Single Core Wire 0.75mm Electrical Cable Green/Yellow

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
10000 m
Supply Capability:
1000000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specifications of  Single Core Wire 0.75mm Electrical Cable Green/Yellow 

PVC sheath solid conductor electrical wire 
ISO 9001-2008 
Voltage: 450/750V 
Cross section:1.0mm2 to 500mm2 
OEM acceptance

Solid copper conductor Single Core Wire 0.75mm Electrical Cable Green/Yellow 

 

1.electrical wire is usually PVC insulated wire

PVC insulation no-sheathed general purpose electrical wire,single core,solid

2.sheathed round wires:

copper(aluminum)conductor pvc insulated pvc sheathed solid wires

copper(aluminum)conductor pvc insulated pvc sheathed flexible wires

Sizes:0.5-185mm2

3.products can be produced and provided accroding to standard G/T5023,IEC60227,BS6004,JB8734.

Standard:

GB/T5023.1-1997  450/750V or below PVC insulated electric wires.

GB/T5023.1-1997 is identical to IEC227,models are the same,can be produced according to customers requirement.

Using purpose:

4. used for AC rated voltage 450/750V and below for the followings:

lighting,electrical installation,the connection between instrumention and telecomunication equipment

 

Technical Data Sheet of  Single Core Wire 0.75mm Electrical Cable Green/Yellow

Class 2 Conductor

Nominal
sectional area
mm2

Conductor
No/Dia.
mm

Nominal
Insulated thick
mm

Max overall
Dia.
mm

Condcutor
Resistance at
20

Weight
Kg/km

Cu

Al

Cu

Al

1.5

1/1.38

0.7

3.3

12.1

-

19.2

-

2.5

1/1.78

0.8

3.9

7.41

11.8

30.8

15.0

4

1/2.25

0.8

4.4

4.61

7.39

45.5

21.0

6

1/2.76

0.8

4.9

3.08

4.91

65.0

29.0

10

7/1.35

1.0

7.0

1.83

3.08

110.0

52.0

16

7/1.70

1.0

8.0

1.15

1.91

170.0

70.0

25

7/2.14

1.2

10.0

0.727

1.20

270.0

110.0

35

7/2.52

1.2

11.5

0.524

0.868

364.0

150.0

50

19/1.78

1.4

13.0

0.387

0.641

500.0

200.0

70

19/2.14

1.4

15.0

0.268

0.443

688.0

269.0

95

19/2.52

1.6

17.5

0.193

0.320

953.0

360.0

120

37/2.03

1.6

19.0

0.153

0.253

1168.0

449.0

150

37/2.25

1.8

21.0

0.124

0.206

1466.0

551.0

185

37/2.52

2.0

32.5

0.099

0.164

1808.0

668.0

 

 Class 5 Conductor of  Single Core Wire 0.75mm Electrical Cable Green/Yellow

Nominal
sectional area
mm2

Conductor
No/Dia.
mm

Nominal
Insulated thick
mm

Max overall
Dia.
mm

Condcutor
Resistance at
20

Min insulated
resistance at
70MΩ/km

Weight
Kg/km

2.5

9/0.41

0.8

4.2

7.41

0.011

33.0

4

19/0.52

0.8

4.8

4.61

0.009

48.0

6

19/0.64

0.8

5.6

3.08

0.0084

68.0

10

49/0.52

1.0

7.6

1.83

0.0072

115.0

16

49/0.64

1.0

8.8

1.15

0.0062

176.0

25

98/0.58

1.2

11.0

0.727

0.0058

272.0

35

133/0.58

1.2

12.5

0.524

0.0052

384.0

50

133/0.68

1.4

16.5

0.387

0.0051

510.0

70

189/0.68

1.4

16.5

0.268

0.0045

714.0

95

259/0.68

1.

19.5

0.139

0.0035

965.0

120

259/0.76

1.8

22.0

0.153

0.0032

1210.0

150

259/0.85

1.8

25.0

0.124

0.0032

1510.0

 

Pictures of  Single Core Wire 0.75mm Electrical Cable Green/Yellow

Single Core Wire 0.75mm Electrical Cable Green/Yellow



Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Is the toilet wire walk on the ground? Are there any hidden dangers?
At the same time, security monitoring line itself is a weak line
Q:Where should the inner diameter of the plastic tube of the cable be at least the number of times the outer diameter of the cable?
Data line pregnant, I also appeared once for a data line on it.
Q:2.5 square copper (green, with the threading tube) can withstand the highest power of several kilowatts,
Should be the line group: lighting a group of 2.5 square millimeters, an ordinary socket a group of 4 square millimeters, air conditioning a group of 6 square millimeters, kitchen and bathroom appliances a group of 4 square millimeters, so that after the down is not enough to put a separate group You say the high-power electrical outlet, the line to the square of the square mm to see your home how high-power electrical appliances, but advise you to use these high-power electrical appliances before the first to determine its current good, More than your home appliance load!
Q:Home leaked, installed in the floor below the wire was blisters will have any security risks? How can the water inside the pipe to dry
Cable is a unified call, including power cables, communication cables, etc., I do not know what type of cable you need the type specifications. On the power cable in terms of the main models are: VV, BJV, VV. BJV. . ZR, NH and other models, as the specifications that too much.
Q:Help look at such a configuration will not have compatibility issues! Do you need to improve? Budget in 5500 or so
Power lines tied together, usb line bundled together, high and low pressure apart. Tie the tie on the line
Q:Fiber optic cable split box, integrated wiring box, cable terminal box, cable transfer box difference
Outdoor fire line must use fire-resistant KVV cable, wear pipe protection.
Q:Wire and cable CCC product consistency is what
Wire of course, is to use a good slightly, the first life, ah, can not buy cheap because of cheap, like China's top ten brands to buy the brand on the purchase of these brands I feel very good ah, Po Sheng , Luneng Taishan, Far East, Shenghua cable, on the up, prosperous photoelectric, Nexans Nexans these brands of wire is still very good. The landlord you can go to the above to learn more detailed information ah, the top ten wire brand is very detailed, the landlord can understand very clearly, the above brand is very good, my father last time to go above to see, and then buy
Q:Will the extension of the output of the electric vehicle charger wire affect the voltage?
Please provide air-conditioned three-leg socket photo, because you said "open inside is 2.5 square line ~ is a separate line ~" is not very understanding.
Q:Seeking the basement of the outer wall piercing the cable after the casing, how to solve the water (200 points online)
Wire diameter, conductor resistance, insulation diameter, the thickness of the thinnest insulation,
Q:What is the difference between a kbg threading pipe and a PVC threading pipe?
You should be said: 2-way cross-linked polyethylene insulated PVC sheathed cable 4 core 185 square millimeters, SC is steel pipe, diameter . FC is laying method dark cover the floor or floor. Personal opinion, hope to help you!

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range