• Galvanized Steel Wire Rope Steel Wire Ropes  With High Quality System 1
Galvanized Steel Wire Rope Steel Wire Ropes  With High Quality

Galvanized Steel Wire Rope Steel Wire Ropes With High Quality

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
5 m.t.
Supply Capability:
100 m.t./month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

steel wire rope
6*37+FC/IWS/IWR
6*7+FC/IWS
6*19+FC/IWS/IWR
6*24+7FC 6*15+7FC Be used for crane,hoist,engineering

galvanized steel wire rope

1.  Application:

Crane, Hoist and General Engineering Purposes

2.  Characteristic:

Good wear resistance and longer fatigue life

As per GB,JIS, RR-W,API and etc ,as well as customer`s request

3.   Surface Coating: Galvanizing

4.  Packing type: Wooden reel

Q:2 long striaght wires (20m each) ,each having a 1.0A current going up.The distance between the two wires is 1.0m(a) what is the magnetic field (magnitude and direction) at a point o.50m left of the wire 1?(b)what is the magnetic field (magnitude and direction) at a point 0.6m right of Wire 1?
Assuming Wire 2 is to the right of Wire 1: a) Bwire1 = (u*I)/(2*pi*r) = ((4*pi*10^-7)*1A)/(2*pi*0.5) = 0.000004 Bwire2 = 0.000000424 Btotal = 0.000004424 (away from wire 1) b) Bwire1 = 0.000003333 Bwire2 = 0.000005 Btotal = -0.0000017 (toward Wire 1)
Q:How can I stop my cat from chewing wires? He does it all the time, and the wire he ends up being important.
If you find a good answer, please let me know. I have a 4 year old cat- still doing that - and they are also very important wires. You think they would be electrocuted-especillay when they are plugged in- but he is still ticking strong and chewing! Computer wires, radio antennas, headphone wires- its crazy! He also chews on plants- I wish I knew what to do! Good luck with an answer!
Q:Me and a buddy took the 305 out of the car. I have a 350 to take its place, but was wondering what are the only wires i need to have a clean engine bay. the old engine has a million wires hooking up to everything. Some muscle cars only have spark plug wires, the starter wire and battery cable. What must i do to get mine like that? i dont care about emissions. what must i change or add to the new engine?
I have an '84 Monte SS and wanted the same thing. Here's what I have: the 2 wires that come from the harness and go to the starter (1 Positive, 1 S terminal), oil gauge wire, temp gauge wire, the alternator wires, the wire going to the distributor cap, and the tach gauge wire going to the distributor cap. That's pretty much it, as well as your battery cables, and spark plug wires. You really don't need to do or add anything as long as it runs and everything works that needs to work, it'll be fine. I'm going by memory, so if I forgot something I apologize, but that's the best of my recollection right now. If you have anymore questions you can email me.
Q:What exactly is 6 AWG stranded grounding wire usually used for?
In a nutshell: a) Verify that your service drop has the capacity for the additional load - verify this with your utility. b) If you are planning to install a 200A service in the barn, and you are planning to bury the wire, you will need to use 3-0 wire in a conduit. Use separate conductors. Check with your local electrical inspector, but I do not believe you will need to run a separate ground within the conduit for this application. The code may have changed, however. c) You will need to install a 200A fused safety-switch at the pole, and a new 200A panel in the barn. d) The barn panel will also have a 200A main disconnect breaker in it. e) You will need to install an additional ground-rod (or rods) at the barn panel. 1. DO NOT use old/used wire. 2. Consider running triplex wire overhead as it will be less expensive and equally effective. 3. Get the work inspected by an underwriter - your fire insurance will be voided if you do not. Lastly, it is not rocket science, but the codes and standards that apply are there for a reason - follow them carefully and fully and you will be fine.
Q:The coiled wire is for making bucktails and i would like to buy it in bulk.
lowes maybe or home depot.
Q:hi i have 2000 prizm the wires coming out of car doesnt match the colours of stereo wires does and body knows the wiring coding for car to sony cd player thanks
this the wire-hares that you need and the dash kit. 70-2003 wiring harness 99-3413 dash kit if you have any more question you can IM me any time. KS AUDIO OWNER KIM
Q:I have a wire coming up from my basement that has 3 wires (red, green and yellow). I want to connect cat5 wire to that (twisting the wires together) and run the cat5 to an RJ45 box. What's my diagram going to look like?
Cat5 requires 4 wires (two pairs) - you cannot use old telephone wire. second, if the old phone was was 2 pair, you still could not use it. Cat5 is good to just over 300MHz. The old voice grade JK cable could not transfer data very fast. Just use the old phone wire as a pull. Connect a new run of Cat6 to the old wire and pull the new wire into place using the old wire as a pull string.
Q:Is there really a difference between audio wire and regular house wire? If you say yes then please explain, in understandable scientific terms why, or point me to a site that can.
Yes there is a difference because a amp needs a certian amount of amps to work. You can use any kind of wire, hell u can even use a coat hanger, what happens when you use the worng guage wire is you put a strain on the device. That is why amps run hot, or pop fuses, and you wont get the full potential of the amp, shorten its life etc.
Q:What's the thickness, or measurement for the last or thickest wire?
they change your wire according to how much your teeth have shifted around, so it just depends. the ortho needs to adjust the size of the wire due to your teeth straightening out and making sure the wire(s) are at a correct length. its really not that thick of a wire, so don't worry about it. :D
Q:I'm just wondering would i be able to connect a split 8 gauge wire with wire nuts like i'll explain:Use two wire nuts instead of one and divide the copper wire on both ends and wire nut both sides together with 2 nuts. The whole apparatus would look kinda like this:----lt;gt;---- with the wire nuts connecting the two arrow thingsThanks anyone
8 gauge wire is fairly heavy so I'll assume that this is not a low power application such as speaker drivers. I assume you want to do this because you don't have a proper connecting method of adequate size and you do have a couple of smaller size wire nuts. The proposed configuration would not be acceptable by any electric code for utility wiring for this reason. If one of those wire nut connections should fail, say due to corrosion or mechanical damage, the remaining connection would be required to carry the entire current load that both would normally share. This would no longer be adequately protected by a circuit breaker sized for the full 8 gauge wire. A high resistance point is developed with a high fire risk. Also the wire nuts would not be able to shield the conductors beyond the end of the wire insulation sheath. The exposed wire portions would need additional protection from incidental contact by some future service person. Please don't do this. Not a good practice.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords