• Gel  Battery MPG Series Battery  MPG12V135F System 1
  • Gel  Battery MPG Series Battery  MPG12V135F System 2
  • Gel  Battery MPG Series Battery  MPG12V135F System 3
Gel  Battery MPG Series Battery  MPG12V135F

Gel Battery MPG Series Battery MPG12V135F

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1000 unit
Supply Capability:
500000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing


 
 Range summary:

The MPG range gel batteries are designed with front terminal structure. The perfect design ensures MPG series battery the high reliability and makes the installation quite simple and safe when placed on a standard relay rack tray or in a closed cabinet. Adopt Flat plates with gel electrolyte.

This new technology leverages on the advantages of the AGM and Ares technology to provide better cycle performance versus the AGM technology and a shorter time discharge performance as compared with the Gel technology.

MPG range gel battery is designed with high energy density and suitable for 19", 23" rack or cabinet, and also offers options of top connection and side of monoblocs connection. MPG range battery can be equipped with central gas collection system according to the requirement of customer.

The MPG batteries are ensured the quality with the ISO9001 standard.

Gel  Battery MPG Series Battery  MPG12V135F

Technical feature:

  • Gel technology applied in MPG range batteries.

  • Front-access terminal connections for fast and easy installation and maintenance

  • Suitable for 19", 23" rack or cabinet

  • Excellent special lead-tin-calcium formula alloy for Grids and plates

  • Mircoporous glass mats in low resistance as separator

  • Self-regulating pressure relief valve

  • 12+ years expectant Life under full float service at 25oC(77oF)

 

Type:

  MPG12V135F

Voltage:

  12V

Nominal Capacity:

  135Ah(C10)  135Ah(10 hours rate:)

Length:

  558mm

Width:

  125mm

Height:

  270mm

Height   with termial:

  270mm

Weight:

  48Kg

Compliant standards :

  • IEC60896-21/22

  • Din standard

  • UL

  • Manufactured under system ISO9001(TUV)

Battery installation compliant with:

  • EN 50272-2 or local equivalents

Main application:

  • Telecommunications

  • Uninterruptible power supply (UPS)

  • Switchgear / utility

  • Other applications to provide integrated stored energy system

Products characteristics:

  • Recommended float charge voltage for 12V  battery:

  • 2.25Vpc at 25oC(77oF)

  • Self discharge rate: < 2% per month at 25oC(77oF)

  • Shelf life: six months at 25oC(77oF)

  • Valve regulated system, no water addition  needed.

FAQ


What is sulfation of batteries?

Sulfation is the formation or deposit of lead sulfate on the surface and in the pores of the active material of the batteries' lead plates. If the sulfation becomes excessive and forms large crystals on the plates, the battery will not operate efficiently and may not work at all. Common causes of battery sulfation are standing a long time in a discharged condition, operating at excessive temperatures, and prolonged under or over charging.

How long a battery can last?

The service design life of a battery are vary considerably with how it is used, how it is maintained and charged, temperature, and other factors.

Do batteries self-discharge when not in use?

All batteries, regardless of their chemistry, self-discharge. The rate of self-discharge depends both on the type of battery and the storage temperature the batteries are exposed to. However, for a good estimate, Narada batteries self-discharge approximately 4% per week at 80ĄăF.

How can I evaluate the health and charge state of a battery?

Routine battery examinations divulge irregularities in the charging system as well as in the batteries. The principle method is to examine the electrochemistry of the battery through hydrometric electrolyte inspection. As previously discussed, this important examination cannot be accomplished with sealed absorption or gel batteries. Voltage readings alone require experience to interpret. Hydrometric readings will uncover early warnings of overcharging or overdischarging before batteries are damaged. The state-of-charge and reliability of a lead acid battery can best be determined by the specific gravity of the electrolyte measured directly with a common bulb-type hydrometer with a glass float. We do not recommend the ball float type hydrometer. Specific gravity is a unit of measurement for determining the sulfuric acid content of the electrolyte. The recommended fully charged specific gravity of marine batteries is 1.255 to 1.265 taken at 80ĄăC More than .025 spread in readings between fully charged cells indicates that the battery may need an equalization charge. If this condition persists, the cell is failing and the battery should be replaced. Since water has a value of 1.000, electrolyte with a specific gravity of 1.260 means it is 1.260 times heavier than pure water while pure concentrated sulfuric acid has a specific gravity of 1.835.


 

Q:What is a maintenanceable battery?
Maintenance-free battery due to its own structure on the advantages of electrolyte consumption is very small, in the life of the basic need not add distilled water.
Q:What is the difference between a maintenance-free battery and a conventional battery?
Different materials will produce a different phenomenon: the traditional battery in the course of the use of the phenomenon of liquid reduction occurs, because the antimony on the grid will pollute the sponge on the negative plate of pure lead, weakened after the full charge of the battery Electromotive force, resulting in excessive decomposition of water, a large number of oxygen and hydrogen, respectively, from the positive and negative plates to escape, so that the electrolyte reduced. With calcium instead of antimony, you can change the fully charged battery back electromotive force, reduce the overcharge current, liquid gasification rate decreases, thereby reducing the loss of electrolyte.
Q:What is the meaning of the battery above 12v65Ah?
12V is said to be the voltage, 65Ah is the current. (A is the unit of current. H is the time unit .1 hours.)
Q:How to repair the battery?
To the battery in accordance with the 0.1C current discharge, record the discharge time. Its discharge current multiplied by the number of hours of time, is the battery repair capacity. If the Chongqing battery capacity to reach the nominal capacity of more than 70%, the end of the repair.
Q:How to deal with waste batteries?
Laboratory recycling method: ordinary dry battery is cylindrical, the outer cylinder made of zinc, the zinc cylinder is the battery negative; tube central carbon rod for the positive; tube for the manganese dioxide, ammonium chloride and chlorination Zinc.
Q:What are the hazards of battery over discharge?
Excessive discharge can seriously damage the battery's electrical performance and cycle life.
Q:What kind of battery is divided into?
At present, we used the car battery is divided into three categories, namely, ordinary batteries, dry batteries and maintenance-free batteries three.
Q:Lead-acid battery how to maintain?
After 5 hours of repair, the excess electrolyte is sucked out with a straw, and if the electrolyte is sucked out into black, it indicates that the battery is severely grounded and that the battery is difficult to repair.
Q:Maintenance-free battery how to detect it?
Battery pole Pole terminal has corrosive material without treatment, as long as no loose on it. If the appearance of the corrosive material, the inner surface of the terminal will also be corrosion, resulting in increased resistance, affecting the normal battery charging and discharge, it must be promptly processed.
Q:What battery does the van use?
The most obvious feature of lead-acid batteries is the top of the plastic cover can be unscrewed, there are ventilation holes above. These fillers are used to fill pure water, check the electrolyte and the use of exhaust gas. In theory, lead-acid batteries need to check the density of each electrolyte and the level of liquid, if there is a need to add distilled water. But with the upgrading of battery manufacturing technology, lead-acid battery development for the lead-acid maintenance-free batteries and colloidal maintenance-free batteries, lead-acid batteries do not need to add electrolyte or distilled water. Mainly the use of positive electrode to produce oxygen can be absorbed in the negative oxygen cycle, to prevent water reduction. Lead-acid water batteries are mostly used in tractors, tricycles, car start, etc., and maintenance-free lead-acid battery wider range of applications, including uninterruptible power supply, electric vehicle power, electric bicycle batteries. Lead-acid batteries according to the application needs to be divided into constant current discharge (such as uninterruptible power supply) and instantaneous discharge (such as car to start the battery).

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords