• Boiler Feed Centrifugal Multistage Water Pump System 1
  • Boiler Feed Centrifugal Multistage Water Pump System 2
  • Boiler Feed Centrifugal Multistage Water Pump System 3
Boiler Feed Centrifugal Multistage Water Pump

Boiler Feed Centrifugal Multistage Water Pump

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
100000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

                    Boiler Feed Centrifugal Multistage Water Pump

1.Structure of  Boiler Feed Centrifugal Multistage Water Pump Description

 

Boiler Feed Centrifugal Multistage Water Pumpis used for transporting pure water (particles density shall be max.1%by volumeand granular size shall be max 0.1mm in dimeter) of the liquids with physical and chemical properties similar to pure water. Type MD pump is applied with wear resist material, especially suitable for mineral drainage. The particles density shall be max. 1.5% (Max. of the granular diameter is 0.5 mm).The liquid temperature ofD, MD pumps shall be lower than 80°C.

 

2.Main Features of the Boiler Feed Centrifugal Multistage Water Pump

• Compact structure, good appearance, low construction

Operation stably, same inlet and outlet

•Convenient installation and maintenance

Customized design is available, OEM and ODM are welcomed.

•Horizontally and vertically installation as different pipeline system

3. Boiler Feed Centrifugal Multistage Water Pump images

Boiler Feed Centrifugal Multistage Water Pump

4. Boiler Feed Centrifugal Multistage Water Pump Specification

 

Item

Multistage Pump

Multistage Pump

Horizontal Multistage Pump For Pure Water

Model

CMD

Material

Cast iron,Stainless steel

Mode

Horizontal

Color

Blue

Temperature

<=80°c< span="">

Seal

packing seal

Theory

Centrifugal Pump

Structure

Multistage Pump

Usage

Water

Power

Electric

Standard or Nonstandard

Standard

Fuel

Diesel

Pressure

High Pressure

Application

Hot and cold pure water

Outlet Diameter

40-500mm

Capacity

6-1250 m3/h

Head

75-1800m

Rotation Speed

1450-2950r/min

Power

5.5-2400kW

Certificate

ISO9001

Feature

High efficiency,Easy maintenance 

 

5.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.

 

Q:What's the difference between a centrifugal pump and a centrifugal pump? What are they used for?
Centrifuges are generally used to classify liquids of different densities in liquids.
Q:Water pump spoon pipe for power plantWhich hero can tell me what is the water pump spoon tube ah? And its role
Then control the speed level, to achieve the purpose of regulating the speed and flow of the feed water pump.
Q:Concrete pump 125 pipe wall thickness
Concrete pump, also called concrete pump, consists of pump body and pipe. The utility model relates to a machine for continuously conveying concrete along a pipeline by utilizing pressure, which is mainly used for building, bridges and tunnels
Q:Troubleshooting of diaphragm pump
In the application of the pump, these conditions are likely to encounter. Each situation can be divided into several possible reasons. This guide lists the causes of failures and gives appropriate corrective maintenance measures. The meaning of all the specific terms in the guide is listed later.Air valves - copper or stainless steel valves are bolted to the center of the pump by four bolts.The piston aluminum cylinder is enclosed in the air valve to control the gas flow.Cavitation - because the pump inlet for the amount of fluid to reduce or lack, the pump discharge is less than the amount of quantitative. In fact, the fluid chamber is full of fluid before it is discharged.Static pressure drop - the inlet pressure from the pump centerline to the free point - the inlet is measured in pounds, including the specific gravity and velocity of the fluid.
Q:Does the reservoir water heater press the booster pump (high marks)?
In addition, the water storage electric water heater has a safety valve is O.7MPa, before buying a booster pump, you can check the water inlet valve spring weakness, see the effect of water, barely even, then use it, do not buy.
Q:Why adjust the centrifugal pump outlet valve can adjust the flow? What are the advantages and disadvantages of this method? Is there any other way to regulate the flow of the pump?
The use of frequency converter to adjust the speed of the motor can also adjust the flow, the advantage is to save electricity.
Q:No negative pressure water supply equipment, both the main pump and auxiliary pump, power is not the same, how to choose the control cabinet?
Non negative pressure water supply equipment can be divided into non negative pressure tank and box type non negative pressure compensation device, steady flow tank type non negative pressure water supply equipment is the negative pressure tank, pressure tank can eliminate the negative effect of network equipment, is equipped with a vacuum suppressor and water protection box; non negative pressure water supply equipment has the advantages of simple device is a water tank with the boost voltage stabilizing device of complex box at the same time with no negative pressure tank.The tank type non negative pressure water supply equipment adopts vertical multistage centrifugal pump. This kind of pump is low noise and high efficiency. Such as CDL series and imported CR seriesOrdinary box type non negative pressure water supply equipment can use multi-stage centrifugal pump, also can use stainless steel submersible pump, submersible pump costs will be lower, but the maintenance costs will be high.
Q:Types and differences of pumps
Classification and working principle of pump by structureClassification of pumpsInvolved pump standard product types are also very much, a centrifugal pump, metering pump, screw pump, reciprocating pump, hydraulic pump, submersible pump, oil pump, water pump, pressure test pump, vortex pump, cryogenic pump, vacuum pump, roots pump, molecular pump, gear pump, mud pump, corrosion-resistant pump deep well pump, water pump, mixed flow pump, axial flow pump, boiler feedwater pump, liquid pump, injection pump, chemical pump, pump plugging and no leakage pump, plastic pump, fire pump and so on, there are many. Its name is divided according to some conventional classification methods such as pump vane pump volume, pump etc., some are divided by purpose such as sewage pump, pump and other health, some names are more random as diffusion pump, liquid nitrogen pump. As long as the production of this product, with standard requirements, through a certain application and approval procedures may produce a new The standard, but sometimes the content also has a repeated cross, quite. The domestic and foreign standards, the domestic standard is more than the number of foreign standards. In general, such as centrifugal pumps are widely used, the production history of the pump more standard (total standard centrifugal pump up to more than 100). As new standard pump leakage pump this rapid development is relatively small. This paper introduces the structure and working principle of the pump according to the classification of the
Q:Direct connection pump What is straight pump and non direct pump? What's the difference in structure?
What is straight pump and non direct pump? Direct coupled pump shaft and the motor shaft is directly coupled with the coupling and non direct coupled pump: pump shaft and motor shaft through the belt pulley, V-belt connection or other forms of transmission. What is the difference in the structure: the direct coupled pump has the advantages of compact structure, simple installation, but the relatively small power; non direct coupled pump: pump and motor is independent, the two transfer torque through the belt, the structure is relatively large, complex installation, general power is relatively large.
Q:How accurate is the metering pump?
Three automatic compensation valve device widely used in diaphragm metering pump, especially with suction height requirements, can only be used by three separate Fujian (safety valve, discharge valve and oil supply valve) compensation device.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords