Ref Price:
Loading Port:
Payment Terms:
Min Order Qty:
Supply Capability:
1000MT m.t./month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specification of white fused alumina



Apparent Porosity

Chemical Composition












Packaging & Shipping

In 1MT jumbo bag or as the buyer request.

We ship the cargo in 20' GP containers,each container loads 25MT/20bags.

Application of white fused alumina

1.Light-weight insulating refractories

2.Shaped and unshaped refractories

3.Pre-cast shapes and castables

4.High Alumina Refractory mixes and gunning mixes

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Does anyone knows which company produces the better refractory materials?
A:Building Materials Company of Guangzhou: Near the Baiyun District, Baiyun District, Guangzhou Road, North Road. B:Guangzhou Research & Development Co., ltd.: Liwan District Fengyuan road No.90 in Guangzhou City C: Huitailong decoration materials Co., Ltd.:the 30th floor of No. 111 Pacific Center, Taikang Road, Yuexiu District Guangzhou City D:Guangdong metal materials company: Near Qishan Road, Tianhe District , Guangzhou city.
Q:Which manufacturers have the best fire-proof materials with light weight?
It now appears that asbestos is the best among the most common fireproof materials. But asbestos also has great harm, especially to lung. Shanghai Xinlong Fireproofing Material Co., Ltd. and Hubei Boyue Lightweight Material Co., Ltd. were established in 2009. The company is located in Wuhan Biological New Town and covers an area of ​​30 acres. The company is a specialized enterprise which is mainly engaged in the research and development, production, sale and construction of lightweight partition board, lightweight fireproof wall panel and lightweight wall panel. The two companies are both good.
Q:What's the definition of fire endurance of the fire-resistant coating for steel structure?
1. Fire endurance. Conduct fire resistance test of any building component according to the standard time-temperature curve, and the time when it is subjected to the fire to the time when it loses support capability or fire insulation function or its integrality is destroyed is referred to fire endurance. 2. Steel has relatively low fire endurance which is usually 0.25h only, namely 15 minutes; 3. Of steel structure buildings, steel can be used as beams, pillars, etc. but its fire endurance is not enough (usually these components have higher requirement on fire endurance, and take pillar as an example, it is usually demanded that the fire endurance should be 2-3h), and under this condition, it needs to brush fire retardant coating so as to raise the fire endurance. As to the specific quantity or types of the fire retardant coating, it is decided upon the actual conditions. In short, the building material needs to meet the required fire endurance of the buildings.
Q:The following statement is correct: artificial corundum has a high melting point and can be used as a high grade refractory material. The main component is silica dioxide
Artificial corundum has high melting point and can be used as high-grade refractory material. The main component is silica, and the main component is aluminaThe chemist uses agate mortar friction solid reactant without solvent synthesis, the main component of agate is the main silicate is silicon dioxideThe early construction of the Three Gorges dam uses a lot of cement, which is made of silicate materialIn the summer, tourists wear by adding cuprous oxide silica made of glass color glasses to protect eyes [] color glasses is added to the material made of silver, it is now possible to have more advanced material, but the middle school stage is said with silver bromideIt sees light, decomposes easily, and combines easily, so use it.Solar cells can be made of silicon material, and its application is favorable to environmental protection and energy saving
Q:Who knows about the differences between 3M fireproofing materials and ShiLiDe materials?
Advertising materials can be divided into fireproofing and non-fireproofing ones which can not tell the differences with naked eyes. You can ask 3M to provide test reports or go to a the third party test organization SGS to do flame retardant test, maybe I can help you. Mineral wool board is harmful to human body, will lead to chronic poisoning, the quality of it is bad! You must pay attention to it! It can not be used in chemical and pharmaceutical plants.
Q:who knows the technology of fireproofing material?
First: Firstly, you should produce the recipe and prepare the raw materials, for example, if you prepare to produce 1 ton, you should compute the recipe sheet of 1 ton producing; check whether the raw materials are complete; second: make the color and filler thick liquid; add water in order and proper auxiliary in a low speed, then put color and filler (generally we should firstly add something with large oil absorption), wash the meachine after putting the powder. Then seperate them for about 20 miutes in a high speed, until the fineness is qualified; of course, if you need sander, i think you only need sino-soviet differential powder material and non-obvious particles. Third: Paint mixing period: after making the color and filler thick liquid, reduce the roll speed into about 600 roll per minute, add emulsion and proper auxiliary, finally adjust PH and viscosity. Liquid solvent paint, pigment paste: Resin,solvent and pigment ---〉pre mixing---〉stick---〉grinding--〉stick--〉packaging, highlight varnish: Resin, solvent ----〉mixing ----〉stick ----〉packaging, sub-gloss varnish: Resin, solvent----〉mixing----〉matting agent,stick----〉packaging, colored paint: The primary colorant----〉Color matching by auxiliary color paste----〉stick----〉packaging, aluminum paint: Aluminite powder soaking----〉resin----〉colour modulation, lustre adjusting----〉stick----〉packaging, powder coat: Resin,filler,pigment,auxiliary---〉mixing---〉extrusion---〉cooling---〉smashing---〉sieving---〉 packaging.
Q:Refractory material, refractory brick
1, according to the degree of refractoriness:Ordinary refractory material: 1580 ~ 1770 DEG CAdvanced refractory material: 1770 ~ 2000 DEG CSuperfine refractory material: >2000 DEG C2, depending on the shape and size of the product:Standard type: 230mm * 113mm * 65mm;No more than 4 measurements, (size ratio) Max:Min<4:1;Profile: no more than 2 concave, (size ratio) Max:Min<6:1;Or an acute angle of 50~70 degrees;Specific type: (size ratio) Max:Min<8:1;Or not more than 4 or a sharp angle; 30 ~ 50 degrees;Special products: crucibles, vessels, tubes, etc.3, according to manufacturing methods, refractory materials can be divided into:Fired products, unfired products, unshaped refractories4. classification according to the chemical properties of materials:Acid refractory material, neutral refractory material, basic refractory material
Q:how to classify the fireproofing material levels A1 A2 B1?
their classification is shown specifically in Fireproof  Specification of Building Interior Decoration Design GB 50222-95 appendix A, flammability,inflammability materials, flame retardency, noninflammability: combustion performance of A, B3, B2, B1 materials are divided into
Q:what is the requirements of roofing insulation materials fire rating?
The fireproofing requirements of architectural design are regulated by architectural design fire safety rules, roofing insulation material only has the requirements of materials combustion performance, namely non-combustible material. No fire rating requirements.
Q:What's the fire endurance of A grade fireproof glass curtain wall?
An hour and a half, an hour, and half an hour. As a key step in the home fire prevention, fire door is particularly important. According to the fire endurance and heat insulation performance, it can be classified as follows: A class fire door with fire endurance of no less than 1.5h; B class fire door with fire endurance of no less than 1h; C class fire door with fire endurance of no less than 0.5h. We can choose according to different needs, while A class fire door and B class fire door are now commonly used. Fire door has great varieties, and the material it uses is also of wide range. It includes stainless steel fire doors, glass fire doors, steel fire doors, etc. The most important feature of fire door is its fire resistance period. The main difference between A class fire door and B class fire door lies in their fire endurance, of which the former is no less than 1.5h, while the latter is no less than 1h. Difference between A class fire door and B class fire door also lies in their fireproofing material. That is the thickness of the built-in fire prevention board, of which A class fire door is 52mm, while B class fire door is 46mm. Therefore A class fire door obtains longer fire resistance period than that of B class fire door and gains better fireproof performance. A class fire door and B class fire door also differ in the places they are used. A class fire door is generally used in important fire fighting access of machine rooms, warehouses and oil depots, etc. and flammable and explosive public places, while B class fire door is generally used in the ordinary fire fighting access of some ordinary buildings. But B class fire door is more widely used than A class fire door.

1. Manufacturer Overview

Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range