Water Pump Made In China Good Quality On Sale

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
100 set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1.Specifications

1)High performance
2)Mechanical seal
3)Cast iron impeller or bronze impeller
4)Lower vibration water pump
5)Large flow

2.Packaging & Delivery

Packaging Detail:

export wooden cases

Delivery Detail:

within 30 days once receipt of 30% T/T prepayment

BPO Irrigation Centrifugal Split Water Pump

3.FEATURES

BPO series single-stage double-suction open type centrifugal pump self-researched by the Company after absorbed advanced technology of similar products and combined application requirement of various customers. The series pump adopts excellent hydraulic model, wider type spectrum and better structure. Pump casing is produced by special machine tool, which ensures concentricity among shaft bearing, shaft and pump case, and provides better reliability and maintainability. Apply to municipal water supply and drainage, water circulation of air conditioner, agricultural hydraulic engineering, such as irrigation, drain flooded fields etc., industrial water supply system, firefighting system, water supply and drainage of
heating system, transportation of clean water

4. OPERATING CONDITION

a)Rotate speed: 2950r/min, 1480 r/min, 980 r/min, 730 r/min
b)Flow range: 64.4~9810m3/h
c)Delivery lift: =200m
d)Medium temperature: =80 ,
e)product adopting special materials: -20 ~120
f)Ambient temperature: Lower than 40
g)Operating pressure up to achieves 2.5MPa

5. MATERIAL 

a)Pump casing: Cast iron or magnesium iron
b)Pump cover: Cast iron or magnesium iron
c)Impeller: Cast iron, magnesium iron or tin bronze
d)Sealing ring: Cast iron or tin bronze
e)Pump shaft: 45# steel plated with chrome
f)Dynamic and static mechanical sea: Hard carbide, graphite
g)Configuring other material according to requirement is allowable

Rated flow

10(m3/h)

Rated head

26m

Rated power

1.5Kw

Voltage

220V

Rated Current

7.2A

Rated speed

2860r/min

Discharge diameter

50mm

6.Conditions of use

Pumps used in the following conditions should be continuously to work properly: 
1. For water pumps suitable medium, medium temperature shall not exceed + 40°C
2. The medium PH value between 6.5 ~ 8.5 
3. The volume of medium containing solid impurity is less than 0.1%, the size is not more than 0.2 mm 
4. The power frequency 50 hz, voltage for single-phase 220 v, 380 v, three-phase voltage fluctuation range for rating of 0.9 to 1.1 times 
5. Diving depth of no more than 5 m, is not suitable for irrigation and drainage of sewage and chemicals.

Water Pump Made In China Good Quality On Sale

Water Pump Made In China Good Quality On Sale


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to select the pump model?
Your vertical height is approximately equal to 190 meters, the actual line loss should be considered to be more than 200 ~ ~!How much do you need for traffic?Choose a suitable submersible deep well pump according to the flow rate! You can communicate in private!
Q:Yang Chengtai big, the pump power is too small, the water pump will be bad?
Related to water pump structure, when the pump head is higher than the rated pump head, the current will increase, the water discharged from the pump impeller, back to the inlet of water from between the impeller and the casing exceeds the rated value, if it is a high lift pump, clearance between the impeller and the casing is small, the water pump current increases with increasing lift, current too much faster than the rated value, the motor will burn; if it is a low lift pump design, when the clearance between the impeller and the casing of the strict requirements, and even some of the water pump, the outlet is blocked, the pump will not burn. The drinking water pump used on the table, generally used non-toxic latex diaphragm pump, the head is too much, will damage the diaphragm part, the motor because the circuit has protection, the motor is not easy to damage. Generally do not risk good, according to the actual situation, select the appropriate lift, suction pump.Yang Chengtai large! If the pump power is too small! The pump will break! But not necessarily bad, mainly determined by the pump structure.
Q:The role of impeller in water pump
The impeller rotates at high speed so that the centrifugal force is generated by the water, and the vacuum is generated in the middle of the impeller, and the water source is continuously sucked into the impeller to increase the kinetic energy of water and play a role in promoting water.
Q:What motor does the pump use?
Pump should use special water pump motor.Pump motor (pump motor) according to the structure classification, should be divided into horizontal motor and vertical motor. Because of the work characteristics of pump starting torque is relatively small, the starting frequency is relatively small, relatively long time continuous operation and other characteristics, so the majority of pump motor asynchronous motor cage rotor or synchronous motor.
Q:Is there a water pump with its own flow regulating function?
It has a water pump with adjustable flow capacity, I used it. Can also landing professional production pump manufacturers web site inquiries.
Q:Water pump is not Sheung reason
The problem you are experiencing is stressThe above answer is only considered in the case of water absorptionJust imagine, two pumps are normal work, the same suction pipe, how can there be dissatisfaction with water or vacuum state?.According to my experience analysisYour system is three sets of parallel, lift and flow should be the same, if not the same, not in this discussion, the topic should be set up.Lift is the same, that is, in two or three units at the same time, the resulting system pressurization is the same, and water will increaseBut now your traffic is increasing at two units, but it will not increase at threeYou have selected pipeline system design, in the design of head flow under single condition is constant, if the increase in open water pump, the pressure is constant, increasing water content, according to the continuity equation Q = A X V, then the flow velocity in the tube will increase;But when the third pumps, 2Q becomes 3Q, normally velocity should be larger, but the Darcy formula shows that the velocity increases, extension resistance and local resistance will be increased, and the double square, so you can open third pumps for reasoning, when the resistance effect caused by the pipeline the increase of water flow in the pipeline can not be reused, the general formula of constant current, now the whole pipeline in turbulent stateThat is, third pumps to do the work in the water and pipe wall friction in the loss, and actually did not play a role in water supplyThe solution is to increase the flow rate by increasing the water supply pipeline
Q:What is the function of boiler feed pump, condensate pump, vacuum pump and low drain pump in operation?
The feed pump is a pump for supplying water to the boiler and maintaining the water level of the boiler. The condensate pump provides water to the deaerator after condensing the turbine and provides water for some condensate users. Vacuum pump is to maintain the vacuum of the pump, the pump is to lower the drain in a timely manner to the next level of low pump
Q:How can the pump be stationary?
Rusty, turn with your hands to see the situation, the two bearings filled with lubricating oil.
Q:What's the function of the engine pump?
In simple terms, the engine is cooled to prevent the engine from getting too high.Working principle:Drive the pump bearings and the impeller to rotate through the pulley, the coolant pump impeller is driven to rotate together, under the action of centrifugal force was thrown to the edge of the pump shell, and produce a certain pressure, and then from a channel or pipe outflow. At the center of the impeller, the pressure is lowered because the coolant is thrown out, and the coolant in the water tank is sucked into the impeller by the water pipe and the pressure difference between the inlet of the impeller and the center of the impeller to realize the reciprocating circulation of the cooling liquid.
Q:Fully automatic self-priming pump
Yes, add a water level controller.Try electronic water level switch with stable and reliable performance. In Baidu search "electronic water level switch official website", you can find more information, model is BZ201

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range