China TH-440 Full-digital Ultrasound Diagnostic System FOR Medical Apparatus

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 pc
Supply Capability:
100000 pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Features:
* Multi-application: abdomen, OB/GYN, vagina, small parts, urology, peripheral vessels,
cardiac, rectum, pediatric, biopsy
* High-precision DBF
* PC platform
* 15 inch LED display
* Multi-frequency transducer series
* Max frequency up to 10MHz
* English, French, Spanish, Germany, Italian, Russian, Portuguese interface
* Supportive of all PC printers and video printers
* 3D Function
* Built-in battery(around 2 - 3 hours)
Standard configuration:
TH-400 main unit
15 inch LED montor
Two transducer connectors
THI
Permanent storage of 5000 images
Max 512-frames of Cine Loop
Two USB ports
DICOM 3.0
Measurement & calculation software packages
Electronic convex array transducer: CA3.5MHz/R50 (2.0/3.0/3.5/4.0/4.5MHZ)

Options:
Electronic linear array transducer: LA7.5MHz/L40 (6.5/7.0/7.5/8.0/10.0MHz)
Electronic endocavity transducer: EV6.5MHz/R10 (5.5/6.0/6.5/7.0/7.5MHz)
Electronic micro-convex array transducer: CA3.2MHz/R20 (2.5/3.0/3.2/4.0/4.5MHz)
Built-in 160/320/500G HDD(option)
Needle-guided brackets
Footswitch
Mobile trolley
Technical Specifications:
General Descriptions
Imaging mode: B, B+B, B+M, M, 4B, 9B
Gray scale: 256
Display: 15″LED
Transducer frequency: 2.0 ~ 10MHz
Transducer connector: 2
Beam-forming: DBF (Digital Beam-forming)
DRF (Dynamic Receiving Focusing)
DFS (Dynamic Frequency Scan)
RDA (Real-time Dynamic Aperture)
DRA (Dynamic Receiving Apodization)
Scanning angle (°) : from 24 to 156.6 (depending on transducers)
Scanning depth (mm) : from 20 to 250 (depending on transducers)
Image Processing
Pre-processing: 8-segment TGC
gross gain
dynamic range (≥120db)
Pre Gray
smooth
acoustic power adjustment
scanning angle selection
Post-processing: edge enhancement

frame correlation
line correlation
γ-correction
contrast
brightness
black-white reverse
left-right reverse
up-down reverse


Functions
Cine loop: 512-frame cine loop memory, depend on the resolution
Storage media: permanent storage of 5000 images, USB, built-in 160/320/500GB HDD
(option)
Zoom: real-time partial zoom, up to 10 times
Measurement & Calculation
B-mode: distance, circumference, area, volume, angle, residual urine volume,
histogram, profile
M-mode: distance, time, velocity, heart rate
Software packages: abdomen, gynecology, obstetrics, cardiology, small parts, peripheral
vessels, orthopedics, urology
Others
Peripheral port: Video output 1(option)
USB port 2
DICOM3.0 1
Power supply: 100~240V±10% 50/60HZ
Net weight: 4Kg
Dimension: 362mm x 340mm x 60mm
NOTE: specifications subject to change without prior notice.
SCM Version


Features:
* Multi-application: abdomen, OB/GYN, vagina, small parts, urology, peripheral vessels,
cardiac, rectum, pediatric, biopsy
* High-precision DBF
* Multi-frequency transducer series
* Max frequency up to 10MHz
* English, Chinese interface
* 15 inch LCD screen
* Built-in battery(around 3 - 5 hours)
Standard configuration:
TH-400 main unit
15″ LCD monitor
Two transducer connectors
2 USB port
Measurement & calculation software packages
Electronic convex array transducer: CA3.5MHz/R50 (2.0/3.0/3.5/4.0/4.5MHZ)
Options:
Electronic linear array transducer: LA7.5MHz/L40 (6.5/7.0/7.5/8.0/10.0MHz)
Electronic endocavity transducer: EV6.5MHz/R10 (5.5/6.0/6.5/7.0/7.5MHz)
Electronic micro-convex array transducer: CA3.2MHz/R20 (2.5/3.0/3.2/4.0/4.5MHz)
Needle-guided brackets
Footswitch
Mobile trolley

Technical Specifications:
General Descriptions
Imaging mode: B, B+B, B+M, M,4B
Gray scale: 256
Display: 10″non-interlaced
Transducer frequency: 2.0 ~ 10MHz
Transducer connector: 2
Scanning depth (mm) : from 20 to 250 (depending on transducers)
Measurement & Calculation
B-mode: distance, circumference, area, volume, angle, residual urine volume,
histogram, profile
M-mode: distance, time, velocity, heart rate
Software packages: abdomen, gynecology, obstetrics, cardiology, small parts, peripheral
vessels, orthopedics, urology
Others
Peripheral port: video output 1
USB port 2
Power supply: 100~240V±10% 50/60HZ
Gross weight: 4Kg
NOTE: specifications subject to change without prior notice

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Does the telecom fiber junction box have radiation to people?
Telecom fiber junction box without radiation, no harm to the human body please rest assured. I hope my answer to help you, if in doubt, please continue to consult Guangdong Telecom customer service.
Q:Help EMA (electromagnetic ultrasound) master; reward 20 points
Hertz also used a variety of experiments to prove that not only the nature of electromagnetic waves and the same light waves, and the propagation speed is the same, and can occur reflection, refraction, interference, diffraction and polarization phenomena. In other words, the electromagnetic wave obeys all the laws of the general wave. 5. According to Maxwell's theory of electromagnetic fields, the changing electromagnetic fields can be excited by each other, so that the electromagnetic field changes from the field source, from near and far to the surrounding space spread out to form electromagnetic radiation. This change in the electromagnetic field at a certain speed in the form of waves to spread around, it is called electromagnetic waves. Theoretical Basis of Electromagnetic Ultrasonic Testing Technology     
Q:In front of the computer for a long time what harm?
Computer host, monitor, mouse, keyboard and the surrounding equipment will produce radiation, eyes can not see, hands touch. According to scientific research shows that: computer-generated low-frequency electromagnetic radiation on the human body caused by the damage is hidden, the accumulation of people often (long-term) in the ultra-strong computer low-frequency electromagnetic radiation environment using the computer, leading to dizziness, headache, Tinnitus, brain cancer, breast cancer, blood pressure, abnormal blood pressure, chest tightness, bradycardia, bradycardia, heart failure, loss of vision, loss of appetite, fatigue, memory loss, some people hair loss, leukopenia, immunity, cataract, leukemia, , Heart rate reduction, sinus heart rate, male sperm quality, some women menstrual disorders, maternal abortion, stillbirth, fetal malformations, reproductive lesions, genetic lesions, cancer and other terrible diseases. People in the operation of the computer, the face will absorb a lot of electromagnetic radiation particles, often radiation will appear facial rash.
Q:Computer room office, there are two switches and a telecommunications fiber cabinet, Will the radiation big 30
So it seems that radiation is not small, it is best to wear radiation suits, this will avoid long-term exposure to the body and cause harm!
Q:TV radiation
Q:How much electromagnetic radiation is the strength of the floor?
If simply from the data and the impact is concerned, of course, your home wires near the electrical equipment between the electromagnetic radiation to be larger. For example, a 6KV high voltage cable from my house about 1 meter from the distance through the balcony after the electromagnetic field strength and crosstalk value of my refrigerator near the refrigerator near the strong electromagnetic field. It should be noted that this level of electromagnetic field on the basic health of the basic no effect, not to mention people are active, as your home opposite the electric door, but do not need to consider.
Q:What does welding arc radiation mainly include?
General arc welding arc temperature can be as high as 5000K or more, will produce a strong arc radiation. Welding arc radiation mainly includes: visible radiation, infrared and ultraviolet light radiation. The light source wave range between 102 ~ 106A. The size of the general arc welding radiation is related to a variety of factors such as the metal vapor in the arc, the length of the arc, and the size of the welding current. When the welding current or arc voltage is greater, the stronger the welding arc, the greater the arc radiation. Welding arc radiation and other radiation sources, the ray intensity will increase with the distance gradually decreases, the decline is proportional to the square of the distance. Its harm is as follows: For example, arc radiation produces far more intensity than the human eye can bear. Visible light, with ultraviolet and infrared. When the arc radiation for a long time to the human body, may be absorbed by the body tissue caused by the body tissue heat, photochemical and ionization, resulting in acute or chronic injury to human tissue, especially in ultraviolet and infrared damage the most serious, and this The species is reproducible. (1) UV rays can cause damage to the skin and eyes. UV damage to the eyes is caused by electro-optical ophthalmia. (2 Infrared rays cause the body tissue to cause heat, and the eyes are exposed to infrared radiation, which can cause burns and burning quickly, forming a sense of flashing sensation, and the effect of argon arc welding is greater than that of hand arc welding. Strengthen the various security protection, in order to "welding arc radiation" damage to a minimum.
Q:Do not work on household appliances affect pregnant women do
What is the impact of household appliances on pregnant women: TV Pregnant women appropriate to watch TV beneficial physical and mental health, it can regulate the mood, so that pregnant women have a good mood. In general, the TV factory in the factory have done a rigorous testing, the ionizing radiation rate of not more than 0.5 millramo, not to cause radiation hazards to people. But the radiation itself is an energy, when the energy is absorbed by the body tissue, the molecules of the molecules will occur ionization, that is, energy into another form, and this energy still need to be released, and thus in the absorption It causes other reactions, the so-called "secondary effect" of the energy transfer, will be harmful to the human body. According to reports: the United States 18 in the screen before the work of pregnant women, 7 years of miscarriage, 1 premature birth, 3 people produce deformed fetus. Investigation of 56 early and mid-term pregnant women, about 9% of adverse reactions, adverse reactions are dizziness, fatigue, loss of appetite, mood irritability, anxiety, emotional tension, scientists about 20 hours a week close to the screen 70 A number of pregnant women conducted a survey showed that 20% of pregnant women had spontaneous abortion.
Q:Hebei Yun Yip Hospital four-dimensional color Doppler ultrasound check it?
Four-dimensional color Doppler ultrasound is an ultrasonic inspection equipment, it is based on excellent ergonomic design,
Q:Light, heat, sound, electromagnetic waves, these radiation, which radiation damage
Of course, electromagnetic waves, and electromagnetic waves is a kind of light, but the radiation is greatest, the sound and heat radiation is small, but other forms of energy Shanghai big!

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range