elevator parts low cost load cellType ECW-P2 Elevator Load Weighing Device

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

elevator  parts low cost load cell
Type ECW-P2 Elevator Load Weighing Device

INTRODTION MANUAL

This system is applicable to all elevators with movable car platform in need of overload signals. This device is of extremely high performance-price ratio. This appliance is to overcome the inherent disadvantage of the mechanical overload switch and to replace it.

Main characters:

1. Working in a contactless and inductive way. No mechanical movement itself. Being directly installed in the original place of overload switch. No necessity of changing the mechanism of elevator car.

2. Adopting strong inductive magnet, improving the anti-interference of the system to the utmost.

3. The electrical property is in compliance with the standard of the International Electro-technical Commission (IEC).

4. Rated relay dynamic open, overload relay -dynamic close and output-break are easy for customers to use.

5. More accurately positioning, small overall size, easy installation and adjustment, simple structure and low price.

Technical Specification:

Application Range

Applicable to all elevators with movable car platform in need of overload signal with a inspection clearance of 815.

2

Sensitivity

Overload turning pointRated load adjusting point±0.05

Rated loadoverload retention gap0.50mm

3

System Error

1.5% (540)

4

Output Mode

1 pair of relay dynamic CLOSE or dynamic OPEN contacts respectively with the capacity of DC/AC 48V/500mA.

5

Operation Ambient Temperature

-2555

6

Power Supply

AC/DC 24V(±10%)/15mA. The operating current of the whole machine100 mA.

7

Install Position

Movable elevator car platform

8

Overall Size

Column of Φ24×83 mm

Working Principle:

This system weighs the elevator car load based on the principle of the elastic deformation of movable elevator car platform caused by loading with the HALL sensor measuring the change of displacement, fulfilling the aim of load weighing.

Installing Method:

Adjustment

1. Please refer to the above figure to install this device with the connecting support (made by the customer himself) closing the middle part of the car platform as near as possible.

2. Let the magnet adhesive on the car platform with the marking-face right facing the induction point of the device.

3. Install and adjust this device so that the magnet on the car platform aiming at the center point of its upper face. Meanwhile, assure the end face of this device in parallel with that of the magnet.

4. When elevator is of rated load, adjust this device up and down to make the indicator just turn green, yellow one (red one +green one) turn down , at this time, fasten this device and the adjustment is finished.  

5. At the time of overload, indicator of this device keeps yellow (green+red)  

The principle of system wiring:

Wire

Function

    Explanation

Red, black

System Operating Power

Operating Power   AC/DC24V(±5%)/100mA

Yellow, White

Overloading relay dynamic Close contact

Contact Capacity:

DC/AC 48V/500mA

Blue, green

Overloading relay dynamic Open contact

Green, white

Overloading relay dynamic break contact

Attention : Output wire of this device must not be connected with external power supply to avoid everlasting damage.

Others:

Accessory: Inductive magnet [20×20×4mm3]  1 piece  Fastening Nut: 2 sets

If there is any abnormality during adjustment or operation, contact our company directly.

Attention: The inductive magnet is specially made of rare earth magnet with strong magnetism for this product. Take special care in the course of installation. Don’t let it close to the high temperature above 100℃ to avoid demagnetization and our company will not be responsible for the personal hurt and equipment damage arising from this.


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How many years does the construction elevator usually use?
More than eight years will not give you the advice to get the factory refurbished
Q:Can construction elevators be taken by people or by goods
The construction elevator can be taken either by person or by cargo Material hoist (dragon door frame, well frame) can be carried only, not by person
Q:Is the construction elevator the same as the construction elevator
The construction elevator is the standard name, there are national standards, including the elevator, the people's elevator, the construction elevator is the popular term, the general point is the people's elevator not including the elevator.
Q:Why is the construction elevator not so close to the structure?
The distance between the moving parts and the building and the fixed construction equipment shall not be less than 0.25 m. The main thing is to prevent the person from the point of view. For example, workers are on the third floor to look down, hanging cage, where is the result now hanging basket is go down from the fourth floor, if not the 25 cm, likely to brush "cut".
Q:How is the construction elevator installed
Construction elevator installation 1) the location of the elevator depends on the condition of the site and the equipment, so as far as possible, stay away from the overhead line and keep the safe distance specified. When the elevator is running, there is a lot of danger and should be avoided. 2) the order of installation is: 3) place the chassis on the base and the base pre-buried bolt, and the platform is placed on the chassis, and the basket is placed in the middle of the chassis. 4) to install the standard section, each installation of two standard sections (usually less than 8m) to be temporarily fixed. The wire rope shall be used for the use of the temporary cable, and the joints and supporting points shall be bolted and not tied with the lead wire. 5) the installation should alternate between the two columns. Node bolt specification must according to the aperture matching, not packing, found that the aperture position at the time, can not arbitrarily expanding, more can't to lead wire bundle, instead to avoid loose node deformation. 6) when installing the standard section, pay attention to the vertical degree of the guide, and the line of the guide line should not appear in the line of folding and too big clearance to prevent the collision from running. 7) when construction site conditions permit, it can be assembled on the ground and then hoisted on the whole to reduce the height of the work. Due to the design of the frame, the stress condition of the construction is only considered, so before the whole moving up, the counter can be temporarily strengthened to enhance the bending capacity of the nodes.
Q:The maximum allowable deviation of the vertical is the vertical degree when the construction elevator is installed
5 kinds of circumstances. 1: the height of the elevator guide frame is less than 70 meters, and the vertical deviation should not be greater than one in 1000 of the height of the guide frame. (assuming the rail frame is 70 meters high, the deviation cannot be greater than 70mm) 2: the rail frame is greater than 70 meters and is less than 100 meters, and the deviation is less than or equal to 70 mm. 3: the guide frame is larger than 100 meters and is less than 150 meters. The deviation is less than or equal to 90 mm. 4: the guide frame is larger than 150 meters is less than or equal to 200 meters. The deviation is less than or equal to 110 mm. 5: the guide frame is greater than 200 meters, and the deviation is less than 130 mm. This is based on the requirement of 5.2.2.1 from GB10054 to 2005. (it used to be a direct copy.)
Q:When does the construction elevator take off?
If the elevator is installed later, can the construction elevator be demolished at this time? It should not be removed because the elevator is used by the local technical supervision bureau. The unused elevator will be fined 5-200, 000 fine and the elevator installation unit will be revoked. No one will take that risk! It is usually done on rooftops, indoors and outdoors, and the materials have been transported upstairs. It is best to be able to remove the elevator when it is finished, so it doesn't affect the progress.
Q:The difference between the derrick and the construction elevator?
They're the same. HAULOTTE answer for you
Q:Construction site construction elevator and tower crane, which unit security check and acceptance?
Different but most likely is the construction elevator
Q:The tower crane is on a surface with the construction elevator, and only 2 or 3 meters away. Is that allowed
Cranes and elevators from very close, may be the reason for the sites or the position is not reasonable, so close to the distance as long as you ensure the tower crane and tower crane arm when rotating to the above the elevator after satisfying the end, must keep more than 2 meters with elevator recent distance. Or you can refer directly to the tower crane safety code, GB5144-2006.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range