Features tubular motor for automatic window and garage door: 
1) Voltage: 230V/50Hz 
2) Input power: 117W/ 215W 
3) Current: 0.49A /0.92A 
4) Speed: 12/16/25rpm 
5) Torque: 10/15/20/30/40/50N. M 
6) Working duration: ≥ 4min 
7) Insulation classification: B 
8) Protection classification: IP44 
9) Certification: CE, TUV, CCC, ISO9001-2008 ROHS, 

Standard tubular motor for automatic window and garage door: TUV, CE, CCC, UL 
Productivity: 300, 000pcs/year 
Origin: China 
Packing: 6pcs/ctn, 1pc/colour box 
Min. Order: 500pcs 
Transportation: By sea or by air


Outer packing tubular motor for automatic window and garage door: 
6pcs/carton with foam in it


CE, TUV, RoHS, CCC, ISO9001 certificated, 
Safety, Energy saving, High efficiency, Long life time, 
Low noise, Low temperature increasing, Low maintenance cost. 


The ideal tubular motor for automatic window and garage door, roller shutter and awning etc, with TUV, CE, ISO9001-2008 certificates, Low noise, efficient, energie saving, high Efficiency, long time life 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Can two phase ac motor not be able to install governor?
Two phase ac motor can be equipped with governor; Ac motor speed regulation by changing the power supply frequency of ac motor, the extreme logarithm and the slip ratio, etc., to realize the speed adjustment technology.
Q:How to control ac motor with single-chip microcontroller
First of all, you have to make sure that you have a two-way flow of alternating current motors. For example, using a single piece of the triode drive relay to control the motor's positive and backward rotation, as in the case of the main parasymmetrical single tap. The problem with this control circuit is that you can't control the motor stop! Moreover, the steering is controlled when the motor is rotated The motor may cause damage due to inertia. In the figure, the added level 1 stop control (1) (2), and steering control besides can control the motor stopped, also can be in to control motor rotation to insert the stop control, avoid damage to the motor inertia torque motor. Of course, if you are using two limit switches to control the motor's one-way work, you can use the image above.
Q:Is permanent magnet synchronous linear motor is ac motor or dc motor?
Whether the permanent magnet synchronous motor and electric field, as a motor stator will pass into the symmetrical three-phase alternating current (ac), as a generator, the stator is a three-phase alternating current, so it is ac motor. Haha, hope can help you!
Q:The ac motor with more than one kilowatt will be activated by the launcher
1, when the following conditions are met, the motor shall be fully pressed: When the motor starts, the voltage of the distribution bus is in accordance with the provisions of article 2.3.2 of this standard: Mechanical energy can withstand the shock torque when the motor is fully pressed. There is no special provision for the starting mode of the motor. When it is not in accordance with the condition of full pressure starting, the electromotive force is suitable for the starting up, or the other suitable starting way. The starting mode of the motor should be coupled with the speed adjustment mode when the speed adjustment is required.
Q:Single phase single capacitance ac motor three wires wrong
1, 2, 3, leading-out terminal, respectively, two winding motor start and running windings, respectively, to start the capacitors, switches for positive and negative selection, generally start winding resistance is greater than (not less than the running winding. If the AC220 is AC220, the AC220 will not rotate, and the 1, 3, or 2 or 3 ends will function properly
Q:Is the servo motor alternator? What's the difference?
The servo motor has dc and communication. The typical difference is: The wiring of ac servo motor is a three-phase power line, and the encoder feedback line. Ac servo motor is no carbon brush, dc servo motor has carbon brush. To see whether it's communication or dc motors, it's simple: Look at the number, if it seems AC is communicating, DC is DC. Also, according to the power source, the communication is a three-compartment power line.
Q:Is the motor for general electric tools ac motor or dc motor?
Portable single-phase electric tool machine is series motor, more general application for alternating current (ac), but also runs on direct current series motor, the direct current (dc) will run according to the power supply is negative connection it is also different.
Q:What is the difference between alternating current motors and dc motors?
Upstairs is a little irrelevant answer, the first people ask is the difference, again is the motor, not the generator! How it works: Dc motor installed a constant magnetic field, after the stator coil zhongtong current is generated electromagnetic force, so they will move, but the direction of the electric current to change, so will generally use brush, contact with the terminal. So the cost is higher. It is commonly used in servo motor, measuring motor and excitation motor. The ac motor has only one winding and the rotor is squirrel-cage. When a single-phase sinusoidal current in the stator winding, the motor can produce an alternating magnetic field, the magnetic field strength and direction interplanting sine law of change at any time, but is fixed on the spatial orientation, say again so the magnetic field is alternation pulse magnetic field. This alternation pulse magnetic field can be decomposed into two at the same speed and direction of rotation are instead of a rotating magnetic field, when the rotor static, the two rotating magnetic field generated in the rotor torque of two equal and opposite, making synthetic torque is zero, so the motor can't rotate.
Q:How to control ac motors with dc 24V voltage
The 24V contactor is also very expensive, with intermediate relays, and then use the intermediate relays to control the contactor
Q:The converter can control which motors
Inverter is actually a inverter. It is the first alternating current into direct current. Then use electronic components to switch dc. Into alternating current (ac). General power larger inverter with silicon controlled rectifier. And an adjustable frequency device. The frequency adjustable within a certain range. Used to control the motor revolution. Revolution in a certain range is adjustable. Inverter is widely used in ac motor speed control. Variable frequency speed regulation technology is important development direction of modern electric drive technology, with the development of power electronic technology, ac frequency conversion technology from theory to actual gradually to mature. The frequency converter is not only smooth, the scope is large, the efficiency is high, the start-up current is small, the operation is stable, and the energy saving effect is obvious. Therefore, ac frequency conversion speed regulation has gradually replaced the traditional slip control of motor speed, speed control, dc speed regulating pole change motor speed control system, such as more and more widely used in metallurgy, textile, printing and dyeing, air conditioning, machine production line and building, water supply, air conditioning and other fields

1. Manufacturer Overview

Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range