Wire harness with connector

 

Detailed Product Description

 1.Power cable assembly

2.Replacement of famous connector sell at low price,

3.OEM Sample time:1-3day,

4.UL,Rohs compliant.
5:Molex cable assembly

6:Equivalent/substitute/equal of jst xh connectors

 

 Specifications:

1: Wire Harness Assembly , cable assemblies

2: BYD, Phillips Vendor,
3: ROHS, UL, ISO9001, ISO14001 complicant
4: 100% test before ship

 

Wire Harness Assembly , cable assemblies

Range of wire harness

 

1.Wires for Home Appliance

11.XLPE Wire

2.Locomotive Harness, Generator , Lamp Harness

12.COAXIAL Wires

3.Office Appliance Harness And Telecom Harness

13.High temperature cables

4.Electronic and Computer Harness

14.CMP network wire

5.Aluminum Foil Thermal Stats

15.MPPE Wire

6.Silicone wire

16.NS serial special wires

7.Teflon Wire

17.Thermocouple compensating lead wires

8.PVC/XLPVC Wire

18.Silicone Sleeves

9.HDMI Cable

19.Antenna Series

10.TPE\TPU Wires

20:LED

 

 

Why we choose Okorder.com?

Okorder.com is a professional and reliable online E-market place

Providing a variety of products with reasonable prices

High quality goods provided by factory suppliers

Shipping to over 200 countries.

One-stop sourcing

Dubai Logistic Complex

 

Okorder Quality Control?

We hold a very strict quality control system to check every connector of our products for your safety.

 

Okorder services for you

1.7*24 hours Hotline & Email Service

2. Your inquiry related to our products or prices will be replied in 24hrs.

3. Well-trained and experienced staffs to answer all your enquires in fluent English

4. OEM&ODM, any your customized demand we can help you to design and put into product.

5. Distributor ship are offered for your unique design and some our current models

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to connect the power cable pre-branch connector
In the pre-measured size cut out the jacket and insulation, according to the different cross-sectional size of the cable cut the size of the jacket and insulation different; with C-shaped tube corresponding to the corresponding color sequence crushing the trunk and branch lines, crimping attention to crimping The strength of the clamp, can not be too loose or too tight, too loose will cause the cable crimping off, resulting in open circuit, crimping too tight will break the conductor or cause the conductor stranded in the contact with a good conductor with polytetrafluoroethylene With the winding baking transparent, and then wrapped waterproof tape (tiger belt) can be used after the wooden hammer shrink the cable core to facilitate injection molding in the injection process should choose the appropriate mold and injection molding machine injection mold injection, the mold is too large cost Waste, the mold is too small caused by defective, bad seal at both ends of the running coke, affecting the injection effect
Q:What is the difference between VV22 and VV62?
Copper core conductor PVC insulated PVC sheathed double steel tape wrapped armored type power cable copper conductor PVC insulated PVC sheathed non-magnetic metal armored power cable difference is the type of armor material
Q:What is the use of wire and cable per square meter of residential building?
Generally wear SC65 tube. If the distance is too long, elbow and more, then the choice will be larger.
Q:Cable WDZ-YJFE2 (4X185 + 1X95) what does it mean
Bracket spacing of the general level of not more than 2m, vertical not more than 1.5m according to the number of cable the number of levels can be used 1.5m a vertical 1m a relatively insurance
Q:What is the radiation of the laser scanning scanner?
Semi-conductive shield The semi-conductive shield is usually disposed on the outer surface of the conductive core and the outer surface of the insulating layer, referred to as the inner semiconducting shield and the outer semiconducting shield, respectively The semiconducting shield is made of a semi-conductive material with a low resistivity and a low thickness Internal semiconducting shielding layer is to uniform the outer surface of the electric field, to avoid the conductor surface is not smooth and the core stranded by the air gap caused by the conductor and insulation occurred partial discharge The outer semiconducting shield is in good contact with the outer surface of the insulating layer and is electrically connected with the metal sheath to avoid partial discharge of the metal sheath due to defects such as cable insulation surface cracks For non-metallic jacket in the low-voltage power cable, in addition to the semi-conductive shielding layer, but also to increase the metal shield Metal shield is usually made of copper or copper wire wrapped around the main play the role of shielding the electric field
Q:Why does the sparrow stand on the wire without electric shock?
AC power is a two-phase exchange of the power system, itself is positive and negative exchange, the electromagnetic effect can almost count the daily life of the free radiation are more than this number, and can rest assured that the general life supplies, the larger electromagnetic radiation from the DC Of electrical supplies, which only need to pay more attention
Q:What are the varieties of wire and cable (detailed point)
Chien fiber optic transceivers fiber optic cable flange fiber box fiber jumpers welding machine. Our company: Qin Sheng network
Q:Where the computer can be a bare chassis. Which hardware inside the framework
It is best not to use this, because you have no way to test the signal line. There are special 10 line 8 line terminal telephone switch patch panel
Q:What is the power cable accessories used to do?
Do not know what you want to ask? What about your situation? Normal or pregnant? Normal this radiation does not affect what, if it is pregnant, this is far away from the best. Pregnancy is most needed to stay away from the microwave!
Q:3 (WDZBN-YJV-4x240 + 1x120) cable how to interpret
3 (WDZBN-YJV-4x240 + 1x120) cable is a low smoke halogen-free flame retardant (B grade) XLPE insulated - PE sheathed copper core power cable. The model of the cable is usually composed of eight parts: First, the use of code - not marked as the power cable, K for the control cable, P for the signal cable; so the power cable. Second, the insulation code -Z oil-impregnated paper, X rubber, V polyvinyl chloride, YJ cross-linked polyethylene; so for the cross-linked polyethylene insulation. Third, the conductor material code - not marked as copper, L is aluminum; therefore copper. Four, inner layer code-Q lead package, L aluminum bag, H rubber sleeve, V PVC jacket; so for the PVC jacket. . derived code-D no drip, P dry insulation. Sixth, the outer layer code. . special product code-TH wet tropical, TA dry tropical, ZR- (flame retardant), NH- (fire), WDZ- (low smoke zero halogen, enterprise standards); so low smoke halogen-free flame retardant The . rated voltage - unit KV; general cable are marked, the problem is estimated to write missing 0.6 / . the use of: rated phase voltage of 0.6KV, line voltage of 1KV. In the cable, 4 * 240 + 1 * 120 that there are 4 core 240 square copper wire, a 1-core 120 square copper wire.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range