Fire Fighting Truck HOWO 4X2 for ce
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 PCS
- Supply Capability:
- 1000 PCS/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Fire Fighting Truck HOWO 4X2 for ce
Basic Info.
Model NO.:Sino FFT
Type:Tanker
Certification:ISO9000, CCC, TS16949, EPA, EEC, RoHS, CE
Volume:3001-5000L
Emission Standard:Euro 2
Transmission Type:Manual
Engine Type:4 Stroke
Payload:20T
Fuel:Diesel
Drive Wheel:4×2
Horsepower:251-350hp
Condition:New
Color:White, Yellow, Blue... as You Like
Gine Brand:Cummins
Horse Power:250-350HP
Vehivle Nme:Refregirator Truck, Freezer Van Truck
Export Markets:Global
Additional Info.
Trademark:UG
Packing:Naked and Waxed Before on Board
Standard:CCC, ISO9001
Origin:Shenzhen, Guangdong, China
HS Code:8705909990
Production Capacity:1000unit/Month
Product Description
1 Modle: SINOTRUK
2 Water and Foam: 6: 2
3 Gunshot: >55
Our company is a special purpose vehicle manufacturer that has the capacity of self-research and development
The main products are
1. Chemical liquid tank truck
2. Fire engine truck
3. Truck mounted with crane
4. Heavy duty truck, dump truck
5. Water truck,
6. Fuel tanker,
7. Van truck, insulated truck, refrigeration truck
8. Fecal suction truck, sewage suction truck,
9. Concrete mixer truck,
10. High-altitude operation truck,
11. Self-loading garbage truck, garbage compactor truck, sealed garbage truck,
12. Bulk cement truck,
13. Low plate semi-trailer, oil semi-trailer, van semi-trailer, fence semi-trailer, Bulk cement transportation semi-trailer, container Semi-trailer, chemical liquid transport semi-trailer, etc more than 300 types in total.
Model QDZXF Flow 60L/s/1.0MPa 30L/ s/2.0MPa | |||
Basic Information | |||
Vehicle name | Water fire truck | Chassis | ZZ1256M4646F |
Outline size(L×W×H) (mm) | 9875×2490×3490 | Cargo inline size(L×W×H)(mm) | / |
Rating mass(kg) | 15000 | Empty mass(Kg) | 13050 |
Full mass(kg) | 28050 | Emission standard | Euro 2 |
Engine Information | |||
Model | WD615.61A | Type | Water cooling in-line six-cylinder turbocharged diesel engine |
Power/displacement(KW/ML) | 193/9726 | Manufacture | Weichai Power Co., Ltd. |
Chassis Information | |||
Wheelbase(mm) | 5500 | Axle load(kg) F/R | Front :7000/Rear :25000 |
Tire | 11.00-20,11.00R20 | Max speed (km/h) | 85 |
Front overhang(mm) | 1560 | Rear overhang(mm) | 2520 |
Front track(mm) | 1939 | Rear track(mm) | 1800 |
Approach angel(°) | 15 | Departure angle(°) | 12 |
Steering | Power steering | Brake | Air brake |
Cabin | Straight head 2 rows 4 doors | ||
Special function | |||
Tank capacity(L) | Water tank: 10000L Foam tank: 2000L | ||
Fire monitor | Model PL48-64D dual-use monitor Water Range ≥60m/1.0MPa Foam range ≥50m/1.0MPa | ||
Fire pump | Model CB10/60 Flow 60L/S Pressure 1.0MPa |
- Q: Who invented the fire engine?
- One of the world's first fire engines was commissioned in 1518 by the German city of Augsburg, which was made by Anteneh Blater, a craftsman of metalwork. Little is known about the details of the fire engine. According to the book "history of Augsburg's technology", the fire engine was built on a large water pump operated by a lever. Its power is to draw with horses.
- Q: Fire engine fire pump pressure is low, what's the matter?
- Now the pump power is only 85.95KW, pump the water from the water surface to enhance the height of 200m, although 86KW a lot higher than that of the 69KW power, but with the increase of mechanical lift, efficiency will be reduced, the head loss will increase, the amount of water it will not be able to power and lift the proportion, can only reach 20L/S. According to the law of conservation of function, that is, regardless of the mechanical efficiency and head loss, the water discharge at the height of 200m should reach 40L/S. At the very least 140kW power, 86KW, of course, is far from, so the traffic is small.
- Q: How to arrange the fire lane in the multi story public building with inner courtyard?
- The purpose of setting up fire lanes is to ensure that fire engines are unblocked and reach the fire site in time of fire and extinguish the fire in time.A fire lane through a building should be provided when the length of the street along the street exceeds 150m or the total length exceeds 220m
- Q: What regulations should the fire engine climb up the operation site?
- Fire climbing venues and other requirements: between fire uprise venues and the workshop, warehouse, civil buildings should not interfere with setting fire truck operation obstacles such as trees, overhead pipeline and garage entrance; the site and building structure, pipeline and Angou, should be able to withstand the heavy fire pressure range of buildings and fire engines; a corresponding operation site, should be set up through outdoor stairs or through the entrance staircase. High-rise buildings should be at least along a long edge or around the length of the l/4 and not less than a long side length of the bottom continuous arrangement of climbing fire operation area, the scope of the podium depth should not exceed 4m. The height of the building is not greater than 50m construction, continuous layout climbing fire operation site is difficult, can be arranged at intervals, but the distance is less than 30m, and the total length of climbing fire operation site should comply with the above provisions.
- Q: How many years is the scrap time of fire engines?
- Special vehicles such as cranes, fire engines, drilling cars and so on, can be appropriately endorsed for the December 31, 2099 automobile scrap standard (revised in 1997) (national economic and Trade Commission No. [1997]456) in 10 years.In January 14, 2013, the website of the Ministry of Commerce issued 14 "compulsory retirement standard provisions" clear, according to the motor vehicle use and safety technology, emissions inspection status, implementation of the national mandatory retirement of vehicles to be scrapped. The regulation will come into force on May 1, 2013.
- Q: Why can the fire engine run through the red light?
- Because they are for public service, they may race against time to save lives.But in case you hit a car or a person who drives or walks normally, you should be responsible for it!
- Q: How wide is the driveway of the fire engine?
- B indoor fire channel width5.3.14 unless otherwise specified in this specification, the total width of the evacuation walkway, exit exit, evacuation stairway, and room evacuation door in the building shall be calculated and determined.The net width of the safety exit and room evacuation door shall not be less than 0.9m, the net width of the evacuation walkway and the evacuation stairway shall not be less than 1.1m, and the unit shall not be more than 6 layersThe minimum net width shall not be less than 1.0m when the handrail is set on one side of the evacuation staircase.
- Q: Why is the fire engine red?
- When sunlight shines on objects, various objects absorb and reflect different wavelengths of lightVarious colors are formed. In short, if an object reflects one or more of the light of the sun, it absorbs itMore than light, then the object presents the color of the reflected monochromatic or polychromatic light. In visible light, light of red lightThe longest, but the smallest angle, easily passes through the water, the rain, the dust, and the mist. Orange and yellow light are not afraid of obstruction,Able to penetrate these objects.
- Q: Is there a "fire passage and entrance"?
- Give you fire technical specifications for fire passage regulations:The following provisions of the code for fire protection of building design6 fire lane6.0.1 street should be considered within the road fire trucks, and the distance between the center of the road should not be greater than 160.0m. When the length of the building along the street portion is greater than 150.0m or the total length is greater than 220.0m, a fire lane through the building shall be provided. When there is a problem, the ring fire lane should be provided.
- Q: Obstructing fire engines, fire boats to perform the task of administrative punishment case is hindered and special
- (four) bury, occupy or cover a fire hydrant or occupy fire prevention space;(five) occupying, blocking or blocking the passage of fire engines and impeding the passage of fire engines;(six) a crowded place is set up on doors and windows to influence the escape and fire rescue;(seven) failing to take timely measures to eliminate the fire hazards after being notified by the fire protection institution of the public security organ.Individuals who have one of the second items, third items, fourth items or fifth acts mentioned in the preceding paragraph shall be warned or fined not less than five hundred yuan.