is to isolate the current of the former side winding coil.
- Q:Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
- The self winding transformer is connected by all its windings, and depends on the position of the sliding contacts to change the magnitude of the voltage. Therefore, there is not only a magnetic connection between the primary winding of the autotransformer (the power circuit) and the two winding (the power supply circuit), but also the direct connection of the circuit. It forms a circuit with the earth, so it can not be used as the power source of the safety voltage
1. Manufacturer Overview |
|
---|---|
Location | Shenzhen, Guangdong, China (Mainland) |
Year Established | 2011 |
Annual Output Value | US$5 Million - US$10 Million |
Main Markets | North America; South America; Eastern Europe; Southeast Asia; Mid East; Western Europe; Central America; Northern Europe; South Asia |
Company Certifications | ROHS Test Report; Waterproof Power Supply CE-LVD; Waterproof Power Supply CE-EMC; CE-LVD |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | Yantian |
Export Percentage | 41% - 50% |
No.of Employees in Trade Department | 3-5 People |
Language Spoken: | English, Chinese, Spanish, Japanese, Portuguese, German, French, Russian, Korean, Italian |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Switch Power Supply 24V 600 Watt
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 10 Pieces pc
- Supply Capability:
- 10,000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches
Related keywords