SC 100% Solar Power DC Inverter Modular Chiller Type Air Conditioner

Ref Price:
$812.67 - 1,023.00 / set
Loading Port:
SUNTCH
Payment Terms:
L/C,T/T
Min Order Qty:
1 Set set
Supply Capability:
3000 Sets per Month set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

 

 

Introduction

This modular air-cooled heat pump air conditioner does not use any combustion process or energy to generate heat.It only uses little electricity to transfer the enery from air to effect heating and cooling,which are suitable for villas,hotels,factories,schools,salons,leisure centers,etc.Modular design available for compose to bigger system to meet any size of big heating or cooling capacity requirments. 

Features

 

1.Working without water-cooling tower,it provides easier installation and higher mobility.Independent cooling system. It's a wonderful choice for places lacking of water or those water-cooling tower is not applicable.

2.Low noise fan motor provides excellent cooling and condensation effects.The throttle unit is stable,with high-grade anti-rust treatment.

3.Compressor---Equipped with a world famous brand Copeland scroll compressor.The compressor operates smoothly and quietly at high EER value.

4.Thermal expansion valve(TXV)---Normally, our standard type is Danfoss brand.

5.Condenser---SUNCHI air-cooled scroll chiller adopts fin type with copper coil.

6.Evaporator---Normally,there are 3 types for the evaporator,water tank copper coil,shell and tubes,stainless steel heat exchanger.

 

Parameters List

Modular Air Cooled Scroll Chiller (Cooling & Heating)
ModelLSQWH20/MD50CF/LSQWH20/MD50AFLSQWH30/MD50CF/LSQWH30/MD50AF
Product useCooling & Heating
Cooling capacitykW66100
Btu/h225256341297
Heating capacitykW72110
Btu/h245734375427
Heat exchangerHigh efficient fin coil type
Power supply380V/3PH~ 50Hz
Net weight(kg)840920
Product Dimension (mm)2120×1050×21502120×1050×2150
Package size (mm)2320×1150×2300970×470×1480
Noise dB(A)≤68≤72
Electric shock protection classI
Waterproof gradeIPX4
Rated input power(kW) -Cooling21.534.2
Rated input current(A)-Cooling36.357.7
Max input power(kW) -Cooling2844.5
Max input current(A) -Cooling47.375.1
COP data-Cooling3.072.92
Cooling output water temp.7°C
Rated input power(kW)-Heating2235
Rated input current(A)-Heating37.159.1
Max input power(kW)-Heating2945.5
Max input current(A)-Heating4976.8
COP data-Heating3.273.14
Heating output water temp.45°C
Compressor QTY /name brandR22/R410A2/Copeland3/Copeland
RefrigerantR222×10kg3×10kg
R410A2×8kg3×8kg
Circulating water flow11.417.2
Water pipe diameterDN50DN50
Working for ambient temperature-10°C~45°C
Test ConditionCooling:Ambient temp.(DB):35°C     Heating:Ambient temp.(DB/WB):7°C/6°C 

 

Packaging & Shipping

Package and Delivery

1.Standard Export Package (Exterior Plywood Case & Interior Plastic Films)
2.Bottom fixed with Screws to make sure delivery stablility.
3.Two Weeks after confirming payment.

 

Our Services

 

Quality Control

1.Complying with ISO standard. Quality Ensured.
2.Using world famous Compressor,i.e. COPLAND, PANASONIC, MITSUBISHI,HITACHI, SANYO
3.Complete Inspection covering water system and electricity, ensuring stable hot water production.
4.Equipped with high efficiency tube in shell heat exchanger, finned heat exchanger or plate heat exchanger. All heat exchangers with insulation to prevent heat loss.
5.Evaporator using surface modification of hydrophilic aluminous foil.
6.Electric Expansion valve with accurate flow control and gas distribution.
7.LCD display control panel. Intellectual control over water pump, water supplement, water discharge and defrosting system.

 

 

FAQ

Q1:Why is it important to use home air conditioner filters?

A:Without them you can clog up vital parts of the heating or cooling components that can be difficult to clean out and can cause severe damage that will be much more expensive to repair than the inconvenience of replacing a filter once a month.

Q2:What is VRF Air Conditioning System?

A:VRF air-conditioning systems owe their growing popularity to their ability to meet a wide range of requirements.

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What are the several types of general family expenses air conditioning?
1, air conditioning air conditioner (air conditioner), also known as the air conditioning. Refers to the use of artificial means, within the buildings/structures on the ambient air temperature, humidity, cleanliness, speed and other parameters to adjust and control the process. 2, generally including cold source and heat source equipment, hot and cold media distribution system, terminal device such as a few most and other auxiliary equipment. Mainly include water pump, fan and piping system. Terminal device is responsible for the use of distribution to the cold heat, specific processing air, air parameters of the target environment is achieved
Q:Heating principle of household air conditioning and refrigeration principle respectively is what?
Estimate what you said is household air conditioning. Refrigeration principle: compressor work makes evaporator () in the indoor machine is in low pressure condition, the rapid evaporation absorbs heat liquid refrigerant inside the evaporator, air blown air after cooling evaporator coil into a cold wind blow to indoor, after evaporation vaporization of the refrigerant by compressor pressure, under the environment of high pressure in the condenser (seg) condenses into liquid, releasing heat, through the fan, outdoor will heat to the atmosphere, so to reach the refrigeration effect. Heating principle: one kind is contrary to the cooling process, the imagine in the summer, the exchange and the house, the room is hot air blow out, of course, in the winter outdoor temperature is very low, this way of heating efficiency is very low. The second is heating, electric heating tube directly convert electrical energy into heat energy, high efficiency, is generally used in ark on the high power monomers such as air conditioning. There are many forms of central air conditioning heat and cold source, such as electric refrigeration (the principle is the same as household air conditioning refrigeration principle) + boiler, lithium bromide absorption direct-fired machine, ground temperature (hot) central air conditioning, ice storage cold storage central air conditioning and so on. Actually, removed by burning or electricity direct heating, refrigeration and heating principle of the other popular speak be heat transport
Q:What is the high pressure and low pressure air conditioning? How to measure?
High pressure compressor exhaust pressure Low pressure of the compressor suction pressure. Usually on the compressor suction and exhaust valve has a special interface, using fluoridated table joins can be measured If is home air conditioning is a little trouble, to see if there is any plunger valve, so, measurement is connected by fluorine list
Q:Room with a home air conditioning?
Can, only equipment precision control to the environment temperature and humidity, the request is not high
Q:Air conditioning can generally use a few years?
Winter best meets once every two months, electricity heating (compressor) twenty minutes before opening, according to the remote boot again! Once a half an hour! Air conditioning often period without compressor 'four-way valve will card cylinder, jam!
Q:Air conditioning machine which is high pressure pipe? Which is of low pressure pipe?
Dizzy. Touch two pipes, feel carefully, the pipe is low pressure, low temperature is the high temperature high pressure. The temperature of the high pressure of high temperature, low pressure low
Q:Air conditioning is vertical well, or hanging a good?
Vertical or hanging, as long as the work, are good! However, vertical occupies the ground area; Do not take up it hanging. Vertical, children may be surprisingly easy to contact, manufacturer can not guarantee compensation; The safety of hanging better! General hall is more than 20 square metre, exo are mostly of small power, hard to work efficiently, so a lot of people choose vertical. My family's choose hanging sanyo big 2 p, winter and summer respectively are very easily cope with more than 30 square meters of the dining room of the sitting room + refrigeration, warm! For reference only!
Q:Air conditioning energy consumption ratio is what mean
Is refers to the consumption of a certain power, produce the corresponding amount of cold or heat. Both the ratio of the higher the better, show higher energy conversion, energy saving.
Q:Useful three-phase electric air conditioning is what kind of?
Ha ha, is really too much, more than 3 p and 3 p is 380 v three-phase power!Have a group of 3 p and 5 p
Q:How to vacuum home air conditioning
Had better use vacuum pump, can also be used under the condition of no refrigerant. Is to add refrigerant gas to 3 kg pressure, then put away, and, again, again and again for three or four times, and then can add refrigerant liquid. But new had better use vacuum pump, installation company should have

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range