• HV Electric Power Cables Different Types of Electrical Cables for Copper System 1
  • HV Electric Power Cables Different Types of Electrical Cables for Copper System 2
  • HV Electric Power Cables Different Types of Electrical Cables for Copper System 3
  • HV Electric Power Cables Different Types of Electrical Cables for Copper System 4
  • HV Electric Power Cables Different Types of Electrical Cables for Copper System 5
  • HV Electric Power Cables Different Types of Electrical Cables for Copper System 6
  • HV Electric Power Cables Different Types of Electrical Cables for Copper System 7
  • HV Electric Power Cables Different Types of Electrical Cables for Copper System 8
HV Electric Power Cables Different Types of Electrical Cables for Copper

HV Electric Power Cables Different Types of Electrical Cables for Copper

Ref Price:
get latest price
Loading Port:
China main port
Payment Terms:
TT or LC
Min Order Qty:
1000 m
Supply Capability:
20000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specification

Different types of electrical cables
1.IEC standard Made in China
2. factory price distributor
3, 12 years produce experience

HV/MV/LV PVC/ XLPE/ Copper/aluminum

Armoured/unarmored electric power cables

Different types of electrical cables

 

  Main Electrical Characteristics

   

Type

 

Name

 

Suitable areas

 

Copper-conductor

 

AL-conductor

YJV

YJLV

XLPE-insulated cable sheathed with PVC

Indoor, tunnel, cable channel

YJY

YJLY

XLPE-insulated cable sheathed with polythene

YJV22

YJLV22

XLPE-insulated cable sheathed with PVC and armored with steel tape

Direct burial in the ground and the capacity of bearing certain mechanical force, not proper in the pipeline

YJV23

YJLV23

XLPE-insulated cable sheathed with polythene and armored with steel tape

YJV32

YJLV32

XLPE-insulated cable sheathed with PVC and armored with thin steel wire

The bed of river and shallow sea, as the link line between the two platforms of oil and gas station in the water, the capacity of bearing tensile force.

YJV33

YJLV33

XLPE-insulated cable sheathed with polythene and armored with thin steel wire

YJV42

YJLV42

 

XLPE-insulated cable sheathed with PVC and armored with thick steel wire

YJV43

YJLV43

 

XLPE-insulated cable sheathed with polythene and armored with thick steel wire

 Main Features

Conductor

Compact Stranded Copper Conductor, Class 2 as per IEC 60228

Circular solid Copper Conductor, Class 1 as per IEC 60228

Flexible Stranded Copper Conductor, Class 5 as per IEC 60228

Conductor Screen

Semi-conductor (MV only)

Insulation

XLPE(Cross-linked polyethylene)

Insulation Screen 

Semi-conductor (MV only)

Separate Screen 

Copper Tape (MV must, LV optional)

Filler

PP Yarn, or Paper

Wrapping Tape

PP

Inner Covering

Extruded PVC (MV only)

Armour

Steel Wire, or Steel Tape, or Aluminium Tape or unarmored

Overall Sheath

PVC or PE

 Picture

 

 

Q:The difference between power cable and overhead cable
. the power cable occupies less. Generally buried in the soil or laying in the room, the channel, the tunnel, the line between the insulation distance is small, no tower, covers an area, basically does not occupy the ground space. The overhead cable is the opposite. . power cable reliability. Affected by climatic conditions and the surrounding environment, transmission performance is stable, high reliability. . the power cable has to ultra-high pressure, large capacity development of more favorable conditions, such as low temperature, superconducting power cables. . the power cable distribution capacitor larger. Overhead cable is the opposite . the power cable maintenance work less overhead cable is the opposite . the power cable electric shock is unlikely. The overhead cable is the opposite
Q:When doing competition, is there a rule where your battery in the back can't be bigger than the one in the front? Are Monster Cables as good as they perceive to be???? I.E. their 400 series cables that are wound in different arrays to optimize each frequency out put? Can a Power cable actually provide more efficiency if constructed right, once again, their 400 series?Subwoofers being 1000 RMS but only getting 500, will running them at their RMS make a significant difference?
I'm not 100% sure but I think that doesnt matter. What matters is the amount of batteries you have. There is a significant difference between 500 to 1000 watts. But it depends on what enclosure is being used that makes it louder...much louder in some cases.
Q:for any SATA 2 HDD, the power connector is longer. compared to the data transfer cable. wht is it so?,-------------- ,------the first set of lines represent the power connector second; the data connection cable.
The sata power connector provides 3.3, 5v and 12v as well as two ground connections (in between the 3.3 and 5 and 5 and 12) I believe. Anyway, for the power connectors, a single pin has a maximum rating of 1.5A or so, and so they provide three pins if a device needs needs more current.
Q:I am installing a sound system in my car straight from scratch. I have built the subwoofer enclosure but now I have run into a problem. The existing amplifier power cable is too short to reach my amp. I was wondering if any other cable could be used as a substitute to extend it just a few more inches or do I need to buy a whole new amp kit? Thanks
Splices are not wise when high current is passed. It's a perfect spot for overheating. However, using a distrobution block as a splice would work fine. It won't look pretty but you can cut up a set of jumper cables as long as they're the same guage. Of course the more strands in stranded wire, the better.
Q:I have lost the power cable which came with my computer's PSU and after looking online for a while the online shops seem to sell the power cables with little information about whether or not they will function with different PSUs so I am guessing it doesn't matter which one I buy.
They are not special just a kettle lead really and should cost less than $5 as said if it fit it is good, look around you probably have one lying around
Q:I just bought it!
It's obviously faulty. You really should only hear the power brick fan if you put your ear up to it.
Q:I bought this printer recently, and it only came with a USB cable, and when i plug it into my computer, it won't turn on. Is there a power cable that's supposed to come with it?
Yes, okorder using the Service Tag on the printer. Call them, email them, or chat over the internet with their tech support.
Q:im running 4 ga power cable through my 2003 civic and im wondering if anyone hase any good places to run it through?
I have a 2003 Civic EX and simply created a hole in the boot that has some large cable going through it right below the Glove box. I have no leaks I too have 4 ga size wire. Good luck.
Q:I'm installing aftermarket amp and subwoofers in the trunk. I currently as a temporary fix ran the cable outside and in through the passenger door on the car, then under the carpet to the trunk. Is there a break in the firewall anywhere that I can put it through instead? Thanks for your help!
examine first if there are the different wires that have been given burned apart from the distant twine and the flexibility cable. examine additionally your fuse if that's nevertheless ok. confident, you ought to purchase those wires from a ironmongery shop or an digital keep via ft or via backyard.. For the flexibility cable use gauge 8 or gauge 4 wires, for the distant twine use gauge sixteen or 14. until now setting up the wires be sure to ascertain your amp and your stereo if there are nevertheless working because of the fact short circuit on power cable often ends up in broken the audio factors interior the amp or the vehicle stereo or the two. be sure to double examine all connections and conenct the fuse of the flexibility cable final to circumvent short circuiting
Q:I have a Maxtor 3200 and I accidentally plug in the wrong power cable for it. I saw the light flicker on then off. I realized my mistake and tried to plug it in its correct cable but now it won't turn on at all. I figure that the wrong cable must of forced too much energy through it. I have a lot of important files on there. I know that fixing it won't be cheap, I fully realize that. However, is there any hope of retrieving my files at all?
Without knowing more, I can give you a definite answer. However, you do have a chance of getting your files back, especially if it's just the enclosure that's fried. In that case, it's a no brainer to yank the drive, and either toss it on a converter cable, or directly in a system. Have you looked to see how hard it is to take apart the enclosure?

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords