• Electric Submersible Pump (ESP) Using in Oilfield System 1
  • Electric Submersible Pump (ESP) Using in Oilfield System 2
  • Electric Submersible Pump (ESP) Using in Oilfield System 3
Electric Submersible Pump (ESP) Using in Oilfield

Electric Submersible Pump (ESP) Using in Oilfield

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
50 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1. Structure of Electric Submersible Pump (ESP) Description


Electric Submersible Pump (ESP) is a new oil extraction equipment. It has had a series of products, can not only be used in low-viscosity crude oil extraction, but also applicable to the extraction of heavy oil, high freezing point oil, high wax oil, high sand-containing oil and high gas-containing oil, with the superiority irreplaceable by other screw oil equipments. 

Advantage:

1)Suitable for sucking high viscosity fluid and solids-laden fluid.
2)Hardly gas locking, breakdown of emulsion.
3)The pumping process is continuous and stable .
4)Suitable for vertical,deviating,horizontal well, specially suitable for the well which has the sucker rod scrubbed the tube.
5)No sucker rod, which could eliminate the loss caused by the scrubbing of the tube.
6)Save energy compared with the sucker rod pump.


2. Main Features of Electric Submersible Pump (ESP)


1)Suitable for vertical,deviating,horizontal well 
2)Non-sucker -rod 4. save energy

3) Good price and service


3. Electric Submersible Pump (ESP) Images


Electric Submersible Pump (ESP) Using in Oilfield

Electric Submersible Pump (ESP) Using in Oilfield

Electric Submersible Pump (ESP) Using in Oilfield


4. Electric Submersible Pump (ESP) Specification


Electric Submersible Pump (ESP) Using in Oilfield


5. FAQ of Electric Submersible Pump (ESP)


We have organized several common questions for our clients,may help you sincerely:


①How about your company?

One of the leading manufacturers and suppliers in China, mainly offering various of oilfield products consists of our one-stop sales. The integrated sales & service ensures customers with various demands an easier access for purchasing management.


②How to guarantee the quality of the products?

We have established the international advanced quality management system,every link from raw material to final product we have strict quality test;We resolutely put an end to unqualified products flowing into the market. At the same time, we will provide necessary follow-up service assurance.


③How long can we receive the product after purchase?

In the purchase of product within three working days, We will arrange the factory delivery as soon as possible.

Q:Double floor sewage pump circuit diagram of a small problem
Question 3 when the water level is low, when the 1KA is connected, the pump will run depending on where your SS selector switch is located. Its left and right position, running pump and standby pump definition is different, left position is 1#, running 2# standby, right position is 2# running, 1# standby. Only inIn case the high level switch 2KA is connected, the standby pump may work at the same time.
Q:If the calculation of the required pump flow is 45, lift 110, and the actual pump flow 100, head 125, what will happen in operation? Can I use it properly?
Centrifugal pumps are too big to measure.There is a reason why the centrifugal pump does not measure up:The pump inlet pipe blockage, leakage.The pump inlet pressure is too low.
Q:How many concrete pump tube diameter
High pressure is the outer diameter is Phi 140 Type 150 type low pressure pipeline; pipe diameter is Phi 159 pipeline, high pressure pipeline diameter is phi 168.
Q:How to calculate the motor power of metering pump?
Two Hydraulic power, metering pump rated flow (L/H) X, maximum pressure (Barg) / 36000 = kw
Q:What are the uses and precautions of magnetic pumps?
Notice of use:1. prevent particles from enteringHas the ferromagnetic impurities and particles into the magnetic actuator and bearing friction is not allowed.The transport of crystallization or precipitation of the medium to the flushing (after pumping water, poured into the pump cavity drained after running 1min), in order to ensure the service life of bearing.The transport medium containing solid particles, the pump flow tube inlet filter.
Q:How many pumps does the 80cm tank use?
For example, you are 80 cm tank, assuming you are 40 cm wide, the water surface is also 40 cm, then the final count by 80X40X40=128000 cubic centimeter, that is, 128000 ml.
Q:Please give me professionals to calculate, the cylinder bore is 100 and the rate of 20m/s, the leakage can be ignored, but to the large flow pump!
3. efficiencyVolume efficiency, for hydraulic pumps, is the ratio of actual flow to theoretical flow. A hydraulic motor is the ratio of its theoretical flow to its actual flow.Mechanical efficiency, for hydraulic pumps, refers to the ratio of theoretical torque to actual input torque. The actual output torque of the hydraulic motor is theoretical torque to overcome the torque after friction, so the mechanical efficiency is the ratio of the actual output torque to the theoretical torque.
Q:What is the name of the day pump and ground pump? Specific introduction
PumpGround pumps are used very frequently in many large basements, because they have no boom, so they need to be taken over manually. In addition to the site, for those days to pump the high-rise buildings, such as 200 meters or 200 meters altitude, can also take over to transport concrete by pump, but the premise is to have enough power to pump concrete will hit above the height and the length of nozzle can reach the height of the floor.Thus, the day pump and ground pump have their respective advantages. The pump is easy to use, but the ground pump can make up for the height that the pump can not reach. At the same time, the price is relatively cheap, so users can choose the corresponding concrete pump when they are in use.
Q:No negative pressure water supply equipment, both the main pump and auxiliary pump, power is not the same, how to choose the control cabinet?
Non negative pressure water supply equipment can be divided into non negative pressure tank and box type non negative pressure compensation device, steady flow tank type non negative pressure water supply equipment is the negative pressure tank, pressure tank can eliminate the negative effect of network equipment, is equipped with a vacuum suppressor and water protection box; non negative pressure water supply equipment has the advantages of simple device is a water tank with the boost voltage stabilizing device of complex box at the same time with no negative pressure tank.The tank type non negative pressure water supply equipment adopts vertical multistage centrifugal pump. This kind of pump is low noise and high efficiency. Such as CDL series and imported CR seriesOrdinary box type non negative pressure water supply equipment can use multi-stage centrifugal pump, also can use stainless steel submersible pump, submersible pump costs will be lower, but the maintenance costs will be high.
Q:What are the problems that should be paid attention to when using vacuum pumps?
What are the problems that should be paid attention to when using vacuum pumps?

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords