Ductile Iron Roughness

Hot Products

FAQ

What is plug welding gate valve?
Socket welding valve valve cover design in three forms. The first is forging steel bolt type valve cover, according to this design form design of the valve, the valve body and the valve cover bolt nut connection, spiral wound gasket 316 clamp flexible graphite manufacturing: seal. Customers have special requirements can be used when the metal ring connection. Second design form is the welded bonnet, according to this design form of the valve, the valve body and the valve cover with a threaded connection, welded seal. Customers have special requirements can be used when the third is connected through welding. Self sealing valve cover, according to this design form design of the valve, the valve body and valve cover with a threaded connection, pressure from the dense ring seal.The editing characteristics of 1 valve design and manufacture in accordance with API602 and ASME B16.34. tested according to API 598, marked by MSS-SP-25.2. full diameter or diameter shrinkage 3 rod bracket type 4 self centering sleeve type 5 pressure plate bolt connection, spiral wound gasket seal type valve cover nut connection, welded seal type valve cover and screw connect the internal pressure self tightening type valve cover 6 integral sealing seat 7 socket end with ASME B16.118. threaded end (NPT) with ANSI/ASME B1.20.19. valve can be transformed into the throttle type, needle type, ball type and type check
About fire valve is gate valve or butterfly valve problems?
Disease is generally in accordance with the design requirements, regardless of the butterfly or tie hair to meet the requirements, are two-way valve.
What are the standards for the execution of cast iron dark pole gate valves?
They are also standard in the production of cast iron dark rod gate valves:Design and manufacture: as per GB/T12234-89 regulationsLength of structure: as specified by GB/T12221-89Flange dimensions: as specified in JB79 GB/T9112-9131Inspection and test: as specified in JB/T9092-99 GB/T13927-92Drive mode: manual, electric, gear drive
Stainless steel gate valve DN150 200300 weight, who knows?
The weight of DN150/200/300 is 134/192/379kg. Of course, different manufacturers may vary in weight, but not much.It's not that heavy at all
Which is more expensive, bronze gate valve or brass gate valve?
But the obvious weakness of brass is its poor strength, relatively large volume, and its lack of corrosion resistance.
What else, P54140V, 170V? What do they mean?
P work pressureP54 temperature at 540 degrees of work pressureThe pressure at P54 100 is 540 at the temperature of 100barV valve for chromium molybdenum vanadium steelP54 pressure 140V temperature at 540 DEG C for 140bar valve for chromium molybdenum vanadium steelP54 pressure 170V temperature at 540 DEG C for 170bar valve for chromium molybdenum vanadium steelFrom the JB/T4018 "valve type model preparation method"The standard unit is MPa, but it is usually used in bar
The legend of gate valve and stop valve
Compared with the cut-off valve, the main advantage is that the flow resistance is small, the flow resistance coefficient of ordinary gate valve is about 0.08~0.12, while the ordinary cut-off valve resistance coefficient is about 3.5~4.5. Opening, closing force is small, the medium can flow in two directions. The disadvantage is that the structure is complex and the height is large. The sealing surface is easy to wear. The sealing surface of the valve must be forced to close the valve to achieve sealing, in the same caliber, work pressure and the same drive device, the drive valve torque is 2.5~3.5 times the gate valve. This point should be noticed when adjusting the torque control mechanism of the electric valve.The sealing surface of the stop valve contacts each other only when the valve is completely closed, and the relative sliding amount between the valve core and the sealing surface is very small, so that the wear of the sealing cover is very small. The sealing surface of the valve cover, mostly due to the spool and sealing surface before the debris, or because of the closed state is not tight, causing the medium of high-speed erosion caused by.
What kind of valve is gate valve? Is it different from the cut-off valve?
Gate valve is applied to the big diameter pipeline valve, the valve is generally used in small pipe diameter pipeline, their internal structure is different, the valve can not regulate the flow of water, the valve can be. If you want to understand in detail, it is recommended to take a sample of valve manufacturers to see the internal structure.