Reinforcing concrete welded mesh with high quality
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 9 m.t.
- Supply Capability:
- 100 m.t./month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Quick Details
Place of Origin: Tianjin, China (Mainland)
Material: Black Wire Mesh
Type: Reinforced Mesh
Application: Woven Wire Mesh
Weave Style: Plain Weave
Wire Diameter: 3-12m
Technique: Welded Mesh
Model Number: welded mesh
Brand Name: AGY
Wire diameter: 3mm to 12mm
Line wire spacing: min100 mm. larger line wire spacing in steps of 50 mm
Cross wire spacing: min 25mm. above programmable in increments of 0.1 mm.
Wire mesh length: 500- 12000 mm
Wire mesh width: 500- 3300 mm
Packaging & Delivery
Packaging Details: | Reinforcement Concrete Welded Wire Mesh Black Sheet Standard export package(with pallet) or as per customers' request |
---|---|
Delivery Detail: | Within 7 days |
Product Description
Introduction to welding mesh
Welded steel wire mesh made from low carbon steel wire rods, which undergo a cold-rolling and straightening process,and then arranged vertically in proper spacing in the welding equipment both at line wires and at cross wires ,and joint together by mean of electric resistance spot-welding(also directly welded with hot-rolled wire rods ), turning into steel fabric mesh sheets.
STANDARD | Rm TENSILE STRENGTH Mpa/(ksi) | ELONGATION (Reduction of area) | SHEAR STRENGTH (N/mm2) | BEND TEST | |
ASTM Standard Specification for Steelwire/Steel Welded Wire Reinforcement,Plain,for Concrete | ASTM A 82M-07 | ≥550(80) | (Z≥30%) | - | D=2d |
ASTM A185M-06 ≥φ3.15mm | ≥515(75) | (Z≥30%) | ≥241xSmax | D=2d | |
BS 4482:2005 Steel Wire for the Reinforcement of Concrete | 500<8mm< td=""> | ≥510 | Agt≥1.0% | - | D=4d |
500 ≥8mm | ≥525 | Agt≥2.5% | |||
BS 4483:2005 | B500A | ≤650 | Agt≥2.5 (ifd<8mm,≥1.0)< td=""> | ≥125xSmax | D=4d |
B500B | ≤650 | Agt≥4.0% | |||
B500C | ≤650 | Agt≥6.0% | |||
BS 4449:2005 Steel for the Reinforcement of Concrete-Weldable Reinforcing Stee | B500A | ≤650 | Agt≥2.5% (ifd<8mm,≥1.0)< td=""> | ≥121xSmax | if d≤16(D=4d) if d>16(D=7d) |
B500B | ≤650 | Agt≥5.0% | |||
B500C | ≤650 | Agt≥7.5% | |||
AS/NZS 4671:2001 Steel Reinforcing Materials | 500L | ≤750 | Agt≥1.5% | ≥250xSmax | D=4d |
500N | ≤650 | Agt≥5.0% | |||
500E | ≤600 | Agt≥10.0% | |||
SS 561:2010 | 500A | ≤650 | Agt≥2% | ≥250xSmax | D=4d |
500B | ≤650 | Agt≥4.0% | |||
500C | ≤650 | Agt≥6.0% |
Square Mesh AS/NZS 4671- Class L | |||||
Product Code | Std Unit | Longitudinal Wires | Cross Wires | Mass(kg) | Dimensions(m) |
SL52 | sheet | 10×4.77@200+4×4@100 | 30×4.77@200 | 21 | 6×2.4 |
SL62 | sheet | 10×6@200+4×4.77@100 | 30×6@200 | 33 | 6×2.4 |
SL72 | sheet | 10×6.75@200+4×4@100 | 30×6.75@200 | 41 | 6×2.4 |
SL81 | sheet | 25×7.6@100 | 60×7.6@200 | 105 | 6×2.4 |
SL82 | sheet | 10×7.6@200+4×5.37@100 | 30×7.6@200 | 52 | 6×2.4 |
SL92 | sheet | 10×8.6@200+4×6@100 | 30×8.6@200 | 66 | 6×2.4 |
SL102 | sheet | 10×9.5@200+4×6.75@100 | 30×9.5@200 | 80 | 6×2.4 |
×Diameter (mm) × Spacing (mm) |
Rectangular Mesh AS/NZS 4671 - Class L | |||||
Product Code | Std Unit | Longitudinal Wires | Cross Wires | Mass(kg) | Dimensions(m) |
RL718 | sheet | 25×6.75@100 | 30×7.6@200 | 67 | 6×2.4 |
RL818 | sheet | 25×7.6@100 | 30×7.6@200 | 79 | 6×2.4 |
RL918 | sheet | 25×8.6@100 | 30×7.6@200 | 93 | 6×2.4 |
RL1018 | sheet | 25×9.5@100 | 30×7.6@200 | 109 | 6×2.4 |
RL1118 | sheet | 25×10.7@100 | 30×7.6@200 | 130 | 6×2.4 |
RL1218 | sheet | 25×11.9@100 | 30×7.6@200 | 157 | 6×2.4 |
AGY can produce not only the mesh according to the national standard of Welded steel fabric for the reinforcement of concrete(GB/T1499.3-2010) but also the products compliance with the AS/NZS 4671:2001 (Australian and New Zealand standard), BS4483 (English standard), DIN488 (Germany standard), SIA 16211 S 550(Switzerland standard) and NFA35-016 (France standard) etc.
- Q:True or False?Branch wiring from a 200A - 3 phase 4 wire panelboard.WIRE #PHASES 1 --- PHASE A 2 --- PHASE B 3 --- PHASE C 4 --- NEUTRAL - WHITE WIRE 5 --- PHASE A 6 --- PHASE B 7 --- PHASE C 8 --- NEUTRAL 9 --- GROUNDTOTAL OF 9 WIRES GOING TO SIX (6) 20A 120V CIRCUITS
- Wrong. The panel has the set up so that a 3 phase breaker can be next to each other for example Breakers left side of panel 1= #1 line 3= # 2 line 5 = #3 line Neutral is the large bar on the side were the ground line goes. don't attach a neutral line to a breaker!!!!!! Make sure you buy a 3 phase breaker for equipment with that voltage and phase.
- Q:just need how u think it would be wired for like the whole circuite thingy
- for battery charlieC for house supply put the switch in the live wire and not on the neutral.
- Q:Im wondering if this 24 awg wire is good for guitar wiring. Doesn't look like something that i usually would see people use when wiring, since there is lots of different wires and colour coding wrapped up inside it.
- Given okorder / I hope this will help with your decision. Good luck!
- Q:What is a tubeless wire and how does it work?
- It is a wire without a tube. It works properly, it has a larger section than the usual wires, but is cheaper (Al is cheaper than Cu).
- Q:I need to get to the audio wiring
- you cannot simply go with matching the colors factory radios have extra wires that are not needed with an aftermarket install most of the time (wires that control the dimmer on the radio, speed sensitive volume) you will need three power wires (constant, ignition, and ground), plus your speaker wires use a test light to test your wires, usually at the radio the yellow wire is your constant, the red is your ignition, and black is always ground to find your constant use the test light, it will be hot at all times so that your radio can remember the time, and your settings- next you need your ignition, it is only hot when the key is on or in the accessory position, to tell the radio when to come on- the ground is self explanatory to find which wires go to what speakers all you need is a 9v battery, put the positive end to a wire and test all of the other wires to the negative side and you will hear a crackling noise from a speaker when you have the right combination
- Q:wiring kit, subwoofers
- by wiring kit do you mean the amps power kit? some of which will include speaker wire for the subs anyway usually your amp will come with instructions that tell you what the minimum gauge is the amp will accept for power, this is the gauge power and ground cable you will want to get maximum power to the amp and to prevent overheating issues, typically amps under 400 watts rms power will do fine with 8 gauge, amps 400-1000 rms will use 4 gauge and 1000+ will use 2/0 gauge wire, for the subwoofer speaker wire you can never go too big gauge only too small, a kicker 12 gauge speaker wire will work for almost any application
- Q:I'm replacing the door speakers in a 2001 Coupe Camaro with the factory sound system. I needed to know which wire was positive and which was negative so I bought a circuit tester. However, I keep getting the reading that both wires are positive. What could be causing this? I know the circuit tester works because I tested it on the battery terminals and it worked fine.
- You cannot use a circuit tester on speaker wires. It is not the correct tester. All you have to do is look at factory speaker it's marked positive and negative.
- Q:The 1992 camry wiring diagram comes up to about 19 wires, my stock stereo that I unplugged from the back on the harness has about 14, and it has 3 black wires 2 brow, 2 green and 2 red, the others only have one wire, why is this?
- Each okorder /... That site should bring you some clarity.
- Q:I'm doin this thing where I need to connect some wires and one part uses Apple iPod headphones. Inside those wires, they have insulation. I burnt the wires so the insulation would not be in the way. Will the wires still conduct the electricity? Or will I just need to find some other headphones without insulation to do this with?
- The undertaking of the conductors interior the cable won't regulate, however the insulation would burn and allow the conductors to the touch, making a short circuit. this could circumvent the I Pod working and would harm the output amplifier.
- Q:Someone Stole my stock radio out of my car (They cut it out) Now All i have in the is wires and I cannot afford to go get a new one installed.Here are the wires that are in my car
- Here's your audio wiring layout: Car Radio Battery Constant 12v+ Wire: Yellow/Green Car Radio Accessory Switched 12v+ Wire: Orange/Green Car Radio Ground Wire: Black/Green Car Radio Illumination Wire: Orange/Black Left Front Speaker Positive Wire (+): White/Black Left Front Speaker Negative Wire (-): Gray/Black Right Front Speaker Positive Wire (+): White/Red Right Front Speaker Negative Wire (-): Gray/Red Left Rear Speaker Positive Wire (+): White/Green Left Rear Speaker Negative Wire (-): Gray/White Right Rear Speaker Positive Wire (+): White Right Rear Speaker Negative Wire (-): Gray
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Reinforcing concrete welded mesh with high quality
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 9 m.t.
- Supply Capability:
- 100 m.t./month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Related keywords