Product Description:

Cable Type :YJV

0.6/1KV power cable , XLPE insulation PVC sheath.

This product is suitable for electric power, metallurgy, petrochemical, construction and other infrastructure projects in line for the transmission and distribution system as well as the place which has a  high population density also needs high quality of flame retardant and fire-proof.

Operating temperature
Conductor Short circuit temperature
Bending radius:
Installation temperature:
Max. Permissible continuous operating temperature of
Conductors shall not exceed 90
Not exceeding 250 . Max. Sustaining period:
Not exceeding 5 seconds.
Bending radius of single core cable:

20D
Bending radius multi-core cable: 15D
D=Actual overall diameter of cable sample(mm)
The lowest temperature of installation is 0 .
Current ratings and basic parameters are calculated
under the following cable laying conditions and basic
ambient temperature.
method of laying Basic ambient temperature
In air 40
Directburial 25
Soil thermal resistivity
1.0 m/w
Layout of single core cables: In parallel
(Spacing side by side: 1D D=overall diameter)

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:W22 in the cable on behalf of what
Is the name of the vv22 it is armored copper core PVC insulated power cable V is PVC, VV said PVC insulated PVC sheathed, insulation and sheath is two different things, the jacket is the outermost layer of the cable, Insulation, mainly from the role of protection cable, the insulation layer is wrapped in the conductor outside the layer, mainly from the insulation. 22 means armored, armored between the sheath layer and the insulation between the strip, and its role is to strengthen the protection of the cable, at the same time, can prevent the mouse bite, can also be used as ground. The copper core is not shown in the letter in the model, because most cables are copper, so the copper cable basically takes its representation (indicated by T). On the contrary, if it is aluminum core cable, it will be added in the model L said aluminum core.
Q:How to effectively reduce the cost of car wiring harness?
5mm, that is 100: 76 followed by the proportion of push The height of the isosceles triangle at the time of the bend of the 200 high bridge is also suitable for the adjustment of the 90 ° bend; the use of the tool is cut off and the bending of the bridge is 90 ° Bridge elbow As for the length of the bridge to limit the restructuring of the elbow, as long as the use of junior high school learned by the simple mathematical knowledge of the calculation, any length distance can be controlled The use of mathematical methods simple calculation, a variety of angles, the length of the elbow can be made zuo
Q:How to connect the power cable pre-branch connector
Pre-branch cable should be fully cooled before the plate can be installed, otherwise it will cause the connection flat, affecting the appearance of packaging should pay attention to branch and trunk The end of the seal, to prevent the core of the water
Q:What is the installation specification for the cable tray bracket?
WDZ low smoke zero halogen flame retardant power cable. WDZN low smoke zero halogen flame retardant power transmission cable. W-halogen-free, D-low smoke, Z-flame retardant, N-refractory, YJ-XLPE insulated, V-PVC sheathed YJV-XLPE insulated PVC sheathed power cable. Model of the principle of omission: wire and cable products, copper is the main use of the conductor material, so the copper code T write, but bare wire and bare conductor products except. Bare wires and bare conductor products, power cables, electromagnetic wire products do not indicate a large class code, electrical equipment, wire and cable and communication cable category is not listed, but set out small class or series code. Item 7 is a special use of special occasions or additional special requirements of the mark, in the "-" after the alphabet letters. Sometimes in order to highlight the item, write this to the front. Such as ZR- (flame retardant), NH- (refractory), WDZ- (low smoke and halogen, enterprise standard), TH- (for hot and humid areas), FY- (anti-termite, enterprise standard).
Q:What recycled rubber is suitable for the production of wire and cable?
Need to choose according to specific circumstances. The main difference between single and multi-core is the flexibility of the wire. In fact the two do not exist which good question, but the use of the environment is not the same. Home decoration: First, the lighting line, can be used 1.5 single strand copper wire. . 2P (inclusive) or more of the air-conditioning, that is, hot water heater, Yuba must use 4 square double strand copper wire; Third, the wall buried the best choice for single wire copper wire, you can choose according to the need for 4 square Mm, 2.5 square millimeters, 1.5 square millimeters and other specifications (usually 2.5 square millimeters with the most). Fourth, the remaining lines, are using ordinary 2.5 pairs of copper wire can be.
Q:Power cable yjv22-10kv-3 * 50 what it means
This model is called copper core XLPE insulated PVC sheathed steel tape armored 3 core, each core conductor size 50mm. the cable voltage is 10KV cable. YJ: cross-linked polyethylene, cable insulation material for the chemical cross-linked polyethylene V: PVC, cable inner jacket material for the PVC jacket material first 2: plating Zinc steel strip, cable armor layer material for the galvanized steel strip Second 2: PVC, cable outer jacket material for the PVC sheathed material 10KV: that the use of the voltage of the cable waiting for you 10 kV 3 * 50 : That the cable is 3 core, each core conductor section 50mm2
Q:What are the lines that need to be set up for notebooks?
YJV cable is cross-linked polyethylene insulation, VV cable is PVC insulation, the former temperature level higher than the latter, such as the former conductor temperature can be 90 degrees, while the latter can only to 70 degrees!
Q:What is the warranty period for wire and cable?
General cable maintenance period is about 15 years, but to ensure that the normal use of the environment, such as the amount of temperature is below 70 degrees, but you are more than 70 working environment to use, of course, may not be used for a year. Therefore, the most important thing is to follow the instructions to use. Wire and cable recommended Ogilvy's.
Q:What is the difference between the control cable and the compensation cable?
. you want to achieve remote switch, right? In fact, from the host side of the original fixed switch button that cut the two lines, and then then you need to extend the extension cable you can, the super simple; . Internet cafes router, through the exchange (or hub) , Can achieve port expansion capabilities, you can access a lot of computers, but the Internet speed is limited by the router exit speed, that is the maximum speed will not exceed the router exit speed, and broadband providers will be on the server side of the uplink and downlink speed (That is, to provide customers with the speed) restrictions.
Q:Emergency power off after the computer can not open the machine, an open is a lot of words appear seconds limit, you can
There is a collection of. There is a direct connection, there are T then. Electric well trunking without cover, how can be connected

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range