• Hot water pump System 1
Hot water pump

Hot water pump

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing
  • . Technical Parameters

    Q: 150~11600 m3/h  Head: 15~200m


    2. Structure:

    Single-stage double-suction centrifugal pump



    Seal

    Bearing

    Lubrication

    Scope of delivery

    floating ring seal

    rolling bearing and ball bearing

    Lubrication thin oil


    pump, motor, coupling, base plate



    View from motor end the rotation direction is counter-clockwise direction.


    Please notify materials of major components in your order. If you have any question, please contact to us without hesitation.

  • Construction: The pump is horizontally installed. The inlet and outlet are under the split surface and in the perpendicular direction with pump central shaft-line, during the course during the course of installation, you needn't to remove the motor and the pipes.
    Type SLA is vertically installed the inlet and outlet at a same center line and the case and cover are in the perpendicular direction.
    Bearing: Both end of the pump are rolling bearings (type 24SA_18, 16SA_90 could use the sleeve bearings)to support the rotor, the lubrication oil is dilute oil or grease.
    Materials of tolerance: The material s of tolerance is cast iron or it can be changed into cast steel and bronze, but it should be signed in the order.

  • No file download!

    Order
    In addition to Content, other items are importing!
    Product:
    Number:
    Linkman:
    Tel:
    addRess:
    Content:


Q:Rules for operation of centrifugal pumps
Working principle and process flowWorking principle: when the drive motor with high-speed rotating impeller, full of fluid in the pump body under the action of centrifugal force, was thrown from the impeller center to the outer edge of the impeller, in this process, the fluid energy, improve the pressure can, at the same time also increases the energy flow rate increase. The liquid from entering the pump impeller shell, the liquid flow gradually widened, the liquid velocity decreased gradually, which will be part of the kinetic energy into pressure energy, which further improves the static pressure of liquid, and liquid with high pressure in pressure pipeline. When the liquid from the leaves out when the impeller center creates pressure and low pressure than the out plane is big, under pressure drive, liquid is continuously from the center of the impeller suction, with the pressure of continuous discharge.
Q:If the calculation of the required pump flow is 45, lift 110, and the actual pump flow 100, head 125, what will happen in operation? Can I use it properly?
Centrifugal pumps are too big to measure.There is a reason why the centrifugal pump does not measure up:The pump inlet pipe blockage, leakage.The pump inlet pressure is too low.
Q:Bolus dosage of infusion pumpWhat is the purpose of the pill dose control in the special safety standard for infusion pumps? If the risk is not properly controlled, what is the degree of risk? And how can the open infusion pump be used in this regard?
Four) release bolus dosage method can use automatic release and manual release two ways, the key is to alarm after the infusion must be stopped(five) any kind of pill dose release are not restricted to replace the pill. The total dose limit for in pipe blockage after pill agglomeration process will remove blocking accident, this time will be the rapid infusion of pill dose concentration into the patient's blood, if the total dose pill does not get test and limit, rapid infusion of this accident it may have unimaginable consequences.(six) supplies open type infusion pump overflow on the domestic market for pill characteristic parameters of consumables simply without testing and limitation. Therefore, the risk of accidental pill has become one of the residual risk of open type infusion pump supplies the most deadly.
Q:You'd better point out the details.... There are 2 best ways of experience and formulaCan you say a simple point, such as multi-stage pump, when the pump is higher than the motor, 30 wire is the next mouth how to do?
Alignment methods and requirements:1, check two feeler dial gauge or flange coupling the parallelism, usually with clearance between the both ends of the side instead of difference, in the circumferential direction every 900 measure, the maximum and minimum gap gap difference (Ab) less than or equal to 0.3 mm.2, the coupling flanges outside the park up and down, left and right four position to check whether they are in the same line, C less than or equal to 0.1 mm.When looking for a positive C, it will affect (a - b), finding the right (a - b) will affect the C, to balance each other. It's easier for an unskilled comrade to find C (a - b) first, and then find a positive one. Through the adjustment of the motor at the foot of the gasket thickness (Ab) and meet the requirements of C.Check the inlet and outlet piping before alignment. Make sure the weight of the inlet and outlet pipe does not exert force or torque on the pump. When looking for, should also pay attention to eliminate the pump rotor movement, so as to avoid the end gap error. If checked after the pump is working, it should be carried out under cold condition.It is important to draw attention to the fact that the pump set of the complete set of factory is only rough looking (checked with a ruler) when it is shipped. It may cause displacement when it is transported.
Q:Significance of water pump model ISO50-160
Meaning of water pump model ISO50-160: ISO- stands for international standard code (IS). 50- indicates that the inlet diameter of the pump is 50 mm (the complete model IS50-32-160 32- indicates that the outlet diameter of the pump is 32 mm). 160- represents impeller diameter.
Q:What is the displacement of the pump? Flow? What is the volume efficiency and mechanical efficiency of the pump?
Mechanical efficiency: the ratio of theoretical torque to actual torque of the pump.
Q:Harm of air pump and pump
Minimum starting current when centrifugal pump of such a small impact on the grid but long closed operation will make the liquid in the pump to the pump overheating temperature is too high will lead to the problem of the seal to a certain temperature will cause deterioration of oil bearing bearing caused by excessive wear and even bite dead
Q:Water pump can not be pumped out, how to maintain water?
The pipe leaks or leaks:The nut may not pinch well when it is installed. If the leakage is not serious, it can be coated with cement or mixed with asphalt oil in the places where the gas leaks or leaks. Temporary repairs can be done with wet mud or soft soap. If the leakage at the joint, you can tighten the nut by hand. The leak is critical and must be re assembled.
Q:What's the pump? Where can I use it?
Pump can usually be divided into three types of displacement pumps, power pumps and other types of pumps according to the principle of operation. In addition to classification according to the working principle, it can be classified and named according to other methods.
Q:How long does the fine stone pump need maintenance? What should I pay attention to?
Check the line from the relief valve to the cylinder inlet to ensure that there is no external drainage or deformation due to impact and wear and that the connections are complete and fully tightened. - replace any damaged pipe immediately. - change the original settings strictly: all adjustments and calibrations can only be done by professionals. - no fucks hydraulic components, otherwise manufacturers on product warranties and liability shall not be responsible for. A warning because the hydraulic oil can reach very high temperature, there is the danger of burns, so open pipe fittings should take appropriate protective measures. Any replacement parts must conform to the level specified by the manufacturer. 8.2 check lubrication grease pump in oil at any time to ensure adequate and clean the lubrication pipeline joints without overflow phenomenon. Check the lubrication of the running parts at any time, and find the parts which lack oil, and check them immediately to prevent accidents. - check that the centralized lubrication system is effective daily. When the grease pump is empty, the grease added is often not easy to pump out because of the bubble. In this case, open the outlet of the pump, run the grease pump until the grease is re flowing, and then connect the pipe

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords