ZX Series Self-priming Centrifugal Pumps With High Quality

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
4000 set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Applications:

For water supply from wells or reservoirs. 

For domestic use, for civil and industrial applications. 
For garden use and irrigation.

HAIDEO deep well pump features :

1. 100% copper wire , automatic wiring 

2. Cold-rolled silicon steel sheet, with high-speed punching

3. 304 Stainless steel welding shaft

4. Over-current protector imported from Taiwan

5. C&U bearing ( best bearing of China)

6. No leakage with the high quality Mechanical seal

 

Operating condition

1.Water temperature is not more than 35°c

2.The PH value of water source is 6.5-8.0

3.Solid content in water not more than 0.01%; diameter of the bigest particle not more then 0.2mm;

4.Water coolant system

5.Motor rotation speed 2850rpm/min

6. Protective Device grade: IP68

7.Insulation Grade: F

8.Minimum water flow required to flow through motor:8cm/s

9.Maximum Start count per Hour :30 times

10. Can be installed vertically or horizontally

11.Flat water proof cable with separate groud wire.

 

Motor:

 

1.Rewindable motor

 

2.Single phase: 0.37-2.2 kw    220V( ±10%)-50Hz

 

3.Three Phase: 0.37 to 7.5kw  220/380V(±10%)-50Hz;  230/400V ( ±10%)- 50Hz


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What are the meanings of the vacuum pump, the front pump and the main pump?
The main pump can be understood as a booster pump, used to improve the vacuum mechanical pump with pumping quantity. As the roots pump, diffusion pumps, molecular pump. These can not use (too much pressure) so the need for mechanical pump drainage, the vacuum chamber is pumped into the rough vacuum, then the main pump starts to work.
Q:What do you mean by the self coupling device on the pump?
Overview of GAK self coupling device:The utility model relates to a GAK self coupling device, which is an automatic butt joint between a water outlet flange of a submersible electric pump and a water outlet pipe system.In the above additional coupling flange and the water outlet pipe seat inlet flange with a pair of wedge card, under the additional coupling flange and the water outlet pipe seat inlet flange and a pair of wedge cards in a wedge seat below the outlet pipe inlet flange card is made of elastic steel plate is fixed on the lower side of the seat pipe inlet flange. When the submersible pump water falling from above, Kaxianka additional coupling flange at the top of the wedge wedge and seat card outlet pipe above the inlet flange together, in the role of the dignity of the pump and submersible inclined wedge clamp, two flange will be put together in a pair of wedge under additional coupling flange and the water outlet pipe seat inlet flange the card will be in the elastic plate under the action of automatic card together. The utility model can solve the problem that a large amount of water leakage between the two flanges of the coupling is saved when the automatic installation and disassembly of the electric submersible pump is convenient, thereby saving energy.
Q:What is the cause of the damage of pump bearings?
Is the water pump motor overheating or damaged leaves overheating, resulting in overheating bearings, lubricating oil dry, excessive wear and tear guide system damage
Q:Why is the submersible pump tripped on an electrical switch?
Submersible pump cable or motor insulation is damaged.3) motor water solution
Q:The working principle of magnetic pump
Control of cooling fluid flowThe pump is running, you must use a small amount of liquid in the magnetic separation between the rotor and the casing annulus area and sliding friction bearings for flushing cooling. The cooling liquid flow pump design flow is usually 2%-3%, the annular area between the magnetic rotor and sleeve of eddy current generated because of high heat. When the cooling and lubrication the liquid is not enough or poor flushing holes to plug, will result in permanent magnet medium temperature is higher than the operating temperature of the inner magnetic rotor gradually loses magnetism, the magnetic actuator failure. When the medium is water or water-based liquid, can make the annulus area temperature maintained at 3-5 DEG C; when the medium or hydrocarbon oil that can make the annulus area temperature maintained at 5-8 degrees.
Q:Why adjust the centrifugal pump outlet valve can adjust the flow?
The centrifugal pump at a fixed speed, the head is fixed, adjust the outlet valve to adjust the diversion area
Q:What does "dual purpose" of water pump mean? Please expert advice
In order to ensure safe and continuous operation, three pumps usually need two units and run one standby.Precautions for using pumps1, if there is any small water pump failure, remember not to work. If the pump shaft packing end wear should be added in time, if you continue to use the water pump will leak. The direct effect of this is the increased energy consumption of the motor, which will damage the impeller.
Q:How to adjust the flow of piston pump?
For the swashplate valve controlled by the solenoid valve, the swashplate is in an angle with the cylinder body, so the plunger is reciprocating in the pump cylinder when the cylinder rotates. It goes from 0 degrees to 180 degrees, that is, to the upper plunger position, the plunger cylinder volume gradually increased
Q:What is the dry running protector of screw pump? What's the principle and function? Thank you
The utility model relates to a screw pump dry running protector, which is used for protecting the stator and the rotor of the screw pump from being transported by air
Q:How long does the fine stone pump need maintenance? What should I pay attention to?
- check that the centralized lubrication system is effective daily. When the grease pump is empty, the grease added is often not easy to pump out because of the bubble. In this case, open the outlet of the pump, run the grease pump until the grease is re

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range