WQ Submersible Sewage Cutter Pump Sewage Pump

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
1000 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

 WQ Submersible Sewage Cutter Pump Sewage Pump

My company has more than 40 years history, is the China general machinery pump industry association member units.My company has organized product research and development team, experienced high, intermediate technical staff.Complete production and processing, inspection, testing (pump performance test platform), and other equipment, to ensure that product quality is stable and reliable.Over the department, provincial, municipal and industry product quality supervision and inspection (smoke), only one is qualified to go through.Timely quality perfect after-sales service in place, favored by the majority of new and old customers rely on and praise.My company has successfully passed the national industrial products production license, ISO9001 quality system review replacement work.Relevant product standards (enterprise), metrology, standardization management system, etc., have been acceptance by the superior department in charge of the inspection.Related to product development, production management, sales and after-sales service, are performed according to the system management standard.

 

Application

This series pump is widely used for sewage treatment of city construction discharge for architecture projects, hotel, mine, pond, dyeing and printing, paper making and textile industries.

It is the ideal tool for transportation of sludge, slurry, living sewage, feces and stale wastes, solid grains fiber, paper chips, sandy soil etc.



Model Description


100WQ 50-30-5
100: Drain aperture (mm)
WQ: Submersible sewage pump

50: Capacity (m3/hr)
30: Head (m)
5: Power (kW)

Operations Conditions


1. The medium temperature should not be over 60oC, the density 1200Kg/m3, and the pH value within 5-9.
2. During running, the pump must not be lower than the permitted lowest liquid level.
3. Rated voltage 380 V, rated frequency 50 Hz. The motor can run successfully, only under the condition the deviations of both rated voltage and frequency are not over ± 5%.
4. The maximum diameter of the solid grain going through the pump has not to be larger than 50% of that of the pump outlet.


Picture

 WQ Submersible Sewage Cutter Pump Sewage Pump

Why choose us

 High Quality
1.Exported to 58 Countries
2. More than 90% customers make payment before meeting us!
3. Reorder rate up to 80%
4. Never sell any renewed pumps
5. Focus on middle and high-end market,we never seize market by using inferior material

FAQ

1. How to get our quotation in time, pls answer following questions:
    1)What liquid do you transfer?oil ,food or corrosive chemical liquid,with solid particle or not and so on 
    2) What's the flow or capcity (m3/h, L/m)? 
    3) What's the discharge head (m, feet, Mpa, bar )
     If you do not have any request, we will do as our normal standard.
  4) Contact us by under  business card information
2.OEM: Ok 
3. MOQ: 1set
4. Package: Standard export wooden case(also according to your requirements)
5. Shipping ways: By sea, By air, By express
6. Lead time: 3-15days
7. Warranty Period: One year, except spare parts 

 


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Intelligent pump controller, water is full water transfer automatically shows the next pool of water shortage, what is the matter?
The intelligent controller of water pump is full of water and automatically shows the shortage of water in the lower pool. The reason is that the sensor is out of order or the line is out of contact. First of all, make sure that the upper limit of your controller is normally open or normally closed. When the upper limit is reached, does this point change? If the original upper limit position is normally open, check the switch and pump insulation.A pump is used to increase the pressure of a liquid or gas, the flow conveying machinery, and "jump" or "flow" is a homonym, is a transliteration of the English pump, is a device used to move liquids, gases or special fluid medium, which is reactive to the fluid machinery. The heart of man and animal can be said to be a natural pump, which carries blood to all parts of the body.
Q:Does the IP55 indicate the lift on the water pump nameplate?
IP55 represents the waterproof and dustproof rating of the motor
Q:My fish tank pump is deep enough, it doesn't bubble up. Without oxygen supply, but it can filter. Does it damage the pump itself?
Three in one pump with a hose connected to the oxygen pump as the pipe above the water so that the air will enter the pump, you can spit bubblesYou put it too deep and put the hose into the water too. Without air, you can't spit bubblesIf the pipe is not long enough, you can find a hose for the oxygen pump instead of a long tube, with the hose out of the water and fixed
Q:Water pumps are always pumping water, what's the matter?
Cause analysis of water pump without waterThere is air in the inlet pipe and pump body(1) before the water pump is started, the water is not filled enough. Sometimes it seems that the water has been discharged from the vent hole, but the pump shaft is not rotated. The air is completely discharged, resulting in a small amount of air remaining in the inlet pipe or pump body.(2) in contact with the water pump inlet of the horizontal application of reverse flow direction, fell more than 0.5% slope, connect one end of the highest import pumps, do not completely level. If the upward tilt, the intake pipe will retain air, reducing the water pipes and pumps in the vacuum, water absorption.(3) pump packing has been used for long-term wear or packing pressed too loose, discharge gap caused by the large amounts of water from filling with the shaft sleeve, the external air gap into the pump from the inside, affected the water.(4) because of the long latent water and the corrosion of the pipe wall, the water inlet of the water inlet is constantly dropping. When the holes appear above the water, the air enters the water inlet pipe from the hole.(5) there is a crack at the bend of the inlet pipe, and there is a small gap between the inlet pipe and the water pump, which may cause the air to enter the inlet pipe.
Q:Multi storey residential buildings also need to set up pressurized water pump room, direct water supply can not be?
Multi-storey residential building in general can use tap water pipe network pressure water directly, but all regions due to different network differences, in some areas, because of the lower pressure of the municipal pipe network, such as lack of high-rise building 5-6 pressure, can direct water supply cannot meet the demand of domestic water use, then you need the two pressurized water supply. The general water supply equipment needs the construction of pumping stations, and the pump house can be built on the first floor or the ground floor. There are also no water supply equipment, such as pipe pump, frequency conversion water supply equipment, the water supply equipment from outside to see, is a group of stainless steel pipeline, no pumping room. Outdoor box type water supply equipment is also a choice, water supply equipment comes with equipment, can be placed outdoors. Zibo Boshan new Duke water supply equipment
Q:How can the pump be stationary?
1, the pump bearing lubrication interruption, bearing burn.2, locking the rotor is jam.3, foreign body corrosion serious impeller lock.
Q:Ask the principle of fire truck and pump adapter
Fire trucks to bring their own water, when the water is insufficient, the municipal pipe network, water fast docking adapter or outdoor fire hydrant. These look at the specific conditions of the scene, usually take more outdoor fire hydrant, because the outdoor fire hydrant connecting the municipal pipe network, fire pool and other water sources, you can guarantee the reliability of water supply.
Q:The flow of the pump will be reduced, the speed will change, the power of the motor will change?
To be sure, the flow rate decreases and the speed decreases! The change of power depends on the change of the lift! If the flow rate decreases and the head rises, the power is likely to remain unchanged!
Q:Is the motor with a pump a squirrel cage induction motor?
Should be a squirrel cage motor for winding asynchronous motor for high torque applications. For example, its structure and the hoist crane cage motor with different rotor loop it can slip ring external resistor. The motor rotor circuit principle know that certain external resistance can reduce the starting current, but also can improve the rotor circuit power factor and torque. The pump load does not need large torque. So it should be the squirrel cage induction motor.
Q:How to change the frequency of a water pump with a pump?
Only trip is not to the frequency converter settings or phase sequence change, if not moved the settings and wiring, most of the reason is the original reversal, you also know that inverter turnover also has water.Check analog positive and negative polarity, inverter settings, and if there is no problem, change the phase sequence.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range