120kva/96kw super silent cummins generator with CE approved (GDC120*S)

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
300 unit/month
Inquire Now Customer Service

Contact us by

(1) WeChat
(2) Whatsapp: +8617190086776

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Item specifice:

power range: 8-1650kva certificate: CE,ISO9001 noise control for silent: 65-75db in 7metres
protection class: IP23 test loading: 25%,50%,75%,100%,110% use: land use
insulation class: H fuel tank capacity: 8hours or by your request

Product Description:

120kva/96kw  super silent cummins generator with CE approved (GDC120*S)

120kva/96kw  super silent cummins generator with CE approved (GDC120*S)

120kva/96kw  super silent cummins generator with CE approved (GDC120*S)

120kva/96kw  super silent cummins generator with CE approved (GDC120*S)



GODLIKE POWER Diesel Generator Set Advantage:
·  50Hz@1500rpm or 60Hz@1800rpm all are available
· AVR delivers non fluctuating power
· Panel type digital control panel/manual control 
· 12 Volt / 24 Volt electric starter ensures easy starting
· Low oil pressure shut down system
· Low fuel cut out protection
· Low water cut out engine protection
.High water temperature cut out engine protection 
· Enclosed structure ensures quieter operation
· Alternator (Dynamo) excitation mode brushless self excitation
· Three-phase output meets differing requirements
· Four Cylinder, four stroke, water cooled diesel engine
· 8 hours running @ full load on a single tank of fuel
· Dual access doors for easy maintenance
· Optional automatic or manual transfer switches available
· ATS ( auto transfer switch for city power and generator power ) / AMF (auto mains failure) /parallel running for option
· Weatherproof and soundproof, enclosure high grade steel protected by powder coat painting and incorporate internally mounted exhaust silencers
· Noise Level (65-75dBA @ 7m)
· All ratings are at sea level

After-sales Service:
1 year or 1000 continuously running hours subject to the earlier one. 
Our Diesel Generator Set Production Range is as follows:

* Engine (motor) for Choice 

1. Cummins  :23kVA - 1500kVA
2. Perkins    :9kVA - 2250kVA
3. Lovol (China): 30kVA - 138kVA
6. Yangdong (China) :11kVA - 63kVA
7. Weichai (China) 30kVA - 188kVA
8. XiChai (China) :18kva-375kva
9.Yanmar(Japan):6kva-58kva


* Canopy for Choice 
1. Silent type (75- 80 dB(A) at 7 meters)
2. Super Silent type (65-70 dB(A) at 7 meters )
3. Open type 
4. Trailer type (mobile) 
5. Container Type 
6. Parallel System 

Item
No
Genset ModelPower Out Put
400V/50HZ/1500RPM/3P/0.8 ( Y )
Cummins
Engine
Model
Stamford
Alternator
Model
Prime 40  degree
1GDC4334KW43KVA4BT3.9G1/36KWUCI224C
2GDC4334KW43KVA4BT3.9G2/36KWUCI224C
3GDC5040KW50KVA4BTA3.9G2/50KWUCI224D
4GDC6048KW60KVA4BTA3.9G2/50KWUCI224E
5GDC10080KW100KVA 6BT5.9G1/92KWUCI274C
6GDC10080KW100KVA 6BT5.9G2/92KWUCI274C
7GDC12096KW120KVA 6BTA5.9G2/106KWUCI274D
8GDC135108KW135KVA 6BTAA5.9G2 /120KWUCI274E
9GDC160128KW160KVA 6CTA8.3G2/163KWUCI274F
10GDC180144KW180KVA 6CTA8.3G2/163KWUCI274G
11GDC200160KW200KVA6CTAA8.3G2/183KWUCI274H
12GDC225180KW225KVA6LTAA8.9G2/220KWUCI274J
13GDC250200KW250KVA6LTAA8.9G2/220KWUCI274K
14GDC250200KW250KVANT855-GA/231KWUCI274K
15GDC250200KW250KVAMTA11-G2A/234KWUCI274K
16GDC300240KW300KVANTA855-G1A /261KWHCI444D
17GDC300240KW300KVANTA855-G1B/284KWHCI444D
18GDC313250KW313KVANTA855-G1B/284KWHCI444ES
19GDC313250KW313KVAMTAA11-G3 /282KWHCI444ES
20GDC325260KW325KVANTA855-G1B/284KWHCI444ES
21GDC350280KW350KVANTA855-G2A/313KW HCI444E
22GDC350280KW350KVANTA855-G4/317KWHCI444E
23GDC375300KW375KVANTAA855-G7/343KWHCI444FS
24GDC375300KW375KVAKTA19-G2 /336KWHCI444FS
25GDC400320KW400KVANTAA855-G7A/407KWHCI444F
26GDC450360KW450KVAKTA19-G3/403KWHCI544C
27GDC500400KW500KVAKTA19-G3A/448KWHCI544C
28GDC500400KW500KVAKTA19-G4 /448KWHCI544C
29GDC550440KW550KVAKTAA19-G5 /470KWHCI544D
30GDC600480KW600KVAKTAA19-G6/520KWHCI544E
31GDC600480KW600KVAKTA19-G8/575KWHCI544E
32GDC625500KW625KVAKTAA19-G6A /610KWHCI544FS
33GDC625500KW625KVAKT38-G/560KWHCI544FS
34GDC750600KW750KVA KTA38-G2/664KWLVI634B
35GDC800640KW800KVA KTA38-G2B/711KWLVI634C
36GDC900720KW900KVA KTA38-G2A/813KWLVI634D
37GDC1000800KW1000KVA KTA38-G5/880KWLVI634E
38GDC1125900KW1125KVA KTA38-G9/1089KWLVI634F
39GDC12501000KW1250KVAKTA50-G3/1097KWLVI634G
40GDC13751100KW1375KVAKTA50-G8/1200KWPI734B
41GDC15001200KW1500KVA KTA50-GS8/1287KWPI734C
Item
No
Genset ModelPower Out Put
400V/50HZ/1500RPM/3P/0.8 ( Y )
Cummins
Engine
Model
Godlike
Alternator
Model
Prime 40degree
1GDC2318KW23KVA4B3.9G1/24KWJDG 184E
2GDC2318KW23KVA4B3.9G2/24KWJDG 184E
3GDC2822KW28KVA4B3.9G1/24KWJDG 184F
4GDC2822KW28KVA4B3.9G2/24KWJDG 184F
5GDC3125KW31KVA4BT3.9G1/36KWJDG 184G
6GDC3125KW31KVA4BT3.9G2/36KWJDG 184G
7GDC4032KW40KVA4BT3.9G1/36KWJDG224C
8GDC4032KW40KVA4BT3.9G2/36KWJDG 224C
9GDC5040KW50KVA4BTA3.9G2/50KWJDG 224D
10GDC5645KW56KVA4BTA3.9G2/50KWJDG 224ES
11GDC6048KW60KVA4BTA3.9G2/50KWJDG 224E
12GDC10080KW100KVA 6BT5.9G1/92KWJDG 274C
13GDC10080KW100KVA 6BT5.9G2/90KWJDG 274C
14GDC12096KW120KVA 6BTA5.9G2/106KWJDG 274DS
15GDC135108KW135KVA 6BTAA5.9G2 /120KWJDG 274ES
16GDC160128KW160KVA 6CTA8.3G2/163KWJDG 274F
17GDC180144KW180KVA 6CTA8.3G2/163KWJDG 274G
18GDC200160KW200KVA6CTAA8.3G2/183KWJDG 274H
19GDC225180KW225KVA6LTAA8.9G2/220KWJDG 274J
20GDC250200KW250KVA6LTAA8.9G2/220KWJDG 274K
21GDC250200KW250KVANT855-GA/231KWJDG274K
22GDC250200KW250KVAMTA11-G2A/234KWJDG274K
23GDC275220KW275KVANTA855-G1A/261KWJDG 314DS
24GDC300240KW300KVANTA855-G1A/261KWJDG 314D
25GDC313250KW313KVANTA855-G1B/284KWJDG 314ESS
26GDC313250KW313KVANTA855-G1B/284KWJDG 314ESS
27GDC313250KW313KVAMTAA11-G3 /282KWJDG 314ESS
28GDC325260KW325KVANTA855-G1B/284KWJDG 314ES
29GDC350280KW350KVANTA855-G2A/313KWJDG 314E
30GDC350280KW350KVANTA855-G4/317KWJDG 314E
31GDC375300KW375KVANTAA855-G7/343KWJDG 314FS
32GDC375300KW375KVAKTA19-G2 /336KWJDG 314FS
33GDC400320KW400KVANTAA855-G7A/407KWJDG 314F
34GDC450360KW450KVAKTA19-G3 /403KWJDG 354C
35GDC500400KW500KVAKTA19-G3A/448KWJDG 354D
36GDC500400KW500KVAKTA19-G4 /448KWJDG 354D
37GDC550440KW550KVAKTAA19-G5 /470KWJDG 354ES
38GDC575460KW575KVAKTAA19-G6/520KWJDG 354E
39GDC600480KW600KVAKTA19-G8/575KWJDG 354E
40GDC625500KW625KVAKTAA19-G6A /610KWJDG 354FS
41GDC625500KW625KVAKT38-G/560KWJDG 354FS
42GDC725580KW725KVA KT38-GA/711KWJDG 354G
43GDC750600KW750KVA KTA38-G2/664KWJDG 404B
44GDC800640KW800KVA KTA38-G2B/711KWJDG 404C
45GDC900720KW900KVA KTA38-G2A/813KWJDG 404D
46GDC1000800KW1000KVA KTA38-G5/880KWJDG 404E
47GDC1125900KW1125KVA KTA38-G9/1089KWJDG 404F
48GDC12501000KW1250KVAKTA50-G3/1097KWJDG 4



Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Whats the best Fuel economy (in mpg) you can get from a Diesel Electric car ?
A friend is getting well over 100MPG. But his journey is just about optimum for the car. Plugs in at both ends.
Q:Pros and cons of Air cooled Engine Vs Liquid cooled Engine in Diesel Generators of Higher Capacity?
At 20 KVA I'm thinking the air cooled set is using a Deutz, Want some advice? Avoid it like the plague! First off there noisy, and if you don't like replacing timing belts and head gaskets these are not the engines for you, As a heavy diesel equipment mechanic I seriously hate these engines, Lucky for me the outfit I work for now wont buy any piece of equipment equipped with a Deutz engine, So do yourself a favor and find a Genset with a Kubota or Isuzu in it, there not dumb enough to use an air cooled design, actually just buy a Multiquip and save yourself the headaches and repair bills.
Q:Question about Miller welder?
I don't remember, but the best thing to do is test it. Get some stock that's not worth anything, then do some test welds. Every machine is different, even if I knew the settings for a similar machine, that doesn't mean they would be right for you and your machine. I like to weld a little hotter and faster than most people, so I would be at a higher setting than you might like. Some people like to to colder and slower.
Q:Inherited a continuous 12.5 kw, 1800 rpm, 240 volt, single phase, 60 hz generator that requires 25 hp engine?
1) The 1800 RPM specification is the speed which will produce the 60 Hz output. This frequency is critical in some of your household electronics, maybe. If the speed is lower than 1800 RPM, the hertz will be lower. If speed is higher, the hertz will be higher. 2) The 25 HP driver is probably sufficient for your generator. A more powerful engine will not return the value for the extra cost of the larger driver. However, a larger driver will give you perhaps a better frequency control. 12.5 KW is (in theory) 12500 / 746 16.75 HP. I'm not sure what 'wet stacking' is. 3) .It will power most households. You may have some problem starting a large AC unit, if you have your electric clothes dryer, stove, oven and a larger lighting load on at the time it comes on. TexMav
Q:CAT diesel engine trouble.?
i think you might have a cracked block in this one ,that's one of the faults to those,the blocks was thin,and if not maintained right they would freeze up,the reading you got on the one cylinder may be the cylinder the problem is in also,i bought one of these at a salvage sale,and never did get it to run right,sold it to a friend,and when he tore it down it had a crack in the head and the block,you need to check yours out real good,you may have more problems than its worth,those are expensive to work on also,parts are very high,so be careful,and don't get in too deep on it,good luck with it.
Q:What should i know for building a little shack?
build shack
Q:how much voltage required for electric furnace in steel industry ?
Either could work. I don't know what he means.
Q:Diesel engine oil sludge?
Get a new one or get that one rebuilt.
Q:What size generator do I need for my single wide mobile home?
Add the power for each item, total watts for each and then double it for the size of the generator. I suspect at least a 10 kw unit. The heaters will use a lot of power next is the refrigerator and the deep freeze. The microwave will need to be inspected for size but usually they run on 15 amps at 120 volts and can draw down the output of the generator when they start. You will need a transfer switch and the proper installation and inspection of it to your power panel and possibly need to notify the local power company that you have the back up generator wired into the unit. Electric heat on a generator is not a good idea rather try to get a fossil fuel heat source that vent to the open air, this will allow a smaller generator to be used. I suggest you consult a local qualified professional electrician to do the work so they can properly size and install the package.
Q:Minimum load for a kohler generator?
500 kva is a big generator and I am guessing it is diesel. It is safe to run at 10% load however it is not good for the engine itself to make a practice of that. It can lead to lower cylinder temperatures and incomplete combustion over time. It is always better to run at or as close to max load as you can.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range