Copper Conductor and Sheath Mineral Insulated Cable
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 100000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Application
It is fit for use in the important occasion, such as explosion resistant, high temperature surrounding, public building, underground facility, transportation and traffic network.
Type and Designation
Type | Designation | Standard |
BTTQ | Light duty copper conductor and sheath Mg0 insulated fire proof cable | IEC60702-1 GB13033.2 Q/321023KLA36 |
BTTVQ | Light duty copper conductor and sheath PVC covering Mg0 insulated fire proof cable | |
BTTZ | 缆Heavy duty copper conductor and sheath Mg0 insulated fire proof cable | |
BTTVZ | Heavy duty copper conductor and sheath PVC covering Mg0 insulated fire proof cable |
Specification
Type | Rated voltage V | Number of core | Nominal cross-section mm2 |
BTTQ BTTVQ | 500 | 1、2 | 1~4 |
3、4、7 | 1~2.5 | ||
BTTZ BTTVZ | 750 | 1 | 1.5~400 |
2、3、4 | 1.5~25 | ||
7 | 1.5~2.5 | ||
5、10、12、19 | 1.5 |
Main characteristics of the cable
1、It has good fire proof, anti-explosion and water proof performance;
2、It has LS0H and non-toxicity characteristic;
3、It has strong high temperature and corrosion resistant capability;
4、It is radiation resistant, and electro-magnetic resistant;
5、It has a big current-carrying capacity and strong over-loading capability;
6、It has good earthing performance.
Technical parameter: Type number of core and nominal cross-section outer diameter rated current-carrying capacity approximate weight Bare cable Cable with anti-corrosion covering bare cable Cable with anti-corrosion covering bare cable Cable with anti-corrosion covering mm2 mm mm A A kg/km kg/km light duty 2×1.0 2×1.5 2×2.5 2×4.0 5.1 5.7 6.6 7.7 6.7 7.3 8.2 9.7 17 22 30 38 20 24 33 44 104 130 179 248 125 153 205 282 3×1.0 3×1.5 3×2.5 5.8 6.4 7.3 7.4 8.0 10.1 15 19 25 17 21 28 135 168 224 159 193 258 4×1.0 4×1.5 4×2.5 6.3 7.0 8.1 7.9 9.0 10.1 15 19 25 16 21 28 161 203 278 187 230 314 7×1.0 7×1.5 7×2.5 7.6 8.4 9.7 9.6 10.4 11.7 10 13 17 11 14 19 172 294 413 207 331 455 heavy duty 1×1.5 1×2.5 1×4.0 1×6.0 1×10.0 1×16.0 1×25.0 1×35.0 1×50.0 1×70.0 1×95.0 1×120.0 1×150.0 1×185.0 1×240.0 1×300.0 1×400.0 4.9 5.3 5.9 6.4 7.3 8.3 9.6 10.7 12.1 13.7 15.4 16.8 18.4 20.4 23.3 26.2 30.6 6.5 6.9 7.5 8.0 9.3 10.3 11.6 12.7 14.1 15.7 17.8 19.2 20.8 23.2 26.1 — — 30 39 51 63 81 107 139 168 207 251 300 344 388 434 483 795 948 33 43 56 69 90 119 154 187 230 279 333 382 431 482 537 883 1053 88 114 140 172 235 319 451 573 764 1018 1298 1576 1890 2323 3031 3832 5228 108 135 162 198 258 356 439 619 816 1076 1386 1674 1997 2468 3197 — — 2×1.5 2×2.5 2×4.0 2×6.0 2×10.0 2×16.0 2×25.0 7.9 8.7 9.8 10.9 12.7 14.7 17.1 9.9 10.7 11.8 12.9 14.7 16.7 19.5 24 32 42 54 74 98 128 26 36 47 60 82 109 142 212 260 342 427 582 845 1138 243 298 385 474 636 907 1238 3×1.5 3×2.5 3×4.0 3×6.0 3×10.0 3×16.0 3×25.0 8.3 9.3 10.4 11.5 13.6 15.6 18.2 10.3 11.3 12.4 13.5 15.6 18.0 20.6 20 27 36 46 62 83 108 22 30 40 51 69 92 120 242 311 399 507 728 980 1370 274 352 444 556 786 1069 1476 4×1.5 4×2.5 4×4.0 4×6.0 4×10.0 4×16.0 4×25.0 9.1 10.1 11.4 12.7 14.8 17.3 20.1 11.1 12.1 13.4 14.7 16.8 19.7 22.9 21 27 36 46 61 80 104 23 30 40 51 68 89 116 298 367 472 623 861 1275 1766 333 411 521 677 923 1376 1909 7×1.5 7×2.5 10.8 12.1 12.8 14.1 14 19 16 21 409 562 455 614
- Q:Hello,I recently bought a kotatsu and I really need some help. The power cable is of course Japanese And I need some type of converter.On the part of the cable that plugs into the radiotaor it says:PSE (It's in some square box)JET MR7A 250VOn the end that plugs into the wall it says:PSE (It's in some square box)JET MR7A 125VI''m not sure if a simple small converter to let me put the Japanese cable into my wall is enough, I think I need something extra to make sure nothing goes into flames.Inside the Japanese instruction manual I found some info However, I'm not really sure if it is related to the power supply or notAC100V 50-60Hz400W3.1 (Probably the length of the cable) 1.3 (Same here I think)140Wh 60 Wh55C 37CPlease help me, what should I get to be able to use the cable in Europe. Any links at all will be helpfulThanks.
- Don't worry too much about what the cord says. Worry about the power requirements on the appliance label, and making sure you are feeding it with the voltage required, with a capacity within the range. In your instance, you will need a converter transformer that converts your outlet voltage to 100V, and has 550 or larger watt capacity.
- Q:i just bought a cobra radar detector and im a bit of a perfectionist. it bothers me that the power supply cable drags from the windshield across the head unit and into the cigarette lighter. i need ideas on how to hook up the detector because it needs to be plugged in to work but not have the cord out in the open. thanks
- Mount the detector on your sunvisor. Run the power cord fromt eh detector under the edge of the headliner and down the A-pillar next to the windshield (you should be able to remove the plastic over the A-pillar and run the cord behind it.) Cut the cigarette lighter plug off and wire it into the fuse panel to a switched 12v source (something that comes on when the car is cranked)(radio, etc). That will allow the radar detector to power on when the car is cranked and to power off when the car is stopped. I wired all of mine like this and never had any problems with any of them.
- Q:I just finished building my shed, I put a 1 1/2 inch conduit under the shed coming up into the corner. I am now about to dig the 65 foot trench back to the house. I need to run power, not a problem. I want to run a phone line, a network cable, and a cable wire for my satellite. I say shed but it is 12 by 20 feet with an attic. Can I run these additional lines in with the power. I was thinking about using a run of Shielded cables for the network and one for the phone. For the cable some heavy duty quot;I don't know what thoughquot;. Will the power lines mess the data up on them? What will work for the three if any. If I need to I could run them in a new conduit, but that is not cheap!
- Congratulations on finishing your shed. Unfortunately, you can't run your communications wiring in the same conduit as a power line. It's against code and it will mess with your low-voltage signals. You'll need to run a separate piece for those. Keep it one foot away from the power conduit, crossing at right angles. Of course, you can run them closer for short distances, but keep it to a minimum. Bear in mind that no matter which satellite cable you choose, it won't like sharp turns. Running shielded cable for the network is a great idea. Also, network cable is getting better every day, run the most highly rated you can afford and you won't regret it. I would not recommend looking for any all-in-one cable. They often are not as well designed as the individual ones. Personally, I would run extra lines now, for future expansion. Hope this helps.
- Q:Where can I buy a power cable with converter for a Dell Inspiron 2200?
- my okorder /
- Q:its a rca home theater system and i need a power cable as my last one broke is there somewere were i can buy one
- There is a 95% chance it uses one of two standard power cord styles TVs these days come with, which is a 3 prong cord identical to what computers come with, or a polarized figure-8 cord, as some portable or bookshelf stereos come with You can get them anyplace that has A/V accessories.
- Q:Yjv22 what is the core of the cable? Copper core or aluminum core?
- sure. Take the ground pipe is to be from the floor under the brick. But the late completion of the drawing to be accurate, so that the next time to repair the line can not find the location. Want to answer to help you.
- Q:Since desktop UPS is ment more for desktop computers, i need UPS to laptop power conversion cable so i will be able to connect desktop UPS to my laptop.
- The battery included in your laptop will out perform any external UPS. The UPS/computer cable is to signal to the computer that the UPS is active so the computer should shut down all active files and applications and wait for the power to crash in a minute or two. The battery in the laptop automatically engages if the power from the AC converter stops. Your computer has several hours to function normally not the minute or two you would get from the UPS.
- Q:I have been given a Toshiba flat screen tv - the product type is 20VL44G however the power cable has been lost. Does anyone know where I can get a replacement from as I have Googled this and cannot find anything? I am in the UK, thank you all.
- Plug interior the ingredient cables, then you ought to do a video reset..the television is attempting to apply the HDMI nonetheless... a million- turn off the potential of your PS3 and then turn it returned on returned. 2- throughout that, carry down the potential button till you spot something on the reveal screen. 3- And that’s approximately it. What it does is, thoroughly resets the video settings to 480p i think of, the priority-unfastened configuration, which facilitates it to paintings on any television or reveal screen.
- Q:Is the ribbon cable the data cable and the wires the power cables?
- Data okorder /
- Q:Sometimes I have to jiggle the chord or plug it in the right position to get the laptop to be charged. At first, I thought it was the power cable, but after buying a new one, I still have the same problem. Any suggestions as to what causes this and how to fix it?
- Pulling on the cable will cause the jack to become deformed, and cause poor connections. You will have to replace the jack. On some laptops, it is an internal plug in module that is easy to replace, on others it is soldered to the motherboard, a much more expensive repair....
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Copper Conductor and Sheath Mineral Insulated Cable
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 100000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products