• butterfly valveCenter lined disc Standard Structure: Butterfly Pressure: Low Pressure System 1
butterfly valveCenter lined disc Standard Structure: Butterfly Pressure: Low Pressure

butterfly valveCenter lined disc Standard Structure: Butterfly Pressure: Low Pressure

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 pc
Supply Capability:
9999 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Quick Details

Standard or Nonstandard: Standard Structure: Butterfly Pressure: Low Pressure Power: Manual Material: Casting Temperature of Media: Normal Temperature Media: Water Port Size: DN40-DN1200 Place of Origin: China (Mainland) Wafer type: butterfly valve Packaging & Delivery

Packaging Details: Plactic bag+Paper cover+Plywood cases 

Delivery Detail: Within 20 days 

Specifications

Wafer type lined butterfly valve 

1.Design standard:ISO,BS,API 

2.DN40-DN1200 

3.PN10/PN16/PN25 

4.Center lined disc 



Wafer type lined butterfly valve 


 


 


Technical Data


DN40-DN1200mm PN1.0-1.6MPa


General Design:ISO 5752 / BS 5155 / API 609


Body: Cast Iron, Ductile Iron, Carbon Steel, Stainless Steel


Seat: EPDM, PTFE, NBR,Viton


Stem: Stainless Steel, Steel,


Disc: Ductile Iron with Nickel Coating,Ductile Iron with Nylon Coating, Stainless Stee 304/316l, Alu-Bronze,Duplex steel


Flange Connection:DIN,ANSI,JIS,BS


 


Product Features


Wafer type flanged body style fit between FF or RF flanges


PTFE bushing ensure the maximum shaft support and centralized alignment


360°polished disc assures positive on-off


Hard-Backed Cartridge seat or Edge-Boot seat


The pin,spline or square connection are all available


Universal ISO 5211 mounting pad.


Q:I have put a new pressure valve and replaced both thermostat
If it is not overheating due to a stuck thermostat or bad heating element and you changed the TP valve then it is possible you have a problem with thermal expansion. When water is heated it expands and the more it is heated the more volume it will need to expand. Since the water heater and the piping are not designed to expand the water only has one place to go (well two if count the faucet) and that is out the TP valve. This problem is not uncommon and the solution is to have an expansion tank installed on the hot water heater in the piping near the tank.
Q:How do you draw the butterfly valve in the engineering drawing?
Butterfly valve there are many kinds of painting, mainly designed to draw on the staff, according to the design institute out of the icon.
Q:Why anti condensation of aluminum alloy anti condensation butterfly valve?
Anti condensation butterfly valve multi-level unique progressive contact seat design, the valve plate in close contact in the process of gradually seat, ensure good sealing performance while reducing unnecessary torque, and the butterfly plate of stainless steel and the inner parts, thereby prolonging the service life of the valve seat, has strong rust and corrosion function. Torque reduction enables the drive to be lightweight and miniaturized. Unique stem seal prevents fluid leakage.
Q:I HAVE A 2003 FORD EXPEDTION THAT IS IDLE ROUGH,AND WILL EVENTUALLY STALL. TODAY I FOLLOWED THE PCV VALVE HOSE TO THE BACK OF THE THROTTLE BODY AND NOTICED THERE IS A BIG HOLE ON THE ELBOW OF THE HOSE. HOW CAN I CHANGE IT? CAN I JUST FORCE THE HOSE OUT AND SIMPLY PUT A NEW ONE? BEEN HAVING THIS ROUGH IDLE /STALL PROBLEM FOR A WHILE I CLEANED IAC VALVE, THROTTLE BODY CHANGED THE AIR FILTER AND ALSO CLEANED THE MASS AIR FLOW SENSOR, I HAVE A P0171 system to lean(bank 1) code
just undo the clamps, and pull. it may need some wiggling and tugging, as its been on there for 9 years now without moving. put on your new hose, and replace the clamps, and youre done. next time, try not using all caps. it doesnt make us want to answer your question anymore just because its in caps, in fact, maybe a little less.
Q:I got my timing belt done on a 1999 Civic Si on September 26 @ 113,699 miles. at 116,9xx miles I bent a valve on my third cylinder. How likely is it that the timing belt is the reason why this happened? I heard that if the timing belt is a tooth or so off, it could bend a valve. So is it likely that this could have happened? Anyway to check?
If it was a timing belt issue it woudn't have only been one cylinder. And usually if it's only off by one tooth, it just runs poorly. IT has to be off by quite a bit, or the belt has to straight up break to bend a valve,, if that happened it would have made a horrible clanging noise repeatedly before it eventually sputtered out. the 1999 Si revs to what... 8000 rpms? You didn't happen to miss a shift and over-rev the engine, did you?
Q:Where are the exhaust valves, mud valves and butterfly valves?
The exhaust valve is suitable for the pipeline with working medium, so as to improve the efficiency of the water conveyance equipment and protect the pipe from deformation and rupture. Sludge discharge valves are suitable for use in floating waste water treatment plants, such as gypsum. Slag, scale power stations, smelters, sugar mills.
Q:can't locate freon intake valve for 03 jaguar an was wondering were it is located at
There is no Freon intake valve for an 03 Jaguar. Freon is R12 refrigerant and the vehicle uses an R134a refrigerant system. There is also no such thing as an intake valve on any vehicle refrigerant system. There is a high pressure port and a low pressure port. To answer your question: under the hood. Any other information would likely endanger your life, since this is obviously a DIY question and you lack the knowledge to safely recharge your vehicle's refrigerant system. R134a refrigerant, if inhaled, can kill you. Do not turn a DIY project into a DIE project. Leave the complicated stuff to the professionals.
Q:What's the difference between the three eccentric butterfly valve and the two eccentric butterfly valve?
Single eccentric butterfly valve: extrusion problems, address concentric butterfly valve and valve seat of the resulting in a single eccentric butterfly valve, the structural characteristics of the stem axis deviated from the disc center, so that the butterfly is no longer a rotary bottom plate, axial dispersion, reduce the excessive squeezing and the lower end of the seat of the butterfly board. Double eccentric butterfly valve: in the single eccentric butterfly valve on the basis of further improvement of forming, is the most widely used double eccentric butterfly valve.
Q:Is the pressure test of the centerline butterfly valve checked or checked?
Every factory factory must require pressure tests.
Q:What type of butterfly valves do you have in DN125?
125D42X: manual double eccentric flange butterfly valve 125D3 (6, 9) 42X: worm (gas, electricity) double eccentric flange butterfly valve125D41X: manual single eccentric flange butterfly valve 125D3 (6, 9) 41X: worm (gas, electricity) moving single eccentric flange butterfly valve125D43H: manual three eccentric flange butterfly valve (hard seal)125D3 (6, 9) 43H: worm (gas, electricity) move three eccentric flange butterfly valve (hard seal)125D71X manual alignment type butterfly valve125D3 (6, 9) 71X worm (gas, electricity) midline type clip butterfly valve125D3 (6, 9) 73H, worm (gas, electricity) three eccentric pair clip butterfly valve (hard seal)125BD71 (F4) X corrosion resisting fluorine (wrapped) pair clip butterfly valve

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches