• Solar Inverter Off-Grid Type Solartec D 6000/8000 System 1
  • Solar Inverter Off-Grid Type Solartec D 6000/8000 System 2
Solar Inverter Off-Grid Type Solartec D 6000/8000

Solar Inverter Off-Grid Type Solartec D 6000/8000

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
10 unit
Supply Capability:
1000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Product Description:

The photovoltaic grid-connected inverter series of Solartec D 6 - 8 kW are applicable to all types of commercial rooftop projects or grid-connected power plant systems. The nominal output powers of this series are 6 kW and 8 kW respectively.


This series of inverters has 2 string MPP trackers and three level technology. These features ensure the high utilization rate of grid and maximize the system efficiency. The new technology of this series supports the adjustable power factor and grid monitoring, complies to German BDEW medium voltage guidelines and reaches European and Australian certification standards .

Efficient

Maximum efficiency 98 %

Flexible tracking with two MPP trackers

Reliable

Integrated DC switch

Three phase grid connection

Reliability and long life ensured by film capacitors

Flexible

DC input voltage up to 1,000 V

Reactive power supply

For indoor and outdoor installation

Communicative

RS232 / RS485 interfaces as standard

 

 

Product Datasheet:

 

Solartec D 6000

Solartec D 8000

Input Data

Max. DC Power

6350 W

8250 W

Max. DC Voltage

1000 V

1000 V

System Start-up Voltage

250 V

250 V

Full Load Voltage Range MPPT

250 V - 800 V

250 V - 800 V

Max. Input Current

2 × 16A

2 × 16A

Nominal DC Voltage

650 V

650 V

Number of MPP Trackers

2

2

Strings of each MPPT

A : 1, B : 1

A : 1, B : 1

Output Data

Nominal AC Output

6000 W

8000 W

THD of AC Current

< 3.0 %

< 3.0 %

Nominal Grid Voltage Range

230 V - 400 V (3/N/PE)

230 V - 400 V (3/N/PE)

Nominal Grid Frequency

50 Hz

50 Hz

Adjustable Displacement Factor

0.9 overexcited...0.9 underexcited

0.9 overexcited...0.9 underexcited

Max. Output Current

10 A

13 A

Efficiency

 

Solar Inverter Off-Grid Type Solartec D 6000/8000

Product Advantages:

  1. Powered by DC current

  2. Can used out of doors

  3. High effiency and low noise

 

 

FAQ

  1. What is your payment terms?

    We accept T/T payment, normally we need 20% T/T in advance, 80% payed before shipment.

  2. What is your packing system?

    We put the sistem in the wooden box.

  3. Can you do OEM service?

    Yes we can, but we need to do it with a certain order quantity.

 

 

Q:How does a solar inverter impact the payback period of a solar system?
A solar inverter plays a crucial role in converting the direct current (DC) electricity generated by solar panels into usable alternating current (AC) electricity for household or grid consumption. The efficiency and performance of the solar inverter directly impact the overall energy production of the solar system. A higher quality and more efficient solar inverter can maximize the electricity generation, reducing the payback period of the solar system. Conversely, a low-quality or inefficient solar inverter may result in lower energy output, potentially extending the payback period of the solar system.
Q:How does a solar inverter handle variations in ambient temperature?
A solar inverter handles variations in ambient temperature by incorporating temperature compensation mechanisms. These mechanisms allow the inverter to adjust its operation and optimize performance based on the temperature conditions. By monitoring the temperature, the inverter can regulate voltage levels, adjust power outputs, and protect itself from overheating. This ensures that the inverter operates efficiently and reliably under different ambient temperature conditions.
Q:What is the role of power ramp rate control in a solar inverter?
The role of power ramp rate control in a solar inverter is to regulate the rate at which the power output of the solar panels increases or decreases. This control feature helps to ensure a smooth and gradual transition in power generation, thereby preventing sudden fluctuations and potential grid instability. By managing the rate at which power is introduced to the grid, power ramp rate control helps to maintain the stability and reliability of the overall electrical system.
Q:How does the weight of a solar inverter affect its installation process?
The weight of a solar inverter can affect its installation process as it determines the level of effort and resources required to mount and secure the inverter. Heavier inverters may require additional structural support, more manpower, and specialized equipment during installation.
Q:How does a solar inverter handle ground fault protection?
A solar inverter handles ground fault protection by continuously monitoring the flow of current between the solar panels and the ground. If it detects any abnormal current leakage, indicating a ground fault, it quickly shuts down the system to prevent any safety hazards or damage to the equipment.
Q:Can a solar inverter be used with a solar-powered food dehydrator?
Yes, a solar inverter can be used with a solar-powered food dehydrator. A solar inverter is responsible for converting the direct current (DC) generated by solar panels into alternating current (AC) that is suitable for powering household appliances. Since a food dehydrator operates on AC power, using a solar inverter allows the solar energy captured by the panels to be utilized effectively in powering the dehydrator.
Q:What is the role of a fault detection system in a solar inverter?
The role of a fault detection system in a solar inverter is to monitor the performance and integrity of the inverter and solar panel system. It detects and identifies any abnormalities or malfunctions within the system, such as voltage fluctuations, short circuits, or overheating. By promptly identifying and reporting faults, the system helps ensure the safe and efficient operation of the solar inverter, preventing potential damage and maximizing the overall energy generation.
Q:What is the maximum voltage input for a solar inverter?
The maximum voltage input for a solar inverter typically depends on the specific model and manufacturer. However, in general, it ranges from around 600 to 1000 volts, with some higher-end models able to handle higher voltages.
Q:What is the role of a maximum power point tracker in a solar inverter?
The role of a maximum power point tracker (MPPT) in a solar inverter is to optimize the energy harvesting efficiency of the solar panels. It continuously monitors the output voltage and current of the panels and adjusts the operating point to ensure maximum power extraction from the panels. By tracking the maximum power point, the MPPT allows the solar inverter to generate the highest possible energy output from the available sunlight, thus maximizing the overall system performance.
Q:Can a solar inverter be used with a solar-powered electric vehicle charging station?
Yes, a solar inverter can be used with a solar-powered electric vehicle charging station. The solar inverter helps convert the direct current (DC) power produced by the solar panels into alternating current (AC) power that can be used to charge electric vehicles. This allows for efficient and sustainable charging of electric vehicles using solar energy.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches