Product Description:

2X-Series
The type two-stage oil-sealed mechanical pump system varactor vacuum pump, which has the characteristics of the exhaust directly to the atmosphere is suitable for electronics, refrigeration, electric light, chemical, medical, bottle lamps, packaging, dehydrating, drying and other industries. (But can not be used for extraction of oxygen is too high, there are explosive, corrosive to metal on the vacuum oil from the chemical reactions, as well as containing the particles, dust, gas, also can not serve as pumps and compressors use.Motor power:0.37~5.5KW,extract capacity:2~7L/S,Limit vacuum:6×10-1Pa。
■Performance Table
Type
off-gas quick result
(L/S)
limited pressure
(Pa)
mating power
(kw)
inner diameter of air inlet
(mm)
noise of vent
(dB)
total weight
(kg)
Shape&size(L×W×H)
(mm)
2X-70
70
6×10-2
5.5
80
≤86
333
91×66×70
2X-30
30
6×10-2
3
65
≤80
230
81×48×57
2X-15
15
6×10-2
2.2
40
≤78
202
79×53×54
2X-8
8
6×10-2
1.1
40
≤76
158
79×43×54
2X-4
4
6×10-2
0.55
25
≤75
66
56×34×40


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Attention should be paid to the use of pumps?
1, pump shaft packing completely worn, it is necessary to add in time, if you continue to use the water pump will leak. The direct effect of this is the increased energy consumption of the motor, which will damage the impeller. 2, the use of pumps in the course of a strong vibration, then must stop to check the reasons, or the same will cause damage to the water pump. 3 gear pump valve Water Leakage, some will use the soil into the water pump inlet tube, the water washed in the end valve, this is indeed undesirable. Because when the dry soil into the inlet pipe, when the pump started working, these dry soil will enter the pump, which will damage the pump impeller and bearings, which shorten the service life of the pump. When the valve Water Leakage must take to repair, if it is serious that it is necessary to replace the new. 4 after the use of pumps must pay attention to maintenance, for example, when the pump is exhausted, we should put the water pump who put clean, it is best to remove the water pipe, and then rinse with water. 5 water pump on the tape should also be written down, and then always flush, and then light out to dry, do not put the tape in the dark damp place. Water pump tape must not be stained with oil, not to tape coated with some sticky things.
Q:What is the minimum continuous flow of a pump?
The minimum continuous steady flow can be obtained by test and, in general, the pump supplier will indicate(2) minimum continuous heat limited flow (.API) provides minimum continuous heat limit flow, which means the minimum continuous flow that the pump can maintain and that its operation is not impaired by the temperature rise of the liquid being pumpedMinimum continuous heat limited flow can be calculatedIn the formula, the Pe amount of the fixed axis power is.KW;P pump medium density, kg / m3;
Q:What is double hydraulic pump?
Two hydraulic pumps installed on one shaft can be connected to increase output flow, and can also be connected to increase output pressure. See how the demand is. The system can change the mode of application at any time.
Q:How many square cables does the submersible pump for 7.5KW need?
I=P/ (1.732Ucos phi) =7.5/ (1.732X0.38X0.85) =13A (calculated according to three-phase city power, power factor 0.85).
Q:What's the difference between a centrifugal pump and a centrifugal pump? What are they used for?
Centrifugal pumps are used to transport liquids (or mixtures, waste water, waste materials) from one location to another.
Q:Operating procedures for measuring pumps
start-up1. Adjust the stroke indication to zero by adjusting the nut or handle with the rotary stroke.2 open the outlet valve.3. Open the inlet valve, pump, exhaust from the high point, exhaust from the relief valve, the breather valve.4, point motor, check the operation of the pump.5. Start the motor.6, without pressure on the premise, every 15 minutes to improve the stroke 20%, if there is no pressure, do not substantially improve the stroke.Note: (1) whether the sound or vibration of the pump is abnormal (2), whether the stroke adjustment is automatic or not
Q:The function of centrifugal pump
6. Stuffing box mainly consists of packing, water seal ring, stuffing box, packing gland and water seal pipe. The function of the stuffing box is mainly to close the gap between the pump shell and the pump shaft. The water in the pump is not allowed to flow outside and the outside air is not allowed to enter the pump. Always keep the vacuum in the pump! When the pump shaft and packing friction heat, it is necessary to rely on water seal to control water into the water ring, so that the filler cooling! Keep the pump running properly. Therefore, in the water pump running inspection process, the stuffing box inspection is to pay special attention to! In the operation of about 600 hours, it is necessary to replace the packing.
Q:Water pump outlet valve sequence
To reduce the impact of vibration, noise and vibration on the valve, the soft connection is best at the pump outlet.The check valve is sometimes checked, so it is placed in front of the outlet valve so that the water can be checked out. I think the order should be: pump outlet, soft connection, check valve, gate valve (butterfly valve)
Q:Types and differences of pumps
Classification and working principle of pump by structureClassification of pumpsInvolved pump standard product types are also very much, a centrifugal pump, metering pump, screw pump, reciprocating pump, hydraulic pump, submersible pump, oil pump, water pump, pressure test pump, vortex pump, cryogenic pump, vacuum pump, roots pump, molecular pump, gear pump, mud pump, corrosion-resistant pump deep well pump, water pump, mixed flow pump, axial flow pump, boiler feedwater pump, liquid pump, injection pump, chemical pump, pump plugging and no leakage pump, plastic pump, fire pump and so on, there are many. Its name is divided according to some conventional classification methods such as pump vane pump volume, pump etc., some are divided by purpose such as sewage pump, pump and other health, some names are more random as diffusion pump, liquid nitrogen pump. As long as the production of this product, with standard requirements, through a certain application and approval procedures may produce a new The standard, but sometimes the content also has a repeated cross, quite. The domestic and foreign standards, the domestic standard is more than the number of foreign standards. In general, such as centrifugal pumps are widely used, the production history of the pump more standard (total standard centrifugal pump up to more than 100). As new standard pump leakage pump this rapid development is relatively small. This paper introduces the structure and working principle of the pump according to the classification of the
Q:What is the pump, how to classify, mainly used in where?
2. other classification of pumpsThe pump can be divided into two parts according to the position of the pump shaft:1) vertical pump2) horizontal pumpDivided by the number of suction ports:1) single suction pump (single suction pump);2) double suction pump (double, suction, pump)According to the prime mover of the drive pump:1) electric pumps2) steam turbine pump3) diesel engine pump[other details]

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range