XLPE/PVC insulated PVC sheath underground power cable

Ref Price:
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
1000 m
Supply Capability:
20000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specifications

1.PVC insulation CU/AL conductor 
2.multi core armour cable 
3.medium voltage 0.6/1KV 
4.good quality low price 
5.OEM available

1.Standard: GB/T12706/IEC60502 or according to customer’s requirements

2.Voltage Rated:  0.6/1KV, 6KV, 8.7/15KV, 12/20KV, 26/35KV

3.Application: It's applies to electrical power transmission and distribution lines with AC rated voltage up to and including 0.6/1KV. For outdoor and indoor installation in damp and wet locations , laid directly in the ground. 

1,The general type cable are suitable for rated AC voltage 0.6/1KV and below electric lines without flam-retardant or fire-resistance requirements.

2,The flame-retardant type cables are not easy to burn or their flame propagation is limited only in a certain length. . These cables are suitable for high installation density places like power station, subway, tunnel, high-building, large industrial enterprise, oil field and main etc.

3,The fire-resistant cables can not only operate in normal condition, but also can operate in fire during a certain time. These cable are suitable for power station, subway, high human density places where having fire-proof and fire-fight requirements.

4. Operating Features

1, Max .Long-time operating temperature of PVC insulated cable is 70°C

Max .Long-time operating temperature of XLPE insulated cable is 90°C

2.Installing temperature of cable should not be less than 0°C

3, Max short-circuit temperature is not exceed 250°C, Not more than5 Sec.

4,Ambient temperature of installation is not lower than 0°C

5,With good chemical stabilities, such as resistance to acid, alkali, salt, oil and organic solvent and flam-retardant..

6,With light weight, good character, easy to installation and maintenance.

5.Norminal cross section size of conductor: 1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2, 500mm2  630mm,

6.Cores available: Single core, 2 cores, 3 cores, 4 cores, 5 cores, 3+1 cores, 3+2 cores, 4+1 cores.

7.This series of Copper Cables  include models as below:

Type

Description

Cu Core

Al Core


VV

VLV

Cu/Al core power cable with PVC insulation PVC sheath

VY

VLY

Cu/Al core power cable with PVC insulation PE sheath

VV22

VLV22

Cu/Al core, steel-belt armored power cable with PVC insulation PVC sheath

VV32

VLV32

Cu/Al core, thin-steel-wire armored power cable with PVC insulation PVC sheath

VV62

VLV62

Cu/Al core, non-magnetic-steel-belt armored power cable with PVC insulation PVC sheath

VV72

VLV72

Cu/Al core, non-magnetic-steel-wire armored power cable with PVC insulation PVC sheath

YJV

YJLV

Cu/Al core power cable with XLPE insulation PVC sheath

YJV22

YJLV22

Cu/Al core, steel-belt armored power cable with XLPE insulation PVC sheath

YJV32

YJLV32

Cu/Al core, thin-steel-wire armored power cable with XLPE insulation PVC sheath

YJV62

YJLV62

Cu/Al core, non-magnetic-steel-belt armored power cable with XLPE insulation PVC sheath

YJV72

YJLV72

Cu/Al core, non-magnetic-steel-wire armored power cable with XLPE insulation PVC sheath

8.Specification Size and Technical Data:

Core number

Nominal Section(mm²)

D.C.Resistance in 20 °c(Ω/km)

 

O.D.(mm)

Reference Weight(Kg/km)

CU

AL

Cu

Al

 

 

 

3 core

1.5

17

10.7

141

2.5

23

17

11.5

180

134

4

30

23

13.6

255

183

6

39

30

14.9

341

228

10

54

41

16.3

470

285

16

71

55

19.6

697

363

25

99

76

23.4

1049

568

35

120

92

25.8

1370

702

70

186

143

28.7

2350

1031

95

227

175

32.8

3144

1355

120

262

203

34.9

3882

1624

185

352

272

43.9

5945

2464

240

420

324

49.2

7647

3132

 

 

 

 

 

 

3+1 core

3×4+1×2.5

31

23

14.2

289

202

3×6+1×4

40

31

15.8

386

262

3×10+1×6

54

42

17.3

548

329

3×16+1×10

72

56

20.5

793

408

3×25+1×16

98

75

24.6

1196

608

3×35+1×16

122

94

26.9

1518

744

3×50+1×25

153

118

27.9

2032

931

3×95+1×50

231

178

35.1

3683

1583

      3×120+1×70

267

207

37.9

4617

1924

3×150+1×70

315

242

41.7

5563

2306

3×185+1×95

362

279

46.4

6929

2854

 

9.Construction:

No: of cable cross: 1 core(Single core),2cores(Double cores),3cores, 4cores(4 equal-section-area cores OR 3 equal-section-area+1 small section area neutral core),5cores(5 3 equal-section-area cores+2 small area neutral cores OR 4 equal-section-area +1 small area neutral cores).We provide armored type and non-armored type for the cables stated above.

About us:

Our company is specialized in conductor ,such as: AAC, AAAC, ACSR/AW, ACS, ABC CABLE, PVC insulated Wire and flexible Eire, PVC insulated Power cable, XLPE insulated power cable


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:The wall was sideways opened a trough how to do ah?
PVC pipe. Iron pipe, trunking, bridge, hose, and so on. The The PVC pipe, trunking generally the most common, used in the kind of request is not very strict, not much bit line. Capital is not high, low cost, iron pipe bridge is mainly used in fire strict buildings, shopping malls, high cost, security, line points and more use of bridge hose used in the line out of the floor to the desktop section. Nice point of the ceiling. Overhead floor, are suitable for placement is not comprehensive, personal experience
Q:What is the difference between VV22 and VV62?
Cable flow current is to be hot, look at the table with a look at the current is normal, the current is consistent with the cable configuration. Laying the environment is normal.
Q:Is the power cable considered a fixed asset?
Is fixed assets fixed assets - machinery and equipment - conductive equipment
Q:What is the difference between a pre-branch cable and a punched clip?
. soil buried pipe, including weak and fire, should be thick-walled galvanized steel pipe, that is, SC series of steel pipe, the best size is not less than SC. weak professional, decorative professional now basically use thin-walled galvanized steel pipe, that is JDG series steel pipe
Q:Power cable inspection, how many meters should be sampled?
meaning: ZR represents the flame retardant properties YJ said cross-linked polyethylene insulation V said PVC jacket ZR-YJV table red copper core XLPE insulated PVC sheathed power cable 4 * 70 + 1 * 35 said 4 core 70mm2 + 1 core 35mm2
Q:What is the radiation of the laser scanning scanner?
Shield For uniform conductive wire and insulated electric field, 6kV and above in the high-voltage power cables generally have a conductive shield and insulation shield, part of the low-voltage cable is not set shield
Q:What is the difference between a trough bridge and a tray tray?
The line is to be reserved, the installation will have a certain degree of tightness
Q:How high voltage armored power cable is grounded
Insulated isolation of the double shield control cable is the outermost armor layer should be grounded at both ends, the inner shield one end of the ground, is conducive to the rapid release of induced current.
Q:What are the lines that need to be set up for notebooks?
YJV cable is cross-linked polyethylene insulation, VV cable is PVC insulation, the former temperature level higher than the latter, such as the former conductor temperature can be 90 degrees, while the latter can only to 70 degrees!
Q:How to determine whether the square of the cable is standard
Depends on your number is not arranged in order, the general building room when the patch panel and the user board number is one to one correspondence

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range