Water Pump Serie Submersible Sewage Pump From China

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
100 set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1.Specifications

1)High performance
2)Mechanical seal
3)Cast iron impeller or bronze impeller
4)Lower vibration water pump
5)Large flow

2.Packaging & Delivery

Packaging Detail:

export wooden cases

Delivery Detail:

within 30 days once receipt of 30% T/T prepayment

BPO Irrigation Centrifugal Split Water Pump

3.FEATURES

BPO series single-stage double-suction open type centrifugal pump self-researched by the Company after absorbed advanced technology of similar products and combined application requirement of various customers. The series pump adopts excellent hydraulic model, wider type spectrum and better structure. Pump casing is produced by special machine tool, which ensures concentricity among shaft bearing, shaft and pump case, and provides better reliability and maintainability. Apply to municipal water supply and drainage, water circulation of air conditioner, agricultural hydraulic engineering, such as irrigation, drain flooded fields etc., industrial water supply system, firefighting system, water supply and drainage of
heating system, transportation of clean water

4. OPERATING CONDITION

a)Rotate speed: 2950r/min, 1480 r/min, 980 r/min, 730 r/min
b)Flow range: 64.4~9810m3/h
c)Delivery lift: =200m
d)Medium temperature: =80 ,
e)product adopting special materials: -20 ~120
f)Ambient temperature: Lower than 40
g)Operating pressure up to achieves 2.5MPa

5. MATERIAL 

a)Pump casing: Cast iron or magnesium iron
b)Pump cover: Cast iron or magnesium iron
c)Impeller: Cast iron, magnesium iron or tin bronze
d)Sealing ring: Cast iron or tin bronze
e)Pump shaft: 45# steel plated with chrome
f)Dynamic and static mechanical sea: Hard carbide, graphite
g)Configuring other material according to requirement is allowable

Rated flow

10(m3/h)

Rated head

26m

Rated power

1.5Kw

Voltage

220V

Rated Current

7.2A

Rated speed

2860r/min

Discharge diameter

50mm

6.Conditions of use

Pumps used in the following conditions should be continuously to work properly: 
1. For water pumps suitable medium, medium temperature shall not exceed + 40°C
2. The medium PH value between 6.5 ~ 8.5 
3. The volume of medium containing solid impurity is less than 0.1%, the size is not more than 0.2 mm 
4. The power frequency 50 hz, voltage for single-phase 220 v, 380 v, three-phase voltage fluctuation range for rating of 0.9 to 1.1 times 
5. Diving depth of no more than 5 m, is not suitable for irrigation and drainage of sewage and chemicals.

Water Pump  Serie Submersible Sewage Pump From ChinaWater Pump  Serie Submersible Sewage Pump From China


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Fire pump room is required to set up water pump control room?
What is the concept of fire pump control room? If there is a control room host automatic alarm automatic fire alarm system of words (through the pump distribution box can also control) can control the fire pump, if there is no distribution box automatic alarm system you can through the pump room control
Q:Installation position of check valve for water pump
Check valves must be installed at the pump's exit and position before the outlet control valve for servicing the check valve.Jiang Yuanyuan 1985's statement has a problem:1. On the flow of water, because the fluid is continuous and incompressible, the water in any part of the pipe will not flow as long as it is cut off in any position in the pipe.2, self suction exhaust is formed within the pump in outlet pipe, check valve installed in the inlet, because the pressure is low, is not conducive to automatically open the check valve, and its resistance, easy to form a vacuum pump and cavitation.
Q:Pump pumping small is what happened?
Multi pass is self-priming pump, right? Check that the water inlet pipe is connected. If there is a little leakage, the lift will not be high. If the submersible pump, impeller pump or screw pump, they do not have irrigation. If it starts small and then flows, it may be that the water in the well is not rising so fast, that is to say, the water is poor. This happens, too. If it starts small, which may be the well did not hit the good position. Suggest a little more. Is it used in your house? Still have other uses?. For home use. A bucket of water is enough.
Q:Does the water pump and the circulating pump belong to the centrifugal pump?
As long as the flow and head to meet what pump can be, the general centrifugal pump applications are more.
Q:Water pumps are always pumping water, what's the matter?
First check whether the water pump suction gas 2 check the negative pressure of the pump suction is too low 3 check whether the water pump 4 no problem of opening the pump head to check whether the water pump impeller damage
Q:How to install circulating water pump for cooling tower?
This should be installed at the inlet of the cooling tower. The water at the outlet of the cooling tower is returned to the pool
Q:What is the function of a submersible pump?
Submersible pump motor and pump is directly connected with the water pump body into the water to work, it is suitable for the extraction of groundwater from wells, can also be used in rivers, reservoirs, canals and other water projects: mainly used for irrigation and plateau in the drinking water, but also for the city, factories, railways, mining and construction site the use of water supply and drainage.Characteristics of submersible pumps for well1 、 motor, water pump, submerged operation, safe and reliable.2, the well pipe and pump water pipe without special requirements (i.e.: steel tube wells, tube wells, Doi ash can be used).3, installation, use and maintenance of convenient, simple, small footprint, do not need to build pumping stations.The structure is simple, and the raw materials are saved.4, submersible pump conditions are appropriate, properly managed, and has a direct relationship with the service life.
Q:What kind of water pump does the 5.5KW motor have?
Model has: QS-250-40-21, lift 21m, flow 40 square, motor power is 4KW, water pump diameter is 232cmQJ-200-40-26, lift 26m, flow 40 square, motor power is 5.5KW, water pump diameter is 189cmYou can choose the right pump according to your well path.
Q:How much is the flow rate of fire hydrant and spray shared water pump?
Fire fire water is superimposed, at the minimum, the lowest 5L/S automatic spraying fire hydrant, light danger level 13.9L/S, the least is 18.9L/S, but the data is useless, the data are not spraying fire hydrant, concrete analysis of high-rise buildings like the dangerous level according to the calculation, the general design, the concrete building needs the high-rise building minimum 20L/S, automatic spraying dangerous level according to the general 30L/S, 50L/S need to flow.Fire hydrant: fire hydrant (English Name: fire hydrant), a stationary fire fighting tool, with 4 iron chains. Fire hydrants are provided throughout the city to provide fire water for firefighters during the rescue. The main function is to control fuel, insulate combustion and eliminate fire source. The fire fighting system includes outdoor fire hydrant system, indoor fire hydrant system, fire extinguisher system, and some automatic sprinkler system, water gun system, gas fire extinguishing system, fire detection system, water mist system and so on. Hydrants are mainly fire engines from the municipal water supply network or outdoor fire water supply network to implement fire fighting, but also can directly connect hoses, water cannons, fire extinguishing. Therefore, the outdoor fire hydrant system is also one of the important fire fighting facilities.
Q:What's a small soft pipe for a submersible pump in a fish bowl? How do you use it?
Filter pump for oxygen spray. If the filter pump water flow, you can throw oxygen flowers, you can not use. With that pipe, it's loud and kind of

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range