• YHZKB-2XZ series rotary vane vacuum pump System 1
YHZKB-2XZ series rotary vane vacuum pump

YHZKB-2XZ series rotary vane vacuum pump

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing
2XZ-BSeries
1. High speed, Iow volume, light weight, equipped with noise reducer, low noise, less shake. Pump stop and oil returnprevention is equipped, so that pupm oil is prevented to get back to the pump once pump stopped working, which makes it easy to restart.2. Gas valve is installed in order to separate the vapor from the gas, when pumping gas mixed with vapor. The valve prohibited the entrance of the vapor, ensured the purity and prolonged the use of the pump oil.3. Vent is applied with oil fog capture mchine to eliminate oil fog when discharge the gas. Ol collecting equipment is installed around the oil sal, in order to preven oil leaking, and entironment pollution.Motor power:0.37~1.5KW,extract capacity2~15L/S,Limit vacuum:2×10-2Pa。


■List of performance

Unit
2XZ-2B
2XZ-4B
2XZ-6B
2XZ-8B
2XZ-15B
off-gas quick result
L/S
2
4
6
8
15
limited
pressure
Branch pressure
(close gas)
Pa
2×10-2
2×10-2
2×10-2
2×10-2
2×10-2
General pressure
(close gas)
Pa
6×10-1
6×10-1
6×10-1
6×10-1
6×10-1
Branch pressure
(open gas)
Pa
6×10-1
6×10-1
6×10-1
6×10-1
6×10-1
General pressuer
(open gas)
Pa
9×10-1
9×10-1
9×10-1
9×10-1
9×10-1
Noise (close gas)
dB(A)
60
60
65
70
70
Working temperature
80
80
80
85
85
electric
machine
Voltage
V
380/220
380/220
380/220
220/380
220/380
Power
Kw
0.37
0.55
0.75
1.1
1.5
Rotate speed
r/min
1420
1420
1420
1400
1400
Weight
Kg
23
30
40
70
90
Shape&size (L×W×H)
mm
560×190×230
570×190×230
570×190×230
600×230×420
690×230×420


Q:Double floor sewage pump circuit diagram of a small problem
Question 3 when the water level is low, when the 1KA is connected, the pump will run depending on where your SS selector switch is located. Its left and right position, running pump and standby pump definition is different, left position is 1#, running 2# standby, right position is 2# running, 1# standby. Only inIn case the high level switch 2KA is connected, the standby pump may work at the same time.
Q:Advantages and disadvantages of centrifugal pumps?
Centrifugal pump; advantages and disadvantages:(1) advantages:The structure of the pump is simple and compact, and the centrifugal pump has small area, light weight, little material consumption and high cost for the foundation. Therefore, the cost of manufacturing and installation is less.For high speed operation, the 2 pole or 4 pole motor can be directly connected. The drive structure is simple and easy to install.
Q:What should be used to pay attention to the use of mechanical pumps?
Overall: large pump should first do a good job of the foundation, to find a good whole, fixed, and motor, pump should be added good oil, the first test of the motor, and then conjoined test
Q:A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
Such as a large pressure of about 10m or about 0.1MPa} because the most unfavorable point fire hydrant requires more than 0.07MPa (7m) and 0.5MPa (50m) is not greater than the pressure, so unless the pump is located in the 50m Valley is still lower than the garage, or add to the valve (or the use of fire hydrant decompression) otherwise, it is 120m lift pump
Q:Troubleshooting of diaphragm pump
In the application of the pump, these conditions are likely to encounter. Each situation can be divided into several possible reasons. This guide lists the causes of failures and gives appropriate corrective maintenance measures. The meaning of all the specific terms in the guide is listed later.Air valves - copper or stainless steel valves are bolted to the center of the pump by four bolts.The piston aluminum cylinder is enclosed in the air valve to control the gas flow.Cavitation - because the pump inlet for the amount of fluid to reduce or lack, the pump discharge is less than the amount of quantitative. In fact, the fluid chamber is full of fluid before it is discharged.Static pressure drop - the inlet pressure from the pump centerline to the free point - the inlet is measured in pounds, including the specific gravity and velocity of the fluid.
Q:The function of centrifugal pump
The basic structure of the centrifugal pump is composed of six parts, namely: impeller, pump body, pump shaft, bearing, sealing ring, stuffing box.1, the impeller is the core part of the centrifugal pump, it is high speed, large output, the impeller blade and play a major role in the impeller before assembly, through the static equilibrium experiment. The inside and outside surfaces of the impeller are required to be smooth, so as to reduce the friction loss of the water flow.
Q:Why does the centrifugal pump start with a closed valve and the axial pump starts with an opening valve?
The power of axial flow pump decreases with the increase of flow rate, and it is a steep curve, so the centrifugal pump starts with an open valve.
Q:Brief description of centrifugal pump on / off operation
First, the preparation before the start(1) carefully check the inlet and outlet pipe line, valve, flange and pressure gauge joint of the pump, whether the installation is safe, comply with the requirements, whether the flow is correct, whether the anchor bolt and other connecting parts are loose or not.(2) add lubricating oil to the bearing case, and the oil level is 2/3 of the gauge of the bearing box.
Q:Why should the pump be closed when the centrifugal pump is started?
Therefore to close the outlet valve, the pump during starting output water, the minimum pump power, when the pump reaches the rated speed, slowly open the outlet valve, gradually increase the flow of water, the motor current is gradually increased to the rated current.
Q:What is the liquid pump? What are their categories? What are their strengths and weaknesses?
The liquid pump can be filled with oil, water and chemical medium. The gas drive range of the liquid pump is 1 to 10bar (14.5-145psi). The bottom piston is controlled by a two position four pass pilot valve.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords