• Medium-Voltage XLPE insulated power cable System 1
Medium-Voltage XLPE insulated power cable

Medium-Voltage XLPE insulated power cable

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

pecifications

CU/XLPE/CTS/PVC/SWA/PVC multicore cable
good xlpe power cable
Medium Voltage armoured cable up to 35kV
IEC, GB, CE, CCC, KEMA

Constructions

Conductor

Compact Stranded Copper Conductor, Class 2 as per IEC 60228

Circular solid Copper Conductor, Class 1 as per IEC 60228

Conductor Screen

Semi-conductor

Insulation

XLPE(Cross-linked polyethylene)

Insulation Screen

Semi-conductor

Separate Screen

Copper Tape

Filler

PP Yarn, or Paper

Wrapping Tape

PP

Inner Covering

Extruded PVC

Armour

Steel Wire

Overall Sheath

PVC

Applications

Used for power transmission and distribution line with voltage rated at 6 - 35kV.

Compared with PVC Insulated Power Cable, xlpe power cable boasts not only characteristics of excellent electricity, mechanism, heat and aging-resistant, environment stress-resistant and chemical corrosion-resistant, but also simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working.

Standards

International: IEC 60502-2, IEC 60228

China: GB/T 12706.2-2008

Other standards such as BS,DIN and ICEA upon request

Technical data

Rated voltage: 6/6kV, 6/10kV, 8.7/10kV, 8.7/15kV, 12/20kV, 21/35kV, 26/35kV

Maximum Conductor Temperature: under normal (90°C), emergency (130°C) or short circuit no more than 5s (250°C) conditions.

Min. Ambient Temp. 0°C, after installation and only when cable is in a fixed position

Min. Bending Radius: 12 x cable O.D for multi-core armoured cables

Certificates

CE, RoHS, CCC, KEMA and more others at request


Q:Cable zc_y v22 what does it mean
If you put seven 1.0 square conductor twisted together, as a power can of course. But you twisted the copper wire, how to solve the insulation? In addition, the manual twist, then there is the problem of density, can not be a bit twisted copper wire twisted round? And if you put the seven core core is not peeling, directly twisted together, then, when the wire when the core heat how you solve. So, do not use this line to do home improvement. But if you want to use this line to do the lamp line or can.
Q:Hello guyzz, recently i have bought new card powercolor radeon hd 6770 1gb gddr5 .i installed it but it required a 6 pin power cable forbut i checked in my all pc..i cant fine any 6 pin power cable.so without any cable its not working wat i do plzzz help.......
This is something you should check before you buy the video card. The card may have come with an adapter that plugs into a couple of your ide molex power connectors, and has the 6 pin connector you need on the other side. That might do it for you. Unless you don't have ide power connectors either. Or you can buy a new power supply. If your current power supply isn't big enough to support the new card you may end up buying a new power supply anyway.
Q:I disconect them and now, i don't know how to put them back like they supposed to. Can someone please tell me how to do this? please!!This is some of the information that i got from my PC.OS NameMicrosoft Windows XP ProfessionalVersion5.1.2600 Service Pack 2 Build 2600OS ManufacturerMicrosoft CorporationSystem NameMY-DBVYSKQ1KC1OSystem ManufacturerVIA Technologies, Inc.System ModelKM266-8235System TypeX86-based PCProcessorx86 Family 6 Model 6 Stepping 2 AuthenticAMD ~1396 MhzBIOS Version/DatePhoenix Technologies, LTD 6.00 PG, 11/7/2002SMBIOS Version2.2Windows DirectoryC:#92;WINDOWSSystem DirectoryC:#92;WINDOWS#92;system32Boot Device#92;Device#92;HarddiskVolume1LocaleUnited StatesHardware Abstraction LayerVersion = quot;5.1.2600.2180 (xpsp_sp2_rtm.040803-2158)quot;User NameMY-DBVYSKQ1KC1O#92;myTime ZoneEastern Standard TimeTotal Physical Memory512.00 MBAvailable Physical Memory79.05 MBTotal Virtual Memory2.00 GBAvailable Virtual Memory1.96 GBPage File Space817.16 MBPage FileC:#92;pagefile.sys
If your talking about the power cables from the power supply to the motherboard those are fairly straight forward. It is a 20 or, 24 pin connector. Usually along the edge opposite the external connections for the motherboard. Although, the placement really depends on the manufacturer and, could even be near the middle of the board. They are keyed and, you can not plug them in incorrectly. As long as you don't force them into the slot. If your speaking of the wires from the case to the motherboard that is a little more difficult. P3 and, P4 motherboards usually have a keyed connection that simply plugs in. Other boards have markings on each of the wires corresponding with it's connection. The one thing that is the same for every board is that the two black wires must be side by side. If you've never done it before you should have labeled each wire and, made a diagram of their placement. Your best hope short of taking your computer to the local shop is to try and, find diagrams for both your motherboard and, the case.
Q:HiIs it advisable to run 110VAC cable from the sub stationa and 110VAC cable from generator (clean) in the same conduit ; one of them for lighting and the other for CCTV; the concern is if the one for lighting is not clean (not consisting of a pure sine wave or carrying interference) would that effect the power line of the CCTV and has an effect on the picture? even though both are 110VAC.the installation is over seas where the power from the station is not consistence.
If both are simple power lines, then you won't have a problem. The only time you need to be cautious is when you are running a high-voltage power cable and a signal cable alongside each other e.g. a 110VAC cable alongside a 4-20ma signal line from a transmitter. The reason for the potential interference is that the power cable emits an electro-magnetic field which can potentially cause induction in the cable alongside it and effect the signal with an induced EMF. The likelihood of this depends on the cable type, screening and correct earthing measures. It's a good bet to never run a power and signal cable alongside each other, and if you have no other choice, seperate them by means of a makeshift Faraday Cage. If both are doing nothing other than supplying power to the system though, then any induced EMF will be so minute, it will not likely affect the system in any way.
Q:Power cable yjv22-10kv-3 * 50 what it means
10kV XLPE insulated steel tape armored PVC sheathed power cable three core 50mm2
Q:If so, where will i have to go to get it?
That's was my problem too. I let my garage to use it and buy another brand.I think you have to re-install it.Maybe it was corrupted.
Q:I got two hard drives. The cable connecting the hard drive has 2 connectors, does it matter which connector goes to the master drive and which goes to the slave drive? same question regarding the power supply. 2 connectors on the power cable, the order matters?
it doesn't matter which power cable you use for your hard drive. however, the hdd cable is different story. I am assuming you have EIDE cable. If you just have one hard drive connecting, then it doesn't matter which connector you use. If you have 2 hard drive connecting with one cable, either you have to change the jumper setting so one HDD will be master other one will be slave. Another way is to change the jumper setting on both HDD to cable select; in this case, the hard drive connected at the end connector will be master and the hard drive connected to middle connector will be slave.
Q:(above question) and can i use a fender strat guitar with this amp instead of a bass? and are there things i should know before using this amp?
The power cable thing could potentially be a serious problem, since it seems the ground wire is lifted or missing. I'd definitely check this with a knowledgeable person if I were you. It may be as simple as changing to another AC power plug and connect the earth/ground wire. Do you need an extra preamp? No. Any combo amp have two amp stages built in: pre- and power amp. Adding and extra preamp is highly unlikely make the sound better. You will probably just add hiss and noise. This is not a great amp for playing guitar, although you won't ruin anything by doing it. Just plug yoiur guitar in and see if you like the sound or not.
Q:So this is on my brothers christmas list and I can't find one anywhere. I'm assuming that computers don't have the juice to power a 1TB external without a power source, especially since he needs this for a laptop. He just wants it USB powered, btw.If anyone can find one for me that would be great, because I can't seem to...Thanks!
Something okorder
Q:the contant power cables go to my car alarm, led lights, siren, power locks, power windows, and alarm bypass... they are very small thin awg wires... the ignition and constant power cables under ignition housing are alot thicker... is this possible with no problems?
I wouldn't tap into any wires where your alarm is.. If you have any issue, it could arm your alarm, and you might not be able to start your car, until the wiring was fixed...

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords