• WQ series Submersible Centrifugal Sewage Pump with high performacne System 1
  • WQ series Submersible Centrifugal Sewage Pump with high performacne System 2
  • WQ series Submersible Centrifugal Sewage Pump with high performacne System 3
WQ series Submersible Centrifugal Sewage Pump with high performacne

WQ series Submersible Centrifugal Sewage Pump with high performacne

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
1000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Product Description:

Product outline
WQ series submersible sewage pump absorbs the advantages with the same products made abroad and at home, holds a comprehensive optimized design on its hydraulic model, mechanical structure,sealing, cooling, protection, control etc. points, features a good performance in discharging solids and in the prevention of fiber wrapping, high efficiency and energy-saving, strong reliability and, equipped with a specially developed electric control cabinet, not only the auto-control can be realized but also the motor can be made sure to work safely and reliably.Available with various types of installation to simplify the pump station and save the investment.
WQ series submersible sewage pump is mainly used for the municipal works, buildings, industrial sewage and sewage treatment to discharge the sewage, waste water and rainwater containing solids and long fibers.
Characteristic and advantage
1. Most of the impellers with the pump of an aperture below 400 come as a bi-runner impeller and few of them is a multi-blade centrifugal impeller. While most of the impellers with the pump of an aperture 400 and above come as a mixed flow impeller and few of them is a bi-runner impeller. The spacious pump casing runner lets the solids easily passing and the fibers uneasily wrapping so that it is most suitable for discharging sewage and dirt.
2. Two independent single end-face mechanical seals are in-series mounted, with the installation mode as the internal installation mode, and, compared with the external installation mode, the medium is more uneasy to leak and also its sealing friction pair are easier lubricated by the oil in the oil chamber. A special spiral slot or a small seam is used to resist the solid
grains to be deposited on the mechanical seal by the pump to make sure of its stable work. The unique mechanical seal layout mode and bearing combination makes the suspension arm of the shaft short, a heavy rigidity and a small jump, more benefit for reducing the leak from the mechanical seal and extending the life of it.
3. The motor of a protective grade IPX8 works in submerged mode and holds the best cooling effect. The grade F insulation makes the winding bearable to a higher temperature and, compared with common motors, more durable.
4. The perfect combination of the special electric control cabinet, the liquid level floating-ball switch and the protective components carries out the automatic monitor and alarm for
water leak and winding overheat, the protections at shortcircuit, overload, lack-of-phase and voltage-lost cut-off, the accurately auto-controls of start, stop, alternation and minimum
submerged depth of the pump, without need of special persons for looking-after, option at will is available between the selfcoupled reducing start and electronic soft start. All of these
makes sure of safe and reliable use of the pump without any worry.
5. Both motor and hydraulic parts are directly linked together, without need of turning the shaft for centering, easily disassembled and assembled to save the time, benefit for the
site maintenance, reducing the stopped time, saving the cost of repair; simple and compact structure leaves a small volume, only simple lifting equipment is needed, as a special lifting
handler is set on the pump; less land area and the pump can be placed directly in the sewage pond, without need of a special pump house, and the therefore the construction investment
can be saved by over 40.
6. Available with five installation modes for you to choose: auto-coupled, movable hard-pipe, movable soft-pipe, fixed wet type and fixed dry type installation modes.The auto-coupled installation means the connection between the pump and the water-out pipeline is made with the water outlet pipe seat of the auto-coupling, without use of the common fasteners, and, when to separate the pump from the water outlet pipe seat, just place it down along with the guide rod and then lift it, simply enough to get free from worry and trouble and save time.
The submersible sewage pump in the fixed dry type installation not only can replace the old vertical sewage pump but also does not fear of flood submersion, so there is no need of a separate flood-proof facility, benefit for lowering the cost of construction.


Q:What flowmeter is installed after the pneumatic diaphragm pump?
Compressed air source, the general pneumatic diaphragm pump starting gas source for 0.1~0.2mpa,The maximum working pressure is 0.7~0.8mpa, so in this pressure range, you can use the air filter relief pressure valve gas pipe, adjusting for air pressure, when the pressure is bigger, diaphragm movement faster, so the greater the flow, and vice versa
Q:Rotary vacuum pump does not meet the requirements of vacuum, what are the reasons?
(1) the disk, stator or bushing is worn and shall be inspected, trimmed or replaced with a rotary vane vacuum pump.(2) the pump temperature is too high, which not only reduces the viscosity of the oil, increases the saturated vapor pressure, but also may cause cracking of the pump oil. Ventilation, cooling and environmental temperature should be improved. If the exhaust gas temperature is too high, should be cooled before entering the pump, the environment temperature is high, should try to use a better high speed vacuum pump oil or 3# diffusion pump oil. (10) because of the deformation, wear or movement of the parts, the maximum opening height of the check head can be reduced or even unable to be opened, the intake of oil is too little, and the vacuum degree of the rotary vane vacuum pump is reduced, and should be adjusted as shown in the assembly section. Open high, more oil, but open too high, check valve in some places on the stop, it will not automatically drop, lost to prevent oil returns. The commonly used rotary vane vacuum pumps mainly include double stage rotary vane vacuum pump and single-stage rotary vane vacuum pump
Q:How many pumps does the 80cm tank use?
Filter pump to select the water per hour can be filtered more than 3 times, I personally feel that this is almost enough. Of course, the more times the better, but also consider that if the pump is too large, the water inside the tank will be too large.128X3=384LThat is, the flow must be more than 384L/H of the water pump.You can buy a bigger pump, because the pump for a long time there will be some attenuation and domestic things in general to sign data, so it should be based on your actual situation to buy. Taobao on this category is about 20~40 yuan.
Q:Operating procedures for measuring pumps
First, preparation and inspection before starting1. Check to make sure that the drain line is equipped with a safety valve with the correct set pressure.2. Check the screws for the liquid end parts.
Q:Does vacuum pump oil belong to dangerous goods?
Absolutely not. We often send oil by express or by freight. There are no problems at all. Don't be afraid, don't burn, explode
Q:What are the parts of a pump? How do you classify it?I just want to know
According to the working principle can be divided into: centrifugal type and volume type centrifugal pump. By the centrifugal force of the impeller will accelerate the refrigerant, through to stay, so as to achieve the purpose of boosting; volume by changing the refrigerant in the flow volume to boost purpose.According to the media and installation conditions, water pump: centrifugal pump used: the impeller pump shaft, a curved blade on the impeller impeller outlet. The central entrance water vertically along the tangential direction of axial flow pump: high speed, large flow, low lift, mixed flow pump and centrifugal pump structure similar to that of the blade outlet angle is different, wide flow channel, close to the performance of axial flow pump displacement pump: safety valve must be opened before the start (metering pump, screw pump)
Q:Harm of air pump and pump
Centrifugal pump situationEmpty pump is divided into two kinds, if there is no liquid, then it will cause the mechanical seal of the pump to overheat, wear and even die
Q:The suction pump has a nominal suction range of 30 metersHow deep can a well be sucked?Well, sixteen meters,
Vacuum pump plus form must not reach a standard atmospheric pressure vacuum, so the general can absorb 8 meters is very good, and the self suction pump itself and loss, the horizontal self-priming pump can suck on basic 4~6 meters is very good, self-priming pump. Suction lift of 30 meters is purely in the Mongolian people, does not comply with the laws of nature, obvious anti science.
Q:There are 6 pumps, two indoor fire hydrant pumps, two spray pumps, two outdoor pumps, three units, one master and one spare control cabinet. From the control room to the control cabinet, is there only 3 lines or 9 lines?... How do I get it? Where does the hydrant line come from?
Spray pump in addition to remote direct Kai, there are modules to start function, that is, on the cabinet to add control module, bus linkage pump, in addition to the pressure switch, directly pumping function, a total of three functions.
Q:What are the conditions required for hydraulic pumps to complete oil absorption and compression?
There must be one or more sealing volumes, and the volume of work is variable;

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products