• CSL Automatic Sliding Door System 1
  • CSL Automatic Sliding Door System 2
  • CSL Automatic Sliding Door System 3
CSL Automatic Sliding Door

CSL Automatic Sliding Door

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or L/C
Min Order Qty:
1 Set set
Supply Capability:
2000 Sets Per Month set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Quick Details of CSL Automatic Sliding Door:

 

Place of Origin: Shenzhen China (Mainland)

Open style: Sliding

Type: Door

Position: Exterior

Window Material :Glass

Surace Finishing : Finished

 

Packaging & Delivery of CSL Automatic Sliding Door:

Packaging Detail: Carton

Delivery Detail:15-45 days

 

Specification of CSL Automatic Sliding Door:

Radar, 2 sets, BEA, MW-6 microwave/infrared

Safety beam, 1 set, BEA, BCL Infrared

Sensor open mode: infrared sensor or microwave sensor is used

Effective monitoring area: maximum at 3 x 1.5m, minimum at 1 x 0.3m

Coded lock open mode: advanced code identification system is used to improve the security of the sliding door

Card Swiping Open Mode

Button open mode elbow-touch, foot-touch and magic touch are used

Selected functions:

Manual open, automatic, partial open, hold open, one-way access and night lock

 

Adjustment of operating parameters:

Reset: back to the initial #118 value

Opening speed: 0.4 to 0.7m/s (adjustment range)

Closing Speed: 0.3 to 0.6m/s (adjustment range)

Partial opening width: 25 to 99% (adjustment range)

Open time for maintenance: 0 to 10s (adjustment range)

 

Technical parameters:

Applied voltage: 220V/50Hz/5A

Rated power: 100W

Maximum power consumption: 200W

Maximum driving force (static): 300kg

Ambient temperature: -25 to +75°C

Relative humidity: 65% maximum

Maximum clear opening width: 3,000mm

Automatic door wing largest load: 100kg x 2

Running noise: ≤40db

 

 

 

 

 

Q:How does the automatic door work?
The automatic door system consists of sensors, controllers, motors, rails and doors. The sensor is now mostly microwave sensors, the equivalent of a radar, when there is a movement near the object, it sends a signal to the controller. Controller is generally used PLC programming microcomputer, we can adjust the controller through the door to open the door when the speed. The controller controls the operation of the motor and the motor is connected to the door by means of a toothed belt and a door connection (connected by a hanging part). There is a pulley on the hanging part. The door is hung on the guide rail by a pulley on the hanging part Can slide. The rails are fixed on the beams and the beams are firmly connected to the walls on both sides. The gravity of the door is supported by the guide rail, and the belt pull door slides left and right on the rail
Q:Automatic door can not be opened normally how to do?
Automatic door can not be closed normally There are two cases, one is about the door action, but off a little to re-open. The other is the automatic door is always open state, can not be closed, or always keep the state closed, can not open. The first kind: the door movement, but can not close the situation, this reason is the sensor has a door signal input, that is, sensors within the scope of interference there are, such as: direct sunlight, active objects, there is not Stable light source and so on. It is possible to test whether or not the automatic door can not be turned off by turning off the sensor signal line by the sensor's interference signal. The second type: automatic door always remain open, causing the automatic door failure may be due to sensor damage, always have to open the door signal input to the automatic door controller, may be automatic door remote control or mode switch to adjust the open state, If the access control system is installed, it may be that the access control system is damaged. In addition, the automatic door can not normally open and close, you can also refer to the following automatic door repair solution: ● Cause The top of a door is in contact with the beam Treatment: adjust the gap between the door and the beam ● Cause The two doors are in contact with the ground rail Remedy: Adjust the door height ● Cause three doors derailment Remedy: Re-place the door in the track ● Cause The four doors are not vertical Treatment method: adjust the location of the track ● Cause Five sensors are faulty or are not wired to the hub Approach: 1. Replace the sensor if the sensor fails 2. Check that the sensor is connected to the hub Through the above analysis, should be able to basically solve the automatic doors can not normally open the automatic door failure, and in the actual automatic door repair should be simple and complex, first remove the simple reasons of automatic door failure, and then gradually troubleshoot other failures.
Q:where should i start to troubleshoot the problem or do I need to take it into the dealership?
With the information you have given, it sounds like 2 different items are shorting. Those items usually have seperate fuses in the fuse panel. I would take it to the dealership versus the Mobil gas station on the corner, if you know what I mean. I have forgotten, some of the new car stereos are triggered to shut off, when the door opens (after the key is removed, it will stay on). You could have some moisture in the door panels, causing a short. Just guessing, because we are about to float away. GOOD LUCK!
Q:Like in Shopko the doors that swing out how do they work. How do they swing out automatically?
There is a sensor that detects someone approaching the door. It could be a switch in a floor mat or an ultrasonic device that receives an echo from an approaching customer. The sensor operates some sort of electric motor that drives a mechanism that opens the door.
Q:I was the first time to install automatic doors, today will automatically search the door motor on the ground wiring test machine, the motor has been turning non-stop, I do not know what reason, ask you big God mention, be grateful.
Normal. After the installation of automatic doors to carry out a stop device, the resistance will make the motor reverse door. You have no resistance on the ground, so it will go down.
Q:Induction of automatic doors why no one will open their own, the company's sensors are automatic glass door, someone in the past or out will be open, why no one will pass through the open automatically?
The problem is largely due to the high sensitivity of the probe, you can observe the inside and outside the probe, when the door closed when you look at which probe indicator (usually bright red) from green to red And some are orange), which is the light of which is the problem, the solution is also very simple, you just remove the probe shell, the circuit board on the potentiometer can be adjusted counterclockwise. Or the antenna up breaking off like!
Q:What is the motor device of the induction automatic door?
Induction automatic door motor connection control system, when the sensor detects someone movement, the controller drive the motor is turning the door, no signal when the motor reverses the door.
Q:Elevator automatic door induction has a blind spot is it true?
it is true. Blind Location: At present, the domestic use of the elevator there are two, the first is the touch plate elevator, that is, in the elevator door has a prominent touch panel, when there are objects touch the touch panel, the elevator door will automatically bounce; For the light curtain elevator, is installed in the elevator door with two ray sensor device. Although the two elevators are equipped with induction devices, but the blind area still exists, to light curtain elevator, for example, the area can not cover the entire elevator door, in the bottom of the door there are ten centimeters blind spot. In other words, the area of the object, the elevator door sensor
Q:How is my world automatic door?
Dig a 2 * 3 lattice on the ground
Q:I have a 1997 Dodge ram 1500 and on the driver side the door will not lock with the locking switch. the lock motor runs because i can hear it and the passanger side door locks but the driver side wont. Any Suggestions on how to fix this?
Remove the door panel and check the linkage between the linear actuator (power lock) and the mechanical lock, you'll probably find the linkage is broken or has become disconnected.
Ningbo Ownic Automatic Doors Co., Ltd. is a pioneer in the automatic door industry. Specialized in the R&D, manufacture and sale of automatic doors, OWNIC is committed to providing overall solutions of architectural door control / hospital cleanliness / industrial purification to meet users' demands for security, reliability, aesthetics, comfort and durability. Now our company becomes the pioneer of building entrance space aesthetics. Strong brand influence and the accumulation of decades of professional experience, as well as higher awareness, satisfaction and reputations from customers around the world prove that we are building solid and credible strategic partnerships in the field of architectural entrance technology. We provide a full range of innovative and high-quality products and services to satisfy our worldwide customers' requirements of passing capacity, security performance and artistic aesthetics. With rich experience, innovative technology, superb techniques and worldwide marketing network systems, we are always ready to provide the best solution that truly meets your need. OWNIC relies on internationally advanced technology and equipment, learns the popular thought of international architectural design, and customizes precise and professional planning and positioning of production. We strictly abide by Swiss company SGS ISO9001:2008 international quality certification system standardized production management to create a series of high-quality products which have stable operation, silent tuning, safe and convenient usage, and intelligent and humanized design. OWNIC automatic door applications of a wide range of Business Series are widely used in banks, hotels, office buildings, supermarkets, etc. Our Medical Series products are used in thousands of hospitals all over the world. Our Industrial Series products are adopted by pharmaceutical factories, IT electronic industry and research institutions.

1. Manufacturer Overview

Location Ningbo, China
Year Established 1995
Annual Output Value Above US$ 100 Million
Main Markets Europe; North America; Mid East
Company Certifications ISO 9001:2008;SGS

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Ningbo
Export Percentage 60% - 80%
No.of Employees in Trade Department 100-500 People
Language Spoken: English; Chinese
b)Factory Information  
Factory Size: Above 100,000 square meters
No. of Production Lines Above 3
Contract Manufacturing OEM Service Offered; Design Service Offered
Product Price Range High; Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords