Fire Fighting Truck Light Truck 2000L~5000L
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 PCS
- Supply Capability:
- 1000 PCS/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Fire Fighting Truck Light Truck 2000L~5000L
Basic Info.
Model NO.:LLX5103GXFSG40L
Type:Tanker
Certification:ISO9000
Volume:3001-5000L
Emission Standard:Euro 3
Transmission Type:Manual
Engine Type:4 Stroke
Payload:10000kg
Fuel:Diesel
Drive Wheel:4×2
Horsepower:150-250hp
Condition:New
Model of Chassis:Isuzu 700p - Ql1100tlary
Model of Engine:4kh1-Tc
Cab Capacity:6 Person(Including Driver)
Export Markets:South America, Southeast Asia, Africa, Mid East, Eastern Asia
Additional Info.
Trademark:Isuzu
Packing:Packed in Nude
Standard:ISO
Origin:Linyi, Shandong, China
HS Code:8705309000
Product Description
The fire engine has strong power, high speed, large carrier liquid volume and other characteristics; with using extended cab, ride comfort, operational focus, easy maintenance, and can be widely used in cities public security petrochemical, industrial enterprises and ports, terminals and other places, a large oil fire fighting and general material fire, is an ideal large fire equipment.
Fire Fighting Truck Light Truck 2000L~5000L | |||||
No. | Model | Driving type | Cab | ||
1 | LLX5103GXFSG40L | LHD | Double Cab | ||
Chassis Model | QL1100TLARY | Gross Weight | 10000KG | ||
Engine | Brand Isuzu | Transmission | MLD-6Q | ||
4HK1-TC EURO 3 | Maximum Output | 175HP | |||
Power Takeoff | FVR34QJ/700P | Max. Torgue | 500Nm/(1500-2000)rpm | ||
Rated engine power | 129Kw/2600rpm | Overall Dimension(mm) | 6860*2200*2910 | ||
Tank volume (L) | 4000(SG40L) | Displacement | 5.193L | ||
Wheel base ( mm ) | 4175 | Max.Driving Speed( km/h) | 95 | ||
Fire pump | Model | CB10/30 | |||
Flow | 30L/s | ||||
Pressure | 1MPa | ||||
Fire monitor | Model | PS30-50D | |||
Flow | 30 L/s(1.0Mpa) | ||||
Throw range | ≥50m |
- Q:What is an annular fire lane?
- 6.0.2 has a closed courtyard or patio buildings, while the short side length is greater than 24.0m, the fire lane should be set to the inner courtyard or patio.6.0.3 has a closed courtyard or patio buildings along the street, should be pedestrian streets and communicated inner courtyard (use staircase), the distance should be less than 80.0m.
- Q:What's this part of the fire engine for?
- This is a telescopic ladder. It's folded and shrunk,Inside the transmission mechanism, also had the kind of beautiful, naked ladder!
- Q:Which of the latest fire laws is blocking the safe passage?
- Twenty-eighth of any unit or individual shall not damage, misappropriation or unauthorized removal, stop using fire control facilities and devices, and shall not bury, occupy or cover a fire hydrant or occupy fire prevention space, shall not be occupied, clogging evacuation routes closed, safety exit, fire channel. Doors and windows in crowded places shall not be equipped with obstructions that affect escape, fire and rescue.
- Q:Would like to ask the fire engine turning radius requirements, I checked the "building design fire code", only written "return field" area, did not write the fire engine turning radius requirements. Specific can be found in which norms?
- You can determine the minimum turning radius of the roadway fire is not less than 12 meters (the inside wheel). As for fire engines, there are also differences in wheelbase sizes
- Q:What is the minimum turning radius of fire lane?
- (3) the end fire lane should be set back lanes or enter the field, enter the area should not be less than 12mX12m, for the high-rise buildings, not less than 15mX15m; for large fire engines use enter area of not less than 18 * 18 square meters.(4) the fire lane pipe and drain should be able to withstand the pressure of large fire truck.
- Q:What is the width of the fire engine body?
- The longest length is not more than 10 meters wide, the width is not more than 3 meters, the highest height is not more than 3.5 meters.The maximum length of special fire engines is 13.4m, the maximum width is 4.5m, and the maximum height is 4.15M
- Q:What equipment does the fire engine have?
- Fire button (start fire water pump), and some are also equipped with emergency lights, fire reels, etc., as well as double hydrant hydrant box, inside the plug mouth, hose, water gun are two groups
- Q:Is the minimum width of fire passage for public buildings 4.0m or 6.0m?
- Fire lane settings should be comprehensive, the road load is too small, the road below the pipe is too shallow, and the ditch used light cover plate, etc., can not withstand the passage of large fire engines. In addition, as can be seen from the table, due to the large fire truck body length and minimum turning diameter is too large, therefore, enter the field set the fire lane for 12 * 12m was impassable, enter the field to set a larger area to meet the use requirements, it shall be determined according to the local actual equipped with large fire engines.
- Q:Fire engine fire pump pressure is low, what's the matter?
- Now the pump power is only 85.95KW, pump the water from the water surface to enhance the height of 200m, although 86KW a lot higher than that of the 69KW power, but with the increase of mechanical lift, efficiency will be reduced, the head loss will increase, the amount of water it will not be able to power and lift the proportion, can only reach 20L/S. According to the law of conservation of function, that is, regardless of the mechanical efficiency and head loss, the water discharge at the height of 200m should reach 40L/S. At the very least 140kW power, 86KW, of course, is far from, so the traffic is small.
- Q:Deliberately not fire engines, how to punish?
- If a fire truck is deliberately avoided, or if it prevents him from performing an urgent task, he may be fined two hundred yuan or less, and if the circumstances are serious, he may be detained for not less than five days but not more than ten days, and may also be fined not less than five hundred yuan.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Fire Fighting Truck Light Truck 2000L~5000L
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 PCS
- Supply Capability:
- 1000 PCS/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Related keywords