XLPE Insulated PVC Sheathed Control Cable

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT or LC
Min Order Qty:
100 m
Supply Capability:
100000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Product Introduction:

XLPE insulated control cable is suitable for A.C 50Hz control loop rated voltage up to 0.6/1kV in power plants、transformer substations、factories  and petrochemical factories, using as the connecting wires between  automatic applications and meters. It transfers electricity and make the  whole electric system run safely and steadily.  

 

  Characteristics

1、It has good cold resistance、acid resistance、alkali resistance and could be used as organic solvent.

2、It has good performance in bending and has compact structure.

3、The insulation has good ventilation ability, so the overloading capacity for current

 

Specification:

Types

 Designation

Standards

KYJV

Copper conductor XLPE insulated PVC sheathed control cable

Q/321023KLA18

KYJVR

Copper conductor XLPE insulated PVC sheathed soft control cable

KYJVP

Copper conductor XLPE insulated PVC sheathed braid shielded control cable

KYJVRP

Copper conductor XLPE insulated PVC sheathed braid shielded soft control cable

KYJVP2

Copper conductor XLPE insulated PVC sheathed copper tape shielded control cable

KYJV22

Copper conductor XLPE insulated PVC sheathed steel tape armored control cable

Specifications

Type

Rated voltage

kV

Nominal core cross section

mm2

0.75

1.0

1.5

2.5

4

6

10

Number of core

KYJV

KYJVP

0.6/1

2~61

2~14

2~10

KYJVP2

4~61

4~14

4~10

KYJVR

4~61

KYJVRP

4~61

4~48

KYJV22

7~61

4~61

4~14

4~10

 

 

 

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Will the two 16 square copper wire with what specifications of the trunking
How to say that interference is certainly some, if you line less words on one or two in the bridge next to do a tube it! The pipe will be a little better. Upstairs that I do not think that although in practice the construction of this practice a lot, because you do not feel the interference, but the reality does interfere with, or science should not be strong and weak must be separated.
Q:Power cable inspection, how many meters should be sampled?
in the wide-linked pricing software GBQ40 to achieve, directly enter the corresponding quota, click on the quota below the" standard conversion ", the cable laying five core check , You can achieve the fixed sub-sub-multiplied by the coefficient of 13 For example: YJ - cross-linked polyethylene insulation (insulation) V - PVC jacket (outer jacket) did not mark the conductor material that is the default copper wire, if the aluminum wire should be YJLV4 * 70 + 1 * 35 core (Mm ^ 2) + Neutral core (indicated by "1") × Neutral core cross section (mm ^ 2) CT - Indicates the cable tray in the laying mode
Q:What is the role of patch panels generally, why should the switch connected?
If you are in a small city or town, go to some of the aluminum core series of cable (if you are in a small city or town), if you are in a big city, ask high, with copper core BV, BVVB, RV, VV series line Better, according to the level of regional economic development to purchase the cable, wire type.
Q:The difference between power cable and overhead cable
. the power cable occupies less. Generally buried in the soil or laying in the room, the channel, the tunnel, the line between the insulation distance is small, no tower, covers an area, basically does not occupy the ground space. The overhead cable is the opposite. . power cable reliability. Affected by climatic conditions and the surrounding environment, transmission performance is stable, high reliability. . the power cable has to ultra-high pressure, large capacity development of more favorable conditions, such as low temperature, superconducting power cables. . the power cable distribution capacitor larger. Overhead cable is the opposite . the power cable maintenance work less overhead cable is the opposite . the power cable electric shock is unlikely. The overhead cable is the opposite
Q:What is the difference between the control cable and the compensation cable?
. you want to achieve remote switch, right? In fact, from the host side of the original fixed switch button that cut the two lines, and then then you need to extend the extension cable you can, the super simple; . Internet cafes router, through the exchange (or hub) , Can achieve port expansion capabilities, you can access a lot of computers, but the Internet speed is limited by the router exit speed, that is the maximum speed will not exceed the router exit speed, and broadband providers will be on the server side of the uplink and downlink speed (That is, to provide customers with the speed) restrictions.
Q:How to determine whether the square of the cable is standard
laying the dark tube should be used when the steel pipe or flame retardant PVC pipe
Q:What is the meaning of "cable tray: 200 * 100 middle strip" in electrical engineering
About 35m distance, with the copper clad aluminum wire, so that basically do not affect the electric car charging voltage. The best use of plastic leather wrapped copper wire, if the copper wire, then the wire will increase slightly, but will not affect the electric car charging. Only the line is too long, the wire sagging pull the charger will be the output of the end of the wire, which may be the charger inside the solder joint pull off. To solve this problem is to extend the output wire, the charger should be fixed to the output line, so as not to affect the charger. I hope my answer will help you. -------------------------------------------------- -------------------------------------------------- -------------------- The above content is based on "stupid do not know" personal experience to write, only on behalf of personal views and opinions, no one shall arbitrarily modify, It is forbidden to plagiarize. Please refer to the source.
Q:Whether the interior decoration is the first brush latex paint or the first installation of the wire (the line, with the trunking)?
The 4.0 square wire refers to the air conditioning power cord single copper core cross-sectional area of 4 square millimeters.
Q:3 (WDZBN-YJV-4x240 + 1x120) cable how to interpret
3 halogen-free low-burn A-class flame-retardant cross-linked insulated PVC sheathed 4 main core per core 24 square millimeters, 1 ground 120 square millimeters cable.
Q:Can cable TV signal lines and network cables be placed in the same line when upgrading? What happens if you are in the same line? Thank you.
Wired do not need to set what ah, directly to the network cable can be inserted into the network port

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range