• EPR   Fire   Resistant   Marine   Cable System 1
  • EPR   Fire   Resistant   Marine   Cable System 2
EPR   Fire   Resistant   Marine   Cable

EPR Fire Resistant Marine Cable

Ref Price:
get latest price
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
1000 m
Supply Capability:
20000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Marine Cable

EPR Fire resistant Marine Cable application

This cable is used on ships,petrol platforms and offshore buildings for emergency power,light and control system.

EPR Fire resistant Marine Cable standards

IEC 60092-350
IEC 60092-353
IEC 60332-1-2
IEC 60332-3-22
IEC 67054-1-2
IEC 61034

EPR Fire resistant Marine Cable service condition

1.Rated Voltage:0.6/1(1.2)kV,1.8/3 kV

2.Long term allowable working temperature:90°C

3.Finished Cable can withstand AC 3.5kv/5 minutes without puncture.

4.Cable bending radius

Cable StructureCable Outer DiameterMinimum Bending Radius
Metal Braided Armored6D
Non ArmoredD≤254D
D>256D

EPR Fire resistant Marine Cable Model

ModelCombustionName
CEPFSC/NC/NSCEPR insulated LSZH SHF1 sheath flame retardant marine power cable
CEPF80SC/NC/NSC

EPR insulated LSZH SHF1 inner sheath bare copper wire braid armored flame retardant marine power cable

CEPF85SC/NC/NSCEPR insulated LSZH SHF1 inner sheath bare copper wire braid armored SHF1 outer sheath flame retardant marine power cable
CEPF90SC/NC/NSCEPR insulated LSZH SHF1 inner sheath bare steel wire braid armored flame retardant marine power cable
CEPF95SC/NC/NSCEPR insulated LSZH SHF1 inner sheath bare steel wire braid armored SHF1 outer sheath flame retardant marine power cable
CEPFRSC/NC/NSCEPR insulated LSZH SHF1 sheath flame retardant marine power flexible cable
CEPJSC/NC/NSCEPR insulated LSZH SHF2 sheath flame retardant marine power cable
CEPJ80SC/NC/NSCEPR insulated LSZH SHF2 inner sheath bare copper wire braid armored flame retardant marine power cable
CEPJ85SC/NC/NSCEPR insulated LSZH SHF2 inner sheath bare copper wire braid armored SHF1 outer sheath flame retardant marine power cable
CEPJ90SC/NC/NSCEPR insulated LSZH SHF2 inner sheath bare steel wire braid armored flame retardant marine power cable
CEPJ95SC/NC/NSCEPR insulated LSZH SHF2 inner sheath bare steel wire braid armored SHF1 outer sheath flame retardant marine power cable
CEPJRSC/NC/NSCEPR insulated LSZH SHF2 sheath flame retardant marine power flexible cable

EPR Fire resistant Marine Cable Specification

Model

Core

Nominal Cross-section Area

mm2

CEPF/SC/NC/NSC,CEPF80/SC/NC/NSC,CEPF86/SC/NC/NSC

CEPF90/SC/NC/NSC,CEPF96/SC/NC/NSC,CEPFR/SC/NC/NSC

CEPJ/SC/NC/NSC,CEPJ80/SC/NC/NSC,CEPJ85/SC/NC/NSC

CEPJ90/SC/NC/NSC,CEPJ95/SC/NC/NSC,CEPJR/SC/NC/NSC,

1

1~300

2

1~120

3

1~185

4~37

1~2.5

Note:Unlisted cable model can be produced as customer request.

EPR Fire resistant Marine Cable Product Code

Code

Insulation

Code

Inner sheath

Code

Armor

Code

outer Sheath

E

J

V

X

EPR

XLPE(Low Pressure)

PVC

NR-SBR

V

F

H

PF

PJ

PVC

CR

CSP

SHF1

SHF2

0

8

9

 

Copper Wire Braid

Steel Wire Braid

0

2

5

6

PVC

SHF2

SHF1

Code

Definition

Code

Definition

D

S

N

Single Burning

Bundled Burning

Fire resistant

A

B

C

Smoke,Acid,poisonous

Low smoke,Low Acid,Low Poisonous

Halogen Free,Low Smoke,Low Poisonous

Soft------R

Shield ------P

Waterproof------M

EPR Fire resistant marine cable construction

1.Copper conductor C10200 Cu-OF

2.Fire resistant layer Mica tape

3.EPR insulation

4.Filler(if necessary)

5.Tape

6.Inner sheath(PCP/PVC)

7.Metal wire braid(Copper wire braid or Gavalanized steel wire braid)

8.Outer Sheath(PVC)

Q:hi i found out that the cable power that goes from my wall outlet to my wireless router is broken. so i would like to rip some of the plastic and solder and then put some take so the negative and positve wires do not touch. is it safe to do that? thank you. 10 points to the best answer. god bless you.
safe if you do it correctly but not recommended as there is too much chance for problems that could cause a fire later, if the joint came apart or the tape dried up. .
Q:Im not very good with computers but I wanna buy Radeon hd 6850 graphic card, I have a 500 watt psu but I heard I need a 6 pin cable which my psu doesnt have. Can I use a 6 Pin PCI Express Video Card Power Cable Adapter?
Maybe. Some smaller PSUs don't have the right power rails (the way power is distributed to the wires) to do that for a power hungry card. Maybe, but I doubt it, considering the other stuff it must run. Bigger supplies have the correct wire harness for your card.
Q:It isn't the standard power cable, it ALMOST looks like a power cable for a playstation, except it has round on both sides and not just one...Can I JUST buy the plug for it? I lost it when we moved and I need it to make Xmas Cards HAHA
Check okorder they may have part and express shipping Merry Christmas
Q:Hi I purchased a Sony Bluray optical drive from Ebuyer (bad move),The drive showed up in a tackie box with no cables included, manuals etc. I plugged in a SATA cable in to the back but its not powering up, there is a slot for another connection but with no cables enclosed I am I right in saying the SATA cable should power the drive up as well?
A SATA cable alone will not power your drive. There should be a slot with 4 big pins on the blu-ray drive you purchased. Open the case of your computer and find the power supply. There should be cables on it that would fit onto the 4 pins. That would be the power to your drive.
Q:I need to run power cables from 4 fans on my stacker 830 around the edges of the case and into the power supply for cable management purposes. The fans I currently have, have power cables that are around only 10 inches long. Any ideas?
Can you solder? If so, just clip the wires then splice on extensions. Add heat-shrink material, solder connections, shrink the material and you're good to go.
Q:How high voltage armored power cable is grounded
Insulated isolation of the double shield control cable is the outermost armor layer should be grounded at both ends, the inner shield one end of the ground, is conducive to the rapid release of induced current.
Q:What is the concept of power cable middle head? What is the difference between a terminal and a terminal?
Cabling in the integrated wiring system according to the network topology diagram to configure how to connect, no network topology is unable to give the correct connection.
Q:On my original PS3 power cable it says 10A 125V, do I have to make sure the cable I use from a computer matches the same?
yes you can due same due its only a cable
Q:I have been given a Toshiba flat screen tv - the product type is 20VL44G however the power cable has been lost. Does anyone know where I can get a replacement from as I have Googled this and cannot find anything? I am in the UK, thank you all.
If the cable normally fits into a socket on the tv, then you need to describe the socket to us and measure it if possible.
Q:I feel like this is a stupid question but yeah, I m getting a PC and wonder about all the cables. It doesn t have vga output so I m going with a separate hdmi cable to the screen, but power cables I suppose will be there? Like that s not a separate thing ooor...?
depends on 'where' youre getting it from .. a retail bought machine is sure to have all the basic cables for hookup ..

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords