Product Description:

1.Specifications

1)High performance
2)Mechanical seal
3)Cast iron impeller or bronze impeller
4)Lower vibration water pump
5)Large flow

2.Packaging & Delivery

Packaging Detail:

export wooden cases

Delivery Detail:

within 30 days once receipt of 30% T/T prepayment

BPO Irrigation Centrifugal Split Water Pump

3.FEATURES

BPO series single-stage double-suction open type centrifugal pump self-researched by the Company after absorbed advanced technology of similar products and combined application requirement of various customers. The series pump adopts excellent hydraulic model, wider type spectrum and better structure. Pump casing is produced by special machine tool, which ensures concentricity among shaft bearing, shaft and pump case, and provides better reliability and maintainability. Apply to municipal water supply and drainage, water circulation of air conditioner, agricultural hydraulic engineering, such as irrigation, drain flooded fields etc., industrial water supply system, firefighting system, water supply and drainage of
heating system, transportation of clean water

4. OPERATING CONDITION

a)Rotate speed: 2950r/min, 1480 r/min, 980 r/min, 730 r/min
b)Flow range: 64.4~9810m3/h
c)Delivery lift: =200m
d)Medium temperature: =80 ,
e)product adopting special materials: -20 ~120
f)Ambient temperature: Lower than 40
g)Operating pressure up to achieves 2.5MPa

5. MATERIAL 

a)Pump casing: Cast iron or magnesium iron
b)Pump cover: Cast iron or magnesium iron
c)Impeller: Cast iron, magnesium iron or tin bronze
d)Sealing ring: Cast iron or tin bronze
e)Pump shaft: 45# steel plated with chrome
f)Dynamic and static mechanical sea: Hard carbide, graphite
g)Configuring other material according to requirement is allowable

Rated flow

10(m3/h)

Rated head

26m

Rated power

1.5Kw

Voltage

220V

Rated Current

7.2A

Rated speed

2860r/min

Discharge diameter

50mm

6.Conditions of use

Pumps used in the following conditions should be continuously to work properly: 
1. For water pumps suitable medium, medium temperature shall not exceed + 40°C
2. The medium PH value between 6.5 ~ 8.5 
3. The volume of medium containing solid impurity is less than 0.1%, the size is not more than 0.2 mm 
4. The power frequency 50 hz, voltage for single-phase 220 v, 380 v, three-phase voltage fluctuation range for rating of 0.9 to 1.1 times 
5. Diving depth of no more than 5 m, is not suitable for irrigation and drainage of sewage and chemicals.

Water Pump Centrifugal  Good Quality Made In China

Water Pump Centrifugal  Good Quality Made In China


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Can centrifugal pumps be idle? What's the status of the empty transfers?
The centrifugal pump can not be idle, idle will wear packing (packing seal, mechanical seal is almost not damaged) parts, also caused the seal ring, seal, etc. the balance disc wear quickly, and the temperature will rise sharply, causing damage; air transfer effects caused by transient overload voltage of the motor is large, if the motor can not automatically jump to motor will burn.Centrifugal pump mostly rely on the delivery of liquid lubrication and cooling seal of centrifugal pump, idling is empty load, is to open the inlet valve, close the exit valve operation can move, try reversing or empty load operation should be based on the inevitable time, pump specification shall prevail.
Q:Water pump motor often inlet
I don't know what the pump is upstairsThe ordinary centrifugal pump inlet outdoor installation, in order to prevent the motor fan end can be installed in the end of 0.5 with the maple leaf canopy, the sheet can be, the supporting leg can be installed in the wind leaf cover screws; if your motor output is water, and the output end of the motor bearing can be installed with the same motor shaft the outer diameter of the rubber water retaining ring (the market for rubber seal should be easy to buy)Submersible pump (pump) often water, you should consider replacing the good points of the mechanical seal, such as to choose oil resistant, acid and alkali resistant, selected according to the transmission medium and the pump itself, if you can confirm the correct, check whether the pump shaft bending, made into concentric mechanical seal damage. And check whether the casting on the motor side is defective or not;Choose a higher level of protection of sewage pump, preferably in the pump leakage probe, float switch, overload, lack of protection, generally will not burn the motor
Q:What is the reason that the water supply of pump is getting smaller?
1, the water pump screen plug, should remove the filter screen sundries.2, the use of lift is too high. Over the pump range, the pump should be adjusted to use height or replace the pump head.3, pump impeller plug or wear, should remove the impeller sundry. Replace the impeller if worn.4, pump outlet pipe blocked by debris, should remove the debris in the pipe outlet.5, diameter and pump does not match, replace the outlet pipe.6, the pump cover gap is too large, increased pump volume loss, should adjust the gap.7, pump body and pump cover leakage, should tighten the pump cover screw, make the pump body and pump cover close coordination.8, the pump speed is low, the use of voltage is too low. Should adjust the voltage to the rated value, replace the thicker cable or avoid peak use.9, water pump diving depth is too shallow, there is air intake, should adjust the diving depth. Pump running depth is not less than 0.5 meters.Yi Mai water pump to help you answer, I hope to help you
Q:Power flow conversion of water pump
Upstairs in Wurenzidi, pump power is related to the flow and the head, a simple formula: = /367 * power flow lift efficiency
Q:Water pump 50HZ impeller and 60HZ what is different, why not the same?
60Hz pump and 50Hz pump itself is not much difference, just that the motor speed, the rated speed is 3600 rpm, 1200 rpm, 1800 rpm, the latter is generally 3000, 1500, 1000 etc.. If it is to use the same pump, the difference is that the 60Hz motor pump flow is 50Hz, motor water pump flow of 1.2 times, the lift is 1.2*1.2=1.44 times, power is 1.2*1.2*1.2=1.728 times. So in the actual manufacture, especially some relatively large flow lift pumps, pump motor using 60Hz to use 50Hz thicker than the spindle motor of the pump impeller, the difference between the two, in addition to empty size shaft is different, what basically no difference. As for the data of package angle, the water conservancy models of different factories are different, but I don't know whether there is any difference between them. Most of them make no difference. However, if you want to use the 60Hz pump to achieve the same flow rate as the 50Hz pump, the impeller of the former should be cut to 0.833 times the size of the latter.
Q:Water pump eliminates air
First of all, why should exhaust air, pump suction principle is the rotation of the impeller, pump water inside the throw out, and then let the inlet pipe into a vacuum. Then, under the influence of atmospheric pressure, the water pressure is pumped into the pump. Therefore, if the water is not filled, the sealing of the pump is impossible to pump the air inside the evacuation of high vacuum. In other words, do not fill the water, you can not smoke water. You can hear the noise in the pump when the water bubbles under the bottom vacuumThe water doesn't go up because it doesn't have enough vacuum!The reason 1 is because there is no water filling,2, because your pump and water vertical height higher than the pump itself suction stroke.3., the pipeline resistance is too large (including the pipe diameter is too small, elbow and so on)
Q:50 meters deep well with what water pump: home?
What types of household water pump, self-priming pump, centrifugal pump, submersible pump, according to the size and utility of water pump, self suction pump is the advantage of direct water, normal household to 1500 watts can, but must keep the water clean, water there can be no silt or small sand. Centrifugal pump need drinking water, that is not self suction;But the advantage is a large amount of water. When used, the power will be reduced, because the use of centrifugal switch is automatically disconnected, energy savings can be used, the general household on these two, as for submersible pumps, home generally less than.
Q:How much is the flow rate of fire hydrant and spray shared water pump?
Fire fire water is superimposed, at the minimum, the lowest 5L/S automatic spraying fire hydrant, light danger level 13.9L/S, the least is 18.9L/S, but the data is useless, the data are not spraying fire hydrant, concrete analysis of high-rise buildings like the dangerous level according to the calculation, the general design, the concrete building needs the high-rise building minimum 20L/S, automatic spraying dangerous level according to the general 30L/S, 50L/S need to flow.Fire hydrant: fire hydrant (English Name: fire hydrant), a stationary fire fighting tool, with 4 iron chains. Fire hydrants are provided throughout the city to provide fire water for firefighters during the rescue. The main function is to control fuel, insulate combustion and eliminate fire source. The fire fighting system includes outdoor fire hydrant system, indoor fire hydrant system, fire extinguisher system, and some automatic sprinkler system, water gun system, gas fire extinguishing system, fire detection system, water mist system and so on. Hydrants are mainly fire engines from the municipal water supply network or outdoor fire water supply network to implement fire fighting, but also can directly connect hoses, water cannons, fire extinguishing. Therefore, the outdoor fire hydrant system is also one of the important fire fighting facilities.
Q:What is the 10KV pump unit?
10KV should refer to the motor start voltage value, ultra high voltage start, the general pump more than 160KW of the motor, the voltage used in 6KV, you motor should be more than 300KW
Q:Water pump mutual switching device
Now fire control cabinet has several requirements, multi-channel start, failure switch, automatic inspection, etc.Failure switching is when the main pump fails to start, the standby pump is put into operation automatically (and the two pumps are alternate).Mutual investment due to the original selection of different electrical principle is slightly different, but the same is the control of the main contactor, the main contactor when the main pump without electricity and suction time, time relay (or PLC fault detection delay is given by the pump start signal delay conversion) pump operation.You'd better find a fire drawing study.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range