ZHONGMEI XLPE lnsulated Power Cable YJV22 8.7/10KV 3X150

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
100000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1. Standard complied with:IEC60502-1997 Power cables with extruded insulation and their accessories for rated voltedes from 1KV up to 30KV;


2. Service performance

   (1)Operating temperature:Max.Permissible continuous operating temperature of conductors shall not exceed 90℃.

   (2)Short circuit temperature of conductor:Max.short circuit temperature shall not exceed 250℃(Max.sustaining period: not exceeding 5 sec.

3. Type and description:

Type

Description

YJV

Copper core cross-linked polyethylene insulated PVC sheathed power cable

YJLV

Aluminum core cross-linked polyethylene insulated PVC sheathed power cable

YJV22

Copper core cross-linked polyethylene insulated steel belt armored PVC sheathed power cable

YJLV22

Aluminum core cross-linked polyethylene insulated steel belt armored PVC sheathed power cable

4. Production scope:

Type

Number of cores

Rated voltage

0.6/1

1.8/3

3.6/6,6/6

6/10,8.7/10

8.7/1512/20

18/2026/35

Conductive wire core nominal cross-section mm2

YJV
YJLV

1

1.5800

10800

251200

251200

351200

501200

3

1.5300

10300

25300

25300

35300

-

4

4240

-

-

-

-

-

YJV
YJLV

1

2.51000

101000

251200

251200

351200

501200

3

2.5300

10300

20300

25300

35300

-

4

-

-

-

-

-

-

YJV22
YJLV22

-

-

-

-

-

-

-

3

4300

4300

25300

25300

35300

-

4

4240

4240

-

-

-

-

YJV23
YJLV23

-

-

-

-

-

-

-

3

4300

4300

25300

25300

35300

-

4

4240

4240

-

-

-

-


5. Structure, size and technical performance of 8.7/10kV XLPE cross-linked polyethylene insulated power cable:

Conductor

Inner shield thickness

Insulation Thickness

External shield thickness

Thickness of internal devices

Steel belt thickness

Thickness of external devices

Outer diameter of the cable

kv Test voltage

Maximum conductor resistance

Calculated weight of the cable kg / km

Cross-section

Outer diameter

3×25

6.2

0.8

4.5

1.0

1.4

1.0

2.6

53.2

22

0.727

3677

3×35

7.2

0.8

4.5

1.0

1.5

1.0

2.7

55.8

22

0.524

4169

3×50

8.4

0.8

4.5

1.0

1.5

1.0

2.8

58.6

22

0.387

4803

3×70

10.0

0.8

4.5

1.0

1.6

1.0

2.9

62.4

22

0.268

5674

3×95

11.5

0.8

4.5

1.0

1.7

1.0

3.1

66.3

22

0.193

6704

3×120

13.0

0.8

4.5

1.0

1.8

1.0

3.2

69.9

22

0.153

7708

3×150

14.5

0.8

4.5

1.0

1.8

1.0

3.4

73.5

22

0.124

8852

3×185

16.1

0.8

4.5

1.0

2.0

1.6

3.6

790

22

0.0991

11091

3×240

18.3

0.8

4.5

1.0

2.1

1.6

3.9

84.5

22

0.0754

12195

3×300

20.0

0.8

4.5

1.0

2.2

1.6

4.1

88.5

22

0.0601

15304

3×400

23.7

0.8

4.5

1.0

2.4

1.6

4.4

97.5

22

0.0470

190391

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Do i need a separate cable for power to connect my internal SATA drive to my laptop via its e-sata connection?
An okorder.com/ Yes you do need a separate power cable for any SATA devices, but that enclosure uses a small controller board to make a single cable design possible.
Q:question about sub amplifier power cable?
back interior the day whilst audio electronics became into evolving from monophonic sound to stereophonic sound, producers of stereo audio electronics precise the left channel enter for monophonic sound (in case you in elementary terms had one enter) and, if there became into no longer something plugged into the magnificent enter jack, the monophonic sound became into allotted to the two left and precise inputs. on condition that mono is fairly uncommon those days, i don't be conscious of if this continues to be everyday on stereo inputs (which includes powered subwoofers), yet you are able to try it. If it isn't the case (plugging it into the left enter purely is going interior the path of the left amplifier), no count in case you split the sign or no longer is in fact a wash. A subwoofer has 2 voice coils on the motive force, one powered by using the left enter and the different powered by using the magnificent enter. in case you purely have, say, the left enter plugged in, you're in elementary terms using the subwoofer with the left amplifier and voice coil. in case you split it, you're actually using the two voice coils. yet, the split itself cuts the sign point in 0.5. So, you have 0.5 as lots sign enter to each amplifier and the output quantity of the subwoofer heavily is not any distinctive than purely plugging in one enter. one element you are able to desire to do is to get a small, low-value stereo amp or receiver, plug the LFE output into one enter, set the amplifier mode to mono, and run the two line outputs to the subwoofer. that would desire to furnish you 2 complete line point inputs to the subwoofer from the only LFE cable.
Q:high effency double shielded transmission power cable?
What is your question? Does such a cable exist? Probably but you'll have to be more specific. High efficiency = low loss or low resistance per foot? Double shielded = is the shielding (in dB) critical? Transmission = What frequency, 60 Hz, 1 MHz, 100 MHz, ? Power = Watts, KW, MW Is weight or cost important?
Q:Can connecting a PoE powered cable cause a surge?
No, the PoE switch will initiate the connection with a low voltage signal to determine if the device at the other supports PoE or not. If not, it doesn't apply a current.
Q:I can not shut down my PC unless I remove the power cable. The power button doesn't work either. Any ideas?
replace your power button and reinstall your oprating system.
Q:Can I use a 7A power cable for a device with a 9A requirement without breaking either of them?
if your unit call for a 9 amp power cord and you drop it to 7 amps that would be a great lose of amps wires might over heat and cause a fire i won't do it myself its up to you and your safety if you want to do it
Q:Why cross bonding in power cable?
If so, the answer is: By tying multiple cables together, the current carrying capacity of the total cable is increased without having the total cost increase in proportion. In other words -- using the picture as an example -- tying 4 equal sized cables together increases the current carrying capacity by a factor of 4, but the cost of this multiple-wire cable is less than the cost of a larger single cable that would carry an equal amount of current. .
Q:How durable is a ps3 slim power cable?
they would last for years if you dont pull them or stomp on them... they are that good!
Q:Please help, need to know the name of a power cable.?
If you are in the UK, it is 13amp insulated, power cable with live, neutral and earth wires.
Q:what is the difference in applications between single and multicore power cables?
Multi-core power cables are useful any time you're carrying a circuit in and out of an appliance at the same location. Usually that's just 2 plus an optional ground. For electronic devices with specialized power requirements, there may be several power lines in the cable carrying different voltages. Single-core power cables are especially useful in high amperage appliances, such as welding equipment, and in DC automotive wiring in which the chassis serves as the ground. Thick cables for high amperage are hard enough to manage and wire without being bundled into a multi-core monster. It also makes sense to use single core cables with a ground chassis so that you only have to run one wire, and just complete the circuit to ground at the point of use. Single-core power cables can also be useful in serial or parallel wired appliances, or power supplies, such as a string of lights, or an array of batteries.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range