Aerial Insulated Cables within Rated Voltage 10KV and 35KV
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications
1.good manufacturer with 30 years' experience
2.good qualiy&competitive price
3.on time delivery
4.good after-sale service
Product standard
The product is manufactured according to the standards of GB14049“Aerial insulated cables of rated voltages 10 KV and 35KV” and IEC60502“Extruded solid dielectric power cables for rated voltages from 1KV to 30KV”.
Operating characteristics
Rated voltage: 10KV, 35KV:
Max. permissible continuous temperature:
HDPE insulated aerial cables: 75℃; XLPE insulated aerial cables: 90℃
Max. short circuit temperature of the conductor shall not exceed:
HDPE insulated aerial cables: 150℃; XLPE insulated aerial cables: 250℃
The installation ambient temperature should not below -20℃
The bending radius of cables are recommended as follows:
Single cable: not less than 20 times the diameter of cables; Multi-core cables: not less than 15 times the diameter of cables.
Type/Designation
Type | Designation |
JKYJ | Copper conductor XLPE insulated aerial cables |
JKTRYJ | Flexible copper conductor XLPE insulated aerial cables |
JKLYJ | Aluminum conductor XLPE insulated aerial cables |
JKLGYJ | ACSR conductor XLPE insulated aerial cables |
JKLHYJ | Aluminum alloy conductor XLPE insulated aerial cables |
JKY | Copper conductor PE insulated aerial cables |
JKTRY | Flexible copper conductor PE insulated aerial cables |
JKLY | Aluminum conductor PE insulated aerial cables |
JKLGY | ACSR conductor PE insulated aerial cables |
JKLHYJ/Q | Aluminum alloy conductor light type XLPE thinness insulated aerial cables |
JKLGYJ/Q | ACSR conductor light type XLPE thinness insulated aerial cables |
JKLY/Q | Aluminum conductor light type XLPE thinness insulated aerial cables |
JKLHY/Q | Aluminum alloy conductor light type PE thinness insulated aerial cables |
JKLGY/Q | ACSR conductor light type PE thinness insulated aerial cables |
Type of cable
Type | Cores Number | Rated Voltage KV | |
10 | 35 | ||
Nominal Cross-Section of conductor mm2 | |||
JKYJ, JKTRYJ, JKLYJ, JKLHYJ, JKLGYJ | 1 | 10~300 | 50~300 |
JKY, JKTRY, JKLY, JKLHY, JKLGY, JKLYJ/Q, JKLHYJ/Q, JKLY/Q, JKLHY/Q, JKLGYJ/Q, JKLGY/Q | 1 | 10~300 |
|
Construction and technical parameter of cable
10KV Single-core copper aluminum and aluminum alloy conductor common insulated aerial cables of rated voltage | ||||||
Nominal cross-sectional area of conductor | Cable approx. diameter | Cable approx Weight | Tensile force of cable | |||
JKY JKTRY JKYJ JKTRYJ | JKLY JKLHY JKLYJ JKLHYJ | Hard Copper | Aluminum | Aluminum alloy | ||
mm2 | mm | Kg/km | Kg/km | N | ||
10 | 11.8 | 190 | 127 | 3471 | 1650 | 2514 |
16 | 12.8 | 257 | 158 | 5486 | 2512 | 4022 |
25 | 14.0 | 345 | 195 | 8465 | 3762 | 6284 |
35 | 15.0 | 450 | 235 | 11731 | 5177 | 8800 |
50 | 16.3 | 575 | 285 | 16502 | 7011 | 12569 |
70 | 17.8 | 670 | 257 | 23461 | 10354 | 17596 |
95 | 19.7 | 1045 | 463 | 21759 | 13727 | 23880 |
120 | 21.1 | 1285 | 550 | 39911 | 17339 | 30164 |
150 | 22.7 | 1580 | 655 | 49505 | 21033 | 37706 |
185 | 24.2 | 1855 | 755 | 61846 | 26732 | 46503 |
240 | 26.5 | 2380 | 935 | 79823 | 34679 | 60329 |
300 | 28.7 | 3000 | 1145 | 99788 | 43349 | 75411 |
35KV Single-core copper aluminum and aluminum alloy conductor common insulated aerial cables of rated voltage | ||||||
Nominal cross-sectional area of conductor | Cable approx. diameter | Cable approx Weight | Tensile force of cable | |||
JKYJ JKTRYJ
| JKLYJ JKLHYJ
| Hard Copper | Aluminum | Aluminum alloy | ||
mm2 | mm | Kg/km | Kg/km | N | ||
50 | 31.5 | 1184 | 874 | 16502 | 7011 | 12569 |
70 | 33.2 | 1421 | 987 | 23461 | 10354 | 17596 |
95 | 34.8 | 1703 | 1114 | 21759 | 13727 | 23880 |
120 | 36.2 | 1975 | 1231 | 39911 | 17339 | 30164 |
150 | 37.8 | 2301 | 1371 | 49505 | 21033 | 37706 |
185 | 39.4 | 2666 | 1519 | 61846 | 26732 | 46503 |
240 | 41.6 | 3231 | 1743 | 79823 | 34679 | 60329 |
300 | 43.8 | 3844 | 1984 | 99788 | 43349 | 75411 |
10KV Single-core ACSR Conductor aerial insulated cable | |||||||
Nominal cross-sectional area of conductor Al/Fe | Single Cable approx. diameter | Single Cable approx Weight | Single Tensile force of cable | Nominal cross-sectional area of conductor Al/Fe | Single Cable approx. diameter | Single Cable approx Weight | Single Tensile force of cable |
mm2 | mm | Kg/km | N | mm2 | mm | Kg/km | N |
25/4 | 14.4 | 239 | 9290 | 185/10 | 24.7 | 862 | 40880 |
35/6 | 15.6 | 295 | 12630 | 185/25 | 25.6 | 987 | 59420 |
50/8 | 16.9 | 367 | 16870 | 185/30 | 25.8 | 1005 | 64320 |
50/30 | 18.9 | 565 | 42620 | 185/45 | 26.4 | 1032 | 80190 |
70/10 | 18.7 | 473 | 23390 | 210/10 | 25.9 | 1147 | 45140 |
70/40 | 21.1 | 743 | 58300 | 210/25 | 26.8 | 963 | 65990 |
95/15 | 20.9 | 610 | 35000 | 210/35 | 27.1 | 1102 | 74250 |
95/20 | 21.1 | 639 | 37200 | 210/50 | 27.7 | 1163 | 90830 |
95/55 | 23.3 | 966 | 78110 | 240/30 | 28.0 | 1286 | 75620 |
120/7 | 21.6 | 614 | 27570 | 240/40 | 28.3 | 1225 | 83370 |
120/20 | 22.4 | 723 | 41000 | 240/55 | 29.0 | 1286 | 102100 |
120/25 | 22.7 | 770 | 47880 | 300/15 | 29.4 | 1434 | 68060 |
120/70 | 25.2 | 1176 | 98370 | 300/20 | 29.6 | 1280 | 75680 |
150/8 | 23.1 | 731 | 32860 | 300/25 | 29.9 | 1380 | 83410 |
150/20 | 23.8 | 827 | 46630 | 300/40 | 30.3 | 1479 | 92220 |
150/25 | 24.1 | 874 | 54110 | 300/50 | 30.7 | 1563 | 103400 |
150/35 | 24.6 | 961 | 65020 | 300/70 | 31.5 | 1752 | 128000 |
10KV Single-core ACSR Conductor light type thin insulated aerial cable | |||||||
Nominal cross-sectional area of conductor Al/Fe | Single Cable approx. diameter | Single Cable approx Weight | Single Tensile force of cable | Nominal cross-sectional area of conductor Al/Fe | Single Cable approx. diameter | Single Cable approx Weight | Single Tensile force of cable |
mm2 | mm | Kg/km | N | mm2 | mm | Kg/km | N |
25/4 | 11.6 | 177 | 9290 | 185/10 | 21.7 | 742 | 40880 |
35/6 | 12.8 | 227 | 12630 | 185/25 | 22.6 | 863 | 59420 |
50/8 | 14.1 | 293 | 16870 | 185/30 | 22.8 | 907 | 64320 |
50/30 | 16.1 | 482 | 42620 | 185/45 | 23.4 | 1019 | 80190 |
70/10 | 15.9 | 390 | 23390 | 210/10 | 22.9 | 835 | 45140 |
70/40 | 18.1 | 642 | 58300 | 210/25 | 23.8 | 972 | 65990 |
95/15 | 17.9 | 509 | 35000 | 210/35 | 24.1 | 1032 | 74250 |
95/20 | 18.1 | 538 | 37200 | 210/50 | 24.7 | 1151 | 90830 |
95/55 | 20.3 | 853 | 7 8110 | 240/30 | 25.0 | 1088 | 75620 |
120/7 | 18.6 | 511 | 27570 | 240/40 | 25.3 | 1148 | 83370 |
120/20 | 19.4 | 615 | 41000 | 240/55 | 26.0 | 1292 | 102100 |
120/25 | 19.7 | 661 | 47880 | 300/15 | 26.4 | 1136 | 68060 |
120/70 | 22.2 | 1054 | 98370 | 300/20 | 26.6 | 1182 | 75680 |
150/8 | 20.1 | 620 | 32860 | 300/25 | 26.9 | 1234 | 83410 |
150/20 | 20.8 | 712 | 46630 | 300/40 | 27.3 | 1331 | 92220 |
150/25 | 21.1 | 758 | 54110 | 300/50 | 27.7 | 1413 | 103400 |
150/35 | 21.6 | 842 | 65020 | 300/70 | 28.5 | 1597 | 128000 |
- Q:i am going to establish a new power cable manufacturing business. i want to ask you what should i name to my business or what brand name should i adopt that is appopriate.
- follow the suggestions. Good Luck
- Q:I got a free graphics card from my cousin and my computer only has the SATA slots for graphic cards and the one he gave me has the 4 Pin cable. Is there anyway to get it converted or any cables that can go from 4 Pin to sata? I wanna see how this graphics card goes when its working fully.
- Sure you don't have any molex connectors at all? Not even in your DVD drive? If so, get a Y adapter with a good amount of length. If not, then look for an adapter. Be careful as the vast majority are to convert a molex power cable to a SATA power connector, not the other way around. In the worst case you could hook up a separate power supply to it.
- Q:If you have an electrical device (e.g. a laptop), you'll sometimes notice that near the place where you plug the power adapter into it, there's a sign. It's composed of 3 circles, minus on the left, O inside a C in the middle, and plus on the right.What is this? And if I want to read/learn more about it where should I go?
- If you look at the jack that go inside the power input you will see that it is an outside connect and an inside one.The O is the inside connect and the C is the outside one.Because it is a DC power adapter it has a + and - polarity .O,the inside ,is the plus and C,the outside,is the minus. Also on the adapter you can see the same thing! This is because some brands use the outside connect as + and you can burn your device if you use it!!!!
- Q:Since the ps3 uses a universal power cable can any of those cables workthe original cable says 10A and 125v and the other non original says the same it fits however is it safe???
- If you are talking about the HDMI cable that goes from your HD TV to the ps3 - then you have to find out the resolution that your tv supports and then find a HDMI cable that matches that resolution you can get these cables at major electronics stores It is best to have a HD TV with the HD cable (improves graphics)
- Q:why my pc is shutting down and restarting only when removing the power cable and connecting it again?
- It's shutting down because you're removing the power cable. I wouldn't really do that when your computer is on... It's not good for the motherboard or anything, for that matter. It restarts again basically because it's still being told it's on, so it reboots when it's plugged back in.
- Q:ok ive been having amp trouble lately. it wont turn on. ive figured the problem today when i got the voltage tester out. I have me Remote Turn On working.My ground is solid.RCAs connected properly.NO fuses are blown. ive checked all of them; 30 amp fuse for AMP, Max fuse under the hood, fuse relay center under the hood too, all good. connection from the power terminal is solid. heres what happened: i decided to move my amp and run the wires under the door sills because i needed more space. so i just had the car off and i disconnected my remote, power, and rcas. i left the ground because that didnt need to be moved.i dropped the power wire and it hit a seatbelt thing, and it sparked once. but not big.nothing blew, but now it seems like my power wire isnt working, my amp wont turn on-keep in mind my amp was not touched by the spark in any way.
- that's odd. a power wire is way too big to burn and lose conductivity. no way, not on car amperage. u can look up any manufacturer dealer authorized electronics shop, or any electronics shop and have them bench test the amp to be safe. My guess is the conductivity of the power wire is compromised. look at the battery terminal connections, remove and clean them. maybe burnt. this is odd. seriously I installed many systems and I have sparked and no issues. also shorted battery ( i doubt) and as the man above says, main fuse / relay
- Q:I'm trying to run a cable and power outlet into a closet for a media space but im not sure how to add the outlets in there. The area where the closet is, is on a wall that has no outlets and behind the closet is a bathroom which has no outlets on that side of the wall either so theres nothing to tap into. please help.thank you.
- This is for a media closet, so more than a couple things will be plugged in right? Consider pulling a new circuit back to the panel. You can also tap into an existing circuit by finding the last receptacle on that line and dropping a new cable down the wall into the box. Try not to load the circuit above 80% of it's rating, so 15=12A, 20=16A. I'm assuming you have an unfinished attic or basement as you already plan to run media cable.
- Q:Will it work if I put a pigtail (connect the wires by twisting them together) or does that stop it from working properly..
- It is possible to reconnect a severed cable... but unless you know what you are doing and have the special tools and parts to make a proper splice, I would not attempt to do so. The current passing through the laptop transformer is pretty high voltage stuff. If you should happen to cross-connect or develop a short across your splice, you could get a nasty shock, fry your computer or even start a fire. Electricity can be tricky stuff. Make sure you know what you are doing or you, your computer or the both of you could end up in a very bad way. In the long run, you're much better off simply buying a new replacement power supply. Good luck! ***ADDITIONAL*** If the battery light is constantly blinking, the battery in the computer could be dead as well (not surprising given the state of the charger). You probably need to replace both the battery and the charger.
- Q:Did not find the relevant norms. Fiber optic cable should not be affected by interference, electric corrosion this piece without taking into account? More
- My computer --- right-click properties. Device Manager. Look at the USB device is not there or the number. Have to reinstall the system. Also make sure your motherboard USB interface is not good. I said the interface is plug USE jumper of the root.
- Q:Hi, just moved to Finland from US. Will my x box 360 works with a new powell cable? Or do I need something else besides that. And where should I get it from in Turku or Helsinki. Thank you!
- You could probably buy an adapter plug for your existing cable. Getting a whole new cable might very well mess with the machine itself, and be more expensive than a simple adapter. Just go to an electronics’ store, with the cable, (the bigger the better) and ask for a suitable adapter for it.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Aerial Insulated Cables within Rated Voltage 10KV and 35KV
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Related keywords