Specifications
Excellent acid and alkali erosion endurance.
Low power,small size.
Portable and endurable.
electrical magnetic pump, Seal less magnetic pump, permanent magnet water pump Characteristic:
1.Magnetic Driver design without shaft seal.Sealing up completely, There is no leakage of chemical liquid . It's good for the environment,
2.It's apply to Chemical liquid(acid or alkali) transportation.
3.Pump applicable temperature:GFRPP-75 °C , CPVC-80°C,PVDF-90°C. Pump material decided by chemical liquid properties.
electrical magnetic pump, Seal less magnetic pump, permanent magnet water pump Details:
1. Model :MP
2.Pump Material:F-GFRPP A-CPVC P-CFRPVDF E-CFRETFE
3.Power:203-45W 204-65W 255-90W 257-150W 258-260W
4.Connection Type of inlet/outlet :S-screw type H- Straight pipe type
5.Pump spindle:C-CERAMIC T-TITANIUM(Ti) S-SIC
6.Rubber Material :E-EPDM V-VITON
7.Frequency :5-50Hz 6-60Hz
8.Voltage :V11-110V/220V/1ø V38-220V/380V/3 ø
- Q:Water pump spoon pipe for power plantWhich hero can tell me what is the water pump spoon tube ah? And its role
- The spoon pipe is not a feed pump, but also is an adjusting oil inlet device of a hydraulic coupler matched with a feed pump
- Q:What are the general water pump failure, how to repair?
- (4) because of the long latent water and the corrosion of the pipe wall, the water inlet of the water inlet is constantly dropping. When the holes appear above the water, the air enters the water inlet pipe from the hole.(5) there is a crack at the bend of the inlet pipe, and there is a small gap between the inlet pipe and the water pump, which may cause the air to enter the inlet pipe.
- Q:How many square cables does the submersible pump for 7.5KW need?
- I=P/ (1.732Ucos phi) =7.5/ (1.732X0.38X0.85) =13A (calculated according to three-phase city power, power factor 0.85).
- Q:Does the control cabinet of the fire control pump need to be related to the fire control room?
- The relationship is simple, the fire pump is pressurized water supply device, the control cabinet is the power supply for the fire pump, the regulator tank is to stabilize the pressure of the network management, reduce the pump frequently start device.
- Q:How can the submersible pump level meter be connected?
- Install liquid level controller, two position liquid level sensor, controller to buy manual, wiring according to wiring diagram.
- Q:Hydraulic pump displacement refers to the pump shaft what?
- Displacement of the hydraulic pump refers to the axis of each turn, the volume discharged, called displacement, the unit is ml (ML),
- Q:Does vacuum pump oil belong to dangerous goods?
- Is the grease inside? How could it be dangerous goods? Absolutely not!
- Q:The difference between diaphragm pumps, vacuum pumps and centrifugal pumps
- The diaphragm works by changing the size of the diaphragm. When the cup is covered with an eraser and the edge is airtight, then pressing the rubber or pulling the rubber outward will make the pressure in the cup increase or decrease. Use this principle, in the pressure of an hour from a hole suction medium, when the pressure is large, from another hole extrusion medium, so as to achieve the purpose of conveying.
- Q:Do you have a suction pump higher than 9 meters?
- Pump rated suction generally 7 meters or so, it is estimated that no one calibration pump suction stroke 9 meters. Calibration suction range of 9 meters is not reliable.
- Q:Fire control center manually start the fire pump directly, multi line control, called straight up line NHKVV-7*1.5, my understanding is: straight line from fire control center
- The line between the fire pump buttons should be NHBVR-4*1.5 lines. 2 start, 2 answer. Some manufacturers reported that the 3 lines can also, this need to see which is the specific equipment. In addition, we need to introduce 2 warning buses.The above lines are individually distributed
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Permanent Magnet pumps
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Related keywords