Copper Conductor and Sheath Mineral Insulated Cable

Copper Conductor and Sheath Mineral Insulated Cable

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
100000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Application

    It  is fit for use in the important occasion, such as explosion resistant,  high temperature surrounding, public building, underground facility,  transportation and traffic network.


Type and Designation

Type

Designation

Standard

BTTQ

Light duty copper conductor and sheath Mg0 insulated fire proof cable

IEC60702-1

GB13033.2

Q/321023KLA36

BTTVQ

Light duty copper conductor and sheath PVC covering Mg0 insulated fire proof cable

BTTZ

缆Heavy duty copper conductor and sheath Mg0 insulated fire proof cable

BTTVZ

Heavy duty copper conductor and sheath PVC covering Mg0 insulated fire proof cable

Specification

Type

Rated voltage

V

Number of core

Nominal cross-section

mm2

BTTQ  BTTVQ

500

1、2

1~4

3、4、7

1~2.5

BTTZ  BTTVZ

750

1

1.5~400

2、3、4

1.5~25

7

1.5~2.5

5、10、12、19

1.5

Main characteristics of the cable

1、It has good fire proof, anti-explosion and water proof performance;

2、It has LS0H and non-toxicity characteristic;

3、It has strong high temperature and corrosion resistant capability;

4、It is radiation resistant, and  electro-magnetic resistant;

5、It has a big current-carrying capacity and strong over-loading capability;

6、It has good earthing performance.

Technical parameter

Type

number of core and nominal cross-section

outer diameter

rated current-carrying capacity

approximate weight

Bare cable

 

Cable with anti-corrosion covering

bare cable

Cable with anti-corrosion covering

bare cable

Cable with anti-corrosion covering

mm2

mm

mm

A

A

kg/km

kg/km

light duty

2×1.0

2×1.5

2×2.5

2×4.0

5.1

5.7

6.6

7.7

6.7

7.3

8.2

9.7

17

22

30

38

20

24

33

44

104

130

179

248

125

153

205

282

3×1.0

3×1.5

3×2.5

5.8

6.4

7.3

7.4

8.0

10.1

15

19

25

17

21

28

135

168

224

159

193

258

4×1.0

4×1.5

4×2.5

6.3

7.0

8.1

7.9

9.0

10.1

15

19

25

16

21

28

161

203

278

187

230

314

7×1.0

7×1.5

7×2.5

7.6

8.4

9.7

9.6

10.4

11.7

10

13

17

11

14

19

172

294

413

207

331

455

heavy duty

1×1.5

1×2.5

1×4.0

1×6.0

1×10.0

1×16.0

1×25.0

1×35.0

1×50.0

1×70.0

1×95.0

1×120.0

1×150.0

1×185.0

1×240.0

1×300.0

1×400.0

4.9

5.3

5.9

6.4

7.3

8.3

9.6

10.7

12.1

13.7

15.4

16.8

18.4

20.4

23.3

26.2

30.6

6.5

6.9

7.5

8.0

9.3

10.3

11.6

12.7

14.1

15.7

17.8

19.2

20.8

23.2

26.1

30

39

51

63

81

107

139

168

207

251

300

344

388

434

483

795

948

33

43

56

69

90

119

154

187

230

279

333

382

431

482

537

883

1053

88

114

140

172

235

319

451

573

764

1018

1298

1576

1890

2323

3031

3832

5228

108

135

162

198

258

356

439

619

816

1076

1386

1674

1997

2468

3197

2×1.5

2×2.5

2×4.0

2×6.0

2×10.0

2×16.0

2×25.0

7.9

8.7

9.8

10.9

12.7

14.7

17.1

9.9

10.7

11.8

12.9

14.7

16.7

19.5

24

32

42

54

74

98

128

26

36

47

60

82

109

142

212

260

342

427

582

845

1138

243

298

385

474

636

907

1238

3×1.5

3×2.5

3×4.0

3×6.0

3×10.0

3×16.0

3×25.0

8.3

9.3

10.4

11.5

13.6

15.6

18.2

10.3

11.3

12.4

13.5

15.6

18.0

20.6

20

27

36

46

62

83

108

22

30

40

51

69

92

120

242

311

399

507

728

980

1370

274

352

444

556

786

1069

1476

4×1.5

4×2.5

4×4.0

4×6.0

4×10.0

4×16.0

4×25.0

9.1

10.1

11.4

12.7

14.8

17.3

20.1

11.1

12.1

13.4

14.7

16.8

19.7

22.9

21

27

36

46

61

80

104

23

30

40

51

68

89

116

298

367

472

623

861

1275

1766

333

411

521

677

923

1376

1909

7×1.5

7×2.5

10.8

12.1

12.8

14.1

14

19

16

21

409

562

455

614

Q:Hello,I recently bought a kotatsu and I really need some help. The power cable is of course Japanese And I need some type of converter.On the part of the cable that plugs into the radiotaor it says:PSE (It's in some square box)JET MR7A 250VOn the end that plugs into the wall it says:PSE (It's in some square box)JET MR7A 125VI''m not sure if a simple small converter to let me put the Japanese cable into my wall is enough, I think I need something extra to make sure nothing goes into flames.Inside the Japanese instruction manual I found some info However, I'm not really sure if it is related to the power supply or notAC100V 50-60Hz400W3.1 (Probably the length of the cable) 1.3 (Same here I think)140Wh 60 Wh55C 37CPlease help me, what should I get to be able to use the cable in Europe. Any links at all will be helpfulThanks.
Don't worry too much about what the cord says. Worry about the power requirements on the appliance label, and making sure you are feeding it with the voltage required, with a capacity within the range. In your instance, you will need a converter transformer that converts your outlet voltage to 100V, and has 550 or larger watt capacity.
Q:i just bought a cobra radar detector and im a bit of a perfectionist. it bothers me that the power supply cable drags from the windshield across the head unit and into the cigarette lighter. i need ideas on how to hook up the detector because it needs to be plugged in to work but not have the cord out in the open. thanks
Mount the detector on your sunvisor. Run the power cord fromt eh detector under the edge of the headliner and down the A-pillar next to the windshield (you should be able to remove the plastic over the A-pillar and run the cord behind it.) Cut the cigarette lighter plug off and wire it into the fuse panel to a switched 12v source (something that comes on when the car is cranked)(radio, etc). That will allow the radar detector to power on when the car is cranked and to power off when the car is stopped. I wired all of mine like this and never had any problems with any of them.
Q:I just finished building my shed, I put a 1 1/2 inch conduit under the shed coming up into the corner. I am now about to dig the 65 foot trench back to the house. I need to run power, not a problem. I want to run a phone line, a network cable, and a cable wire for my satellite. I say shed but it is 12 by 20 feet with an attic. Can I run these additional lines in with the power. I was thinking about using a run of Shielded cables for the network and one for the phone. For the cable some heavy duty quot;I don't know what thoughquot;. Will the power lines mess the data up on them? What will work for the three if any. If I need to I could run them in a new conduit, but that is not cheap!
Congratulations on finishing your shed. Unfortunately, you can't run your communications wiring in the same conduit as a power line. It's against code and it will mess with your low-voltage signals. You'll need to run a separate piece for those. Keep it one foot away from the power conduit, crossing at right angles. Of course, you can run them closer for short distances, but keep it to a minimum. Bear in mind that no matter which satellite cable you choose, it won't like sharp turns. Running shielded cable for the network is a great idea. Also, network cable is getting better every day, run the most highly rated you can afford and you won't regret it. I would not recommend looking for any all-in-one cable. They often are not as well designed as the individual ones. Personally, I would run extra lines now, for future expansion. Hope this helps.
Q:Where can I buy a power cable with converter for a Dell Inspiron 2200?
my okorder /
Q:its a rca home theater system and i need a power cable as my last one broke is there somewere were i can buy one
There is a 95% chance it uses one of two standard power cord styles TVs these days come with, which is a 3 prong cord identical to what computers come with, or a polarized figure-8 cord, as some portable or bookshelf stereos come with You can get them anyplace that has A/V accessories.
Q:Yjv22 what is the core of the cable? Copper core or aluminum core?
sure. Take the ground pipe is to be from the floor under the brick. But the late completion of the drawing to be accurate, so that the next time to repair the line can not find the location. Want to answer to help you.
Q:Since desktop UPS is ment more for desktop computers, i need UPS to laptop power conversion cable so i will be able to connect desktop UPS to my laptop.
The battery included in your laptop will out perform any external UPS. The UPS/computer cable is to signal to the computer that the UPS is active so the computer should shut down all active files and applications and wait for the power to crash in a minute or two. The battery in the laptop automatically engages if the power from the AC converter stops. Your computer has several hours to function normally not the minute or two you would get from the UPS.
Q:I have been given a Toshiba flat screen tv - the product type is 20VL44G however the power cable has been lost. Does anyone know where I can get a replacement from as I have Googled this and cannot find anything? I am in the UK, thank you all.
Plug interior the ingredient cables, then you ought to do a video reset..the television is attempting to apply the HDMI nonetheless... a million- turn off the potential of your PS3 and then turn it returned on returned. 2- throughout that, carry down the potential button till you spot something on the reveal screen. 3- And that’s approximately it. What it does is, thoroughly resets the video settings to 480p i think of, the priority-unfastened configuration, which facilitates it to paintings on any television or reveal screen.
Q:Is the ribbon cable the data cable and the wires the power cables?
Data okorder /
Q:Sometimes I have to jiggle the chord or plug it in the right position to get the laptop to be charged. At first, I thought it was the power cable, but after buying a new one, I still have the same problem. Any suggestions as to what causes this and how to fix it?
Pulling on the cable will cause the jack to become deformed, and cause poor connections. You will have to replace the jack. On some laptops, it is an internal plug in module that is easy to replace, on others it is soldered to the motherboard, a much more expensive repair....

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products