• Horizontal  Pump For Firefighting System 1
Horizontal  Pump For Firefighting

Horizontal Pump For Firefighting

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
5000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Description

Singlestage double suction,horizontal firefighting pump set is newly developed according to market needs.Its executive standard is GB6245《Fire pump》,and the most advanced hydraulic model is applied,combining with the characteristics of double suction pump.It is high efficient and energy-saving,reliable performance,easy to install and use.It is used to transport clean water or liquid with physical and chemical property similar to clean water.Max temperature of liquid can not exceed 80℃.

Applications

It has been widely used in fire fighting and living water supply of industry the residence buildings.

Parameter range

Inlet diameter:150-300mm(6"-12")

Capacity:30-200L/s

Head:0.3-2MPa

Rate of rotation:2980r/min、1450r/min

Power:2.2-160kW

Two seal types: stuffing seal or mechanical seal

Structural Characteristics

Both inlet and outlet of XBD-S type pump are below the pump’s axial central line.They are perpendicular with axial line and horizontally placed in the middle of pump casing.There is no need to remove inlet,discharge pipeline and electric motor(or some other motors).The pump rotates clockwise from the direction of the coupling.The pump which rotates anticlockwise can also be manufactured according to the requirements,but it should be specified when ordering.

  XBD-S type pump is mainly made up of pump casing(1),pump cover(2),impeller(3),shaft(4) and double suction seal ring(5),shaft sleeve(6) and bearing(15),etc.Except that the material for the bearing is first grade carbon steel,the remained are all made of cast steel(See the structural drawing of pump).

  Pump casing and pump cover compose an impeller’s working room.The installation vacuum gauge and pipeline bolt hole on the pressure gauge are designed for the inlet and outlet flange.After the static balance test on the impeller,it is fixed with the shaft sleeve and sleeve nuts on both sides.The axial location can be adjusted through the sleeve nut.The impeller’s axial force makes use of the symmetric layout of its vane to keep in balance.The rest little residual axial force is borne by the bearing at the shaft end.

  The pump is supported by two single-row radial ball bearings.The bearing is installed inside the bearing body at both sides of the pump casing,and lubricated with solid lubricant.The double suction seal ring is used to reduce the amount of leakage of water at the pump impeller.

  Pump is directly connected with the electric motor through elastic shaft coupling.(If the transmission with rubber belt must be applied,a support shall be mounted in addition.)

  The shaft seal adopts soft packing seal and mechanical seal.In order to cool down the lubricant seal chamber and also to prevent air from leaking into the pump,a water seal ring is mounted among the stuffing.While pump is running, slight amount of high pressure water passes through the concave groove on the centrally-split surface of pump cover into the packing chamber,which functions as water seal.



Q:Water pump spoon pipe for power plantWhich hero can tell me what is the water pump spoon tube ah? And its role
By adjusting the amount of oil entering into the hydraulic coupler, the torque of the hydraulic coupler can be controlled
Q:Does the control cabinet of the fire control pump need to be related to the fire control room?
Normal words are needed, but when you check and check, has anyone checked?
Q:What do you mean by the self coupling device on the pump?
Auto is an installation of the pump, which comprises a pedestal, self coupling frame, a guide rod and a guide rod support, the bottom fixed coupling frame, vertical installation of two guide rods can easily be brought down without installing the pump, the pump at the bottom of the pool, the outlet of the pump and the discharge tube can automatically lock, don't need to bolt connection, automatic coupling position, so as to achieve the effect of simple and convenient. When you need to repair, pump the pump up without jumping into the sink.
Q:What are the causes of pump shock?
3. the water pump set screws loose, adjust the concentric, fastening the foot4. pump into foreign body, open cover overhaul5. the flow is too large or too small, adjust the equipment to control the water output
Q:What is the name of the day pump and ground pump? Specific introduction
People often say "day pump" actually refers to the boom pump, it also has many other name, such as pump, boom pump, concrete pump, concrete pump truck, these words are "day pump".Ground pump, in fact, refers to the pump drag pump. Therefore, to understand the difference between day pump and ground pump is to understand the difference between the boom pump and the tow pump
Q:Because the water pressure of the booster pump is not enough, it can not work automatically. It can only be operated by hand. It is inconvenient to use.
If the water pressure is not enough, the pump can not start, then it must be wrong. Because if the water pressure is not enough, the pump should be running automatically. It's just because the water pressure is not enough.
Q:Water pump can not be pumped out, how to maintain water?
Severe vibration of water pumpIt is possible that the rotor is unbalanced, or the coupling is not good, the bearing is worn and bent, and some parts may be loosened and broken. They can be adjusted, repaired, strengthened or replaced separately.
Q:If you use an ordinary 15W submersible pump, put it in the tank, if the leakage, the fish will hang it?
Submersible pump even if it really leakage, it will not cause the fish electric shock. The so-called leakage is the submersible pump wire or shell broken, live parts and water contact, the most extreme test is a fire line directly into the fish tank
Q:Is the centrifugal pump large or small?
Centrifugal pump, the smaller the better the cavitation.1, centrifugal pump cavitation less, anti cavitation performance is better, the pump cavitation is called the necessary cavitation margin or pump inlet dynamic pressure drop, the smaller the better. Generally speaking, the pump cavitation is the need for cavitation, the pump inlet pipe said effective cavitation margin, that is, the device cavitation margin. For a given pump, at a given speed and flow rate required NPSH is called pump necessary NPSH, also called NPSH, is required to achieve the performance parameters of the pump cavitation, the internal flow and the centrifugal pump is composed of pump head itself, its physical meaning is that liquid drop in pump inlet pressure part degree, is to guarantee the pump cavitation does not occur, with surplus energy exceeds the vaporization pressure head at the inlet of the pump unit weight of liquid. The cavitation must be independent of the device parameters. It is only related to the parameters of the inlet of the pump. These parameters are determined by the geometric parameters at a given speed and flow.
Q:What does "dual purpose" of water pump mean? Please expert advice
1, if the water pump in the process of a strong vibration, then must stop to check what is the cause, otherwise it will cause damage to the water pump.3, when the pump valve Water Leakage, some people will fill with dry soil to the water pump inlet pipe, the water washed in the end valve, this is indeed undesirable. Because when the dry soil into the inlet pipe, when the pump started to work, these dry soil will enter the pump, then it will damage the pump impeller and bearings, thus shortening the service life of the pump. When the valve Water Leakage must take to repair, if it is serious that need to replace the new.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products